Pages that link to "05000289/LER-1981-006, Forwards LER 81-006/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000289/LER-1981-006, Forwards LER 81-006/03L-0:
Displayed 50 items.
- ML20039E263 (redirect page) (← links)
- 05000289/LER-1981-013, Forwards LER 81-013/01T-0 Re Leaking Found in Steam Generators.Event Reportable Per Tech Spec 6.9.2.A(3). Supporting Documentation Encl (← links)
- 05000320/LER-1981-009, Has Been Canceled (← links)
- 05000320/LER-1981-031, Has Been Canceled (← links)
- 05000320/LER-1981-011-01, /01P-0:on 810423,nuclear Svcs River Water Pump NR-P-1A Was Declared Inoperable.Pump Cannot Be Repaired within Time Allowed by Tech Spec Due to Unavailability of Spare Parts.Details to Follow (← links)
- 05000320/LER-1981-038-01, /01L-0:on 811228,wind Direction & Wind Speed Monitoring Instruments on Meteorological Tower Became Inoperable Due to Ice Formation.Instruments Deiced Naturally.Util Awaiting Instrument Jacket Heaters Delivery (← links)
- 05000320/LER-1981-038, Forwards LER 81-038/01L-0 (← links)
- 05000320/LER-1981-034-01, /01L-0:on 811201,incore Thermocouple F-12 Declared Inoperable.Circuitry Problem Identified & Corrected.Caused by Reversed Polarity.Surveillance Procedure 4302-R4 Amended to Require post-surveillance Evaluation (← links)
- 05000320/LER-1981-034, Forwards LER 81-034/01L-0 (← links)
- 05000289/LER-1981-011, Updated LER 81-011/01T-1:on 811019,determined That Catwalk Structure,Used to Support Cable Trays,Conduit & Terminal Blocks for Control Consoles Did Not Meet Seismic Criteria. Caused by Ae Failure to Perform Calculations (← links)
- 05000289/LER-1981-010-03, QC Audit Showed One of 21 Reactor Bldg Prestressing Tendons Inspected During 1980 Surveillance Had Low Liftoff Force.Caused by Use of Incorrect Calibr Data.Procedure Being Rewritten (← links)
- 05000320/LER-1981-037-03, /03L-0:on 811217,high Motor Bearing Temp Alarm Annunciated in Control Room for Nuclear Svc River Water Pump NR-P-1B.Caused by Failure of Lower Motor Bearing.Motor Replaced.Investigation Continuing (← links)
- 05000320/LER-1981-037, Forwards LER 81-037/03L-0 (← links)
- 05000320/LER-1981-036-01, /01L-0:on 811214,wind Direction Monitoring Instrument Became Inoperable Due to Ice Formation.Caused by Adverse Weather.Monitor Deiced Naturally Because Hazardous Conditions Precluded Immediate Corrective Action (← links)
- 05000320/LER-1981-036, Forwards LER 81-036/01L-0 (← links)
- 05000289/LER-1981-014-01, /01T-0:on 811223,during IE Bulletin 79-02/14 Insps of Pipe Supports,Nine Structural Interfacing Areas Were Identified as-built in Nonconformance to Original Design Areas in Final Stages of Mod.Reanalysis Initiated (← links)
- 05000289/LER-1981-014, Forwards LER 81-014/01T-0 (← links)
- 05000320/LER-1981-035-03, /03L-0:on 811201,wind Direction Monitoring Instrument in Meteorological Tower Became Inoperable Due to Ice Formation.Caused by Adverse Weather.Instrument Deiced (← links)
- 05000320/LER-1981-035, Forwards LER 81-035/03L-0 (← links)
- 05000320/LER-1981-016-01, /01P Has Been Cancelled (← links)
- 05000320/LER-1981-014-03, /03L-0:on 810507,corrosion Noted on Battery Terminals of Diesel Fire Pump.Caused by Failure to Perform or Reschedule Surveillance Since Sept 1977 Due to Error in Computer Entry (← links)
- 05000320/LER-1981-014, Forwards LER 81-014/03L-0 (← links)
- 05000289/LER-1981-006-03, /03L-0:on 810507,corrosion on Diesel Fire Pump Battery Terminals Noted.Caused by Failure to Include Surveillance in Computer Tracking Sys.Surveillance Entry Into Computer Data Base Verified (← links)
- 05000289/LER-1981-006 (redirect page) (← links)
- 05000320/LER-1981-033-01, /01L-0:on 811113,once-through Steam Generator Level Indication B Failed.Caused by 12-volt Dc Power Supply for Transmitter Failure.Power Supply Replaced (← links)
- 05000320/LER-1981-033, Forwards LER 81-033/01L-0 (← links)
- 05000320/LER-1981-030-01, /01L-0:on 811030,eight Containment Penetration Isolation Valves Found Open W/O Control Per Tech Specs. Caused by Lack of Proper Administrative Procedures. Procedures Developed (← links)
- 05000320/LER-1981-030, Forwards LER 81-030/01L-0 (← links)
- 05000289/LER-1981-012-04, /04L-0:on 811116,ETS 2.2.1.a,limiting Condition for Riverwater Chlorination,Was Exceeded.Caused by Malfunctioning Timing Device.Faulty Timer Repaired.Tech Spec Change Request 100A Allows Condition to Equal NPDES Permit (← links)
- 05000289/LER-1981-012, Forwards LER 81-012/04L-0 (← links)
- 05000320/LER-1981-029-01, /01L-0:on 811028 Discovered That Failure of Nitrogen Supply Regulator Valve Could Overpressurize SDS Vessel & Cause Rupturing.Original Design Inadequate When Gas Supply Changed.Pressure Relief Valve Inserted (← links)
- 05000320/LER-1981-029, Forwards LER 81-029/01L-0 (← links)
- 05000289/LER-1981-005-99, /99X-0:on 810122,cumulative Reactor Utilization Factor Was Determined Not to Meet Newly Amended Tech Spec. Caused by Amending Tech Specs W/O Verifying Record.Tech Spec Will Be Changed (← links)
- 05000320/LER-1981-028-01, /01L-0:on 811014,auxiliary Bldg Exhaust Flowrate Decreased Approx 7000 Cfm.Caused by One of Two Vortex Dampers on Each Exhaust Fan (AH-E-8A & 8B) Failing to Close. Dampers Repaired (← links)
- 05000320/LER-1981-028, Forwards LER 81-028/01L-0 (← links)
- 05000320/LER-1981-023-03, /03L-0:on 810911,during NRC Insp,Discovered Control Bldg Charcoal Filters Were Tested to Inadequate Acceptance Percentage.Caused by Reg Guide Misunderstanding & Confusion Re Various Regulations.Revising Tech Specs (← links)
- 05000320/LER-1981-023, Forwards LER 81-023/03L-0 (← links)
- 05000289/LER-1981-010, Forwards LER 81-010/03L-0.Detailed Event Analysis Encl (← links)
- 05000320/LER-1981-027-03, /03L-0:on 811007,during Annual Surveillance of Firewall-50 Seals,Some Seals Found Deficient.Caused by Cracks Which Developed in Fire Barrier Penetrations Due to Dehydration of Barriers.Cracks Repaired (← links)
- 05000289/LER-1981-011-01, /01L-O:on 811019,catwall Structure Used to Support Cable Trays,Conduit & Terminal Blocks for Control Consoles Determined Inadequately Designed for Seismic Loads. Caused by Lack of Seismic Design Calculations by Ae (← links)
- 05000320/LER-1981-025-03, /03L-0:on 810914,during Fire Barrier Penetration Fire Seal Insp,Three Penetrations Found Unsealed.Caused by Inadequate Controls to Ensure Resealing of Penetrations Following Maint or Const (← links)
- 05000320/LER-1981-025, Forwards LER 81-025/03L-0 (← links)
- 05000320/LER-1981-022-03, /03L-0:on 810909,surveillance Procedure for Channel Calibr of Gas Partitioner Performed After Scheduled Calibr Expiration Date.Caused by Manpower Load for Unit 1 Nonfunctional Tests & Foreman Unfamiliar W/Procedures (← links)
- 05000320/LER-1981-022, Forwards LER 81-022/03L-0 (← links)
- 05000320/LER-1981-021-03, /03L-0:on 810907,manual Inlet Damper to Control Room Bypass Supply Fan Failed Closed During Control Room Emergency Ventilation Performance Analysis.Caused by Loose Set Screw on Manual Actuation Control Arm (← links)
- 05000320/LER-1981-021, Forwards LER 81-021/03L-0 (← links)
- 05000289/LER-1981-009-01, /01T-0:on 810117,emergency Diesel Generator Feeder Breaker Logic Anomaly Discovered Which Could Result in Damaged Motor or Generator End Turns & Excessive Voltage Dip on Diesel Generator.Caused by Design Error (← links)
- 05000289/LER-1981-009, Forwards LER 81-009/01T-0 (← links)
- 05000320/LER-1981-026-03, /03L-0:on 810902,auxiliary Bldg Ventilation Sys Was Inoperable.Caused by Broken Linkage in Vortex Damper. Damper Repaired,Tested & Returned to Svc (← links)
- 05000320/LER-1981-026, Forwards LER 81-026/03L-0 (← links)