text

,

Commonwealth Edison

-O Dresden Nucle r P:wer St1 tion qj " R.R. #1 Morris, lilinois 60450 Telephone 815/942-2920 July 21, 1982 DJS LTR: #82/806 James G. Keppler, Regional Administrator Directorate of Regulatory Operations Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Reportable Occurrence Report #82-25/03L-0, Docket #050-237 is being submitted to your office in accordance with Dresden Nuclear Power Station Technical Specification 6.6.B.2.(b), conditions leading to operation in a degraded mode permitted by a limiting condition for operation or plant shutdown required by a limiting condition for operation.

b. @

D. J. ScotV &

Station Supck.Intendent Dresden Nuclear Power Station DJS:mb Enclosure cc: Director of Inspection & Enforcement Director of Management Information & Program Control U. S. NRC, Document Management Branch File /NRC i

i i

I i

I' 8208090228 820721 2%

l PDR ADOCK 05000237 )(jG

[ S PDR .._ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ . . _ _ _ _ _ _ _ .gg g 3

DEVIATION REPORT Commonwealth Edison gy, K3, ,

M , uNff , MAR NN PART Il TITLE OF DEVI ATION OCCURRED LPCI Suction Valve (M02-1501-5D) Failure To Open 7/1/82 1915 SYSTEM AFFECTE PL ANT STATUS AT TIME OF EVENT TESTING 1500 LPCI u0DE RUN PARiunT) 2330 761

, , t0A0iuAE3 hs CESCRIPTION OF EVENT During LPCI Valve Operability Testing, LPCI suction valve M02-1501-5D failed to reopen following closure. Breaker racked out and racked back in. Valve manually moved off seat and electrically would still not open. Manually reopened suction valve and EM's notified to investigate.

10 CFR50.72 NRC RED PHONE NOTIFICATION MADE YES NO EQUIPMENT F A ILURE D21387 Oves NO *0Rx REQUEST NO. RESPONSIBLE SUPERVISOR Bob Herbert nArt 7/1/82 PART 2 l 0PERA TING ENGINEER'S C0hedENTS Electricians cleaned aux. contacts in breaker, and valve operated properly.

EVENT OF PUBLIC INTEREST 24= HOUR NRC NOTIFICATION RE0'D TECH. SPEC. VIOLATION TELEPH _

REGION lil CATE TIME NON REPORTABLE OCCURRENCE TELECM/TELECOPY O 14 DAY REPO R TA BL E/ T. S . REGION lil CATE TIME h 30 DAY R EP O R TA BL E / T. S . 6 . 6. B . 2 . b ANNUAL /SPECL REPORT RE0'D IF ABOVE NOTIFICATION IS PER 10CFR21 A.I.R. s S. DAY WRITTEN REPORT RE0'D PER 10CFR2?

' E 8- ,82-25/03L-0 7 pg i. A. Palmer 7/2/82 1543 CECO CORPORATE OFFICER DATE TIME PRELIMINARY REPORT John M. Almer 2!O COMPLETED AND REVIEWED OPER ATING ENGINEER , DAW e INVESTIGATED REPORT & RESOLUTION ACCE P TED BY STATION REVIE# \. b w _a. .

m l V 1 ui gn (_ / h/J 4 /f b RESOLUTION APPROVED AND  % .arrw \ N AUTHORI ZED FOR DI STR I BUTION 44*St?6 (FORM 15.$2-11 STATION SUP I N TENDENT DATE 10*St

. . . . _ . . _ _ _ . . . . _ - - ----~-.v-- .

~ __

_ . - . _ _ - _ -