The following pages link to 05000416/LER-1982-028, Forwards LER 82-028/01T-0:
Displayed 42 items.
- ML20063J563 (redirect page) (← links)
- 05000416/LER-1982-028 (redirect page) (← links)
- 05000416/LER-1982-143, Forwards LER 82-143/03L-0 (← links)
- 05000416/LER-1982-125, Forwards LER 82-125/03L-0 (← links)
- 05000416/LER-1982-126, Forwards LER 82-126/99L-0 (← links)
- 05000416/LER-1982-110, Forwards LER 82-110/03L-0 (← links)
- 05000416/LER-1982-118, Forwards LER 82-118/03L-0 (← links)
- 05000416/LER-1982-119, Forwards LER 82-119/03L-0 (← links)
- 05000416/LER-1982-077, Forwards LER 82-077/01T-0 (← links)
- 05000416/LER-1982-147, Forwards LER 82-147/99X-0 (← links)
- 05000416/LER-1982-108, Forwards LER 82-108/99L-0 (← links)
- 05000416/LER-1982-113, Forwards LER 82-113/03L-0 (← links)
- 05000416/LER-1982-124, Forwards LER 82-124/03L-0 (← links)
- 05000416/LER-1982-121, Forwards LER 82-121/03L-0 (← links)
- 05000416/LER-1982-117, Forwards LER 82-117/03L-0 (← links)
- 05000416/LER-1982-094, Forwards LER 82-094/03L-0 (← links)
- 05000416/LER-1982-100, Forwards LER 82-100/03L-0 (← links)
- 05000416/LER-1982-186, Forwards LER 82-186/99X-0 (← links)
- 05000416/LER-1982-182, Forwards LER 82-182/03L-0 (← links)
- 05000416/LER-1982-177, Forwards LER 82-177/03L-0 (← links)
- 05000416/LER-1982-159, Forwards LER 82-159/03L-0 (← links)
- 05000416/LER-1982-155, Forwards LER 82-155/03L-0 (← links)
- 05000416/LER-1982-158, Forwards LER 82-158/99L-0 (← links)
- 05000416/LER-1982-157, Forwards LER 82-157/03L-0 (← links)
- 05000416/LER-1982-135, Forwards LER 82-135/99X-0 (← links)
- 05000416/LER-1982-141, Forwards LER 82-141/99X-0 (← links)
- 05000416/LER-1982-133, Forwards LER 82-133/03L-0 (← links)
- 05000416/LER-1982-138, Interim LER 82-138/99X-0:on 821112,during Shutdown,Several Duct Covers Could Not Be Installed Due to Cables Extending Through Ducts.Caused by Faulty Design Document.Engineering Evaluation Underway (← links)
- 05000416/LER-1982-140, Forwards LER 82-140/99X-0 (← links)
- 05000416/LER-1982-070, Forwards LER 82-070/03L-0 (← links)
- 05000416/LER-1982-166, Forwards Updated LER 82-166/99X-1 (← links)
- AECM-82-382, Forwards Responses to 820826 Request for Addl Info Re Items 1-8,including Current Status & Submittal Schedule for Outstanding Items.Tf Plunkett Prof Qualifications Encl (← links)
- 05000416/LER-1982-156-03, While Performing Surveillance Test 06-OP-1P75-M-0002,Div II Diesel Failed to Start.Caused by Personnel Error.Fuel Leaks Due to Loose Bleed (Vent) Plugs.Plugs Tightened (← links)
- 05000416/LER-1982-172-99, Penetration AE154C in Auxiliary Bldg Opened to Perform Planned Maint.Penetration Opened to Pull Cable Through.Limiting Condition for Operation Initiated & Hourly Fire Watch Established (← links)
- 05000416/LER-1982-065-03, /03L-0:on 820907,smoke Detectors in Fuel Handling Area & Main Steam Tunnel Alarmed & Would Not Clear.Caused by Dust Accumulation on Ionization Smoke Detector.Detectors Cleaned (← links)
- 05000416/LER-1982-126-99, /99L-0:on 821026,several Fire Dams & Penetration Seals Broken While Replacing Shorted Cable Running from Control Room to Computer Room.Fire Dams Restored.Work Still Progressing on Penetration Seals.Update by 830202 (← links)
- 05000416/LER-1982-103-01, Failure to Demonstrate Operability of Remaining Ac Power Sources Discovered During Review of Documentation Declaring Hpcs,Div III Diesel Generator Inoperable.Caused by Personnel Error (← links)
- 05000416/LER-1982-028-01, /01T-0:on 820814,Halon Sys Surveillance Test Revealed That Acceptance Criteria for Change Pressure of Halon Bottles Not Met.Caused by Surveillance Test Performed Prior to Issuance of Ol.Halon Bottles Replaced (← links)
- 05000416/LER-1982-004-03, /03L-0:on 820616,prior to Initial Fuel Load,Area Radiation Monitoring Sys Failure Alarm Initiated.Probably Caused by Transient Which Allowed Meter to Fall in Downscale Range of Monitor.Sys Tested & Declared Operable (← links)
- 05000416/LER-1982-003-03, /03L-0:on 820616,during Surveillance Testing, Output Amplifiers for free-field Forced Balanced Accelerometer Found Inoperable.Probably Caused by Lightning Damage.Amplifiers Replaced & Surveillance Test Completed (← links)
- 05000416/LER-1982-002-01, /01T-0:on 820701,two Scrams Initiated by High Flux Spikes on Fuel Loading Chambers Connected to Source Range Monitor Noncoincident Reactor Protection Sys Logic.Probably Caused by Close Proximity of Fuel Bundles to Fuel Chamb (← links)
- 05000416/LER-1982-001-01, /01T-0:on 820618,loss of Dc Power to Div II Diesel Generator Control Circuit Detected.Caused by Failure of Main Fuses to Dc Control Panel Due to Fault in Circuitry of Semiconductor Annunciator module,SAM-2.Module Bypassed (← links)