Pages that link to "05000269/LER-1982-007, Forwards LER 82-007/01T-0.Detailed Event Analysis Encl"
Jump to navigation
Jump to search
The following pages link to 05000269/LER-1982-007, Forwards LER 82-007/01T-0.Detailed Event Analysis Encl:
Displayed 50 items.
- ML20054L863 (redirect page) (← links)
- 05000269/LER-1982-007 (redirect page) (← links)
- 05000287/LER-1982-008, Forwards LER 82-008/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-005, Forwards LER 82-005/03L-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-014, Forwards LER 82-014/03L-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1982-010, Forwards LER 82-010/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-015, Forwards LER 82-015/03L-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-012, Forwards LER 82-012/03L-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1982-014, Forwards LER 82-014/01T-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1982-015, Forwards LER 82-015/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-017, Forwards LER 82-017/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-011, Forwards LER 82-011/03L-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-010, Forwards LER 82-010/01T-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-009, Forwards LER 82-009/03L-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-013, Forwards LER 82-013/01T-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1982-007, Forwards LER 82-007/01T-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1982-012, Forwards LER 82-012/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-016, Forwards LER 82-016/01T-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-013, Forwards LER 82-013/03L-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-012, Forwards LER 82-012/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-012-01, /01T-0:on 820623,both Trains of Reactor Bldg Spray Inoperable Due to Train B Pump Out of Svc While Train a Pump Suction Valve Was Shut.Caused by Personnel Error.Train B Pump Racked in Pump Breaker (← links)
- 05000287/LER-1982-012-01, /01T-0:on 821117,steam Generator Tube Leak of 0.5 Gpm Indicated by Condensate Steam Air Ejector Offgas Radiation Monitor.Caused by Cracks in Tubes 65-1,68-4,78-4, 78-8 & 83-5.Tubes Removed from Svc for Lab Analysis (← links)
- 05000269/LER-1982-016-01, /01T-0:on 821018,internal QA Audit Revealed That Engineering Safeguards Surveillance Tests Not Performed During Jan 1982.Caused by Administrative Deficiencies & Personnel Error.New Sys Established & Personnel Counseled (← links)
- 05000270/LER-1982-013-03, /03L-0:on 821005,turbine-driven Emergency Feedwater Pump Declared Inoperable When Trip/Throttle Valve 2MS-94 Accidentally Tripped Closed by Maint Personnel While Insulating Valve.Caused by Component Failure (← links)
- 05000269/LER-1982-014-03, /03L-0:between 820816-0920,reactor Bldg Cooling Unit Fan 1A Tripped on Low Speed Thermal Overloads Seven Times.Cause Unknown.Fan Under Surveillance.Fan Motor May Be Replaced If Cause of Trips Cannot Be Determined (← links)
- 05000287/LER-1982-010-01, /01T-0:on 821004,discovered That Weekly Boron Waste Storage Tank Boron Sample Not Taken as Scheduled, Contrary to Tech Spec 4.1.3.Caused by Personnel Not Having Access to Posted Schedule Board.Board Replaced (← links)
- 05000269/LER-1982-015-03, /03L-0:on 820917,reactor Protection Sys Trip Pushbutton Declared Technically Inoperable.Caused by Procedure Deficiency Which Did Not Include Required Test. Necessary Procedures Changed (← links)
- 05000270/LER-1982-012-03, /03L-0:on 820916,turbine Driven Emergency Feedwater Pump Declared Inoperable When Trip/Throttle Valve 2MS-94 Discovered Tripped in Closed Position.Cause Not Known.Valve Reset.Video Alarm Will Be Repaired (← links)
- 05000287/LER-1982-014-01, /01T-0:on 821211,steam Generator Tube Leak Indicated by Condensate Steam Air Ejector Offgas Radiation Monitor.Caused by Crack in Tube 77-9.Tube 77-9 & Tube 78-2 Removed from Svc (← links)
- 05000287/LER-1982-015-01, /01T-0:on 821212,manual Containment Isolation Valves 3IA 90 & 91 Found Open,Violating Containment Integrity.Caused by Personnel & Procedure Error.Personnel Counseled & Procedure Revised (← links)
- 05000269/LER-1982-017-01, /01T-0:on 820820,station I&C Batteries 1CA,1CB & 3CA Declared Inoperable Due to Failure to Take Corrective Actions on Deficiencies Identified During Monthly Surveillance.Caused by Personnel Error (← links)
- 05000269/LER-1982-011-03, /03L-0:on 820622,while Testing to Verify Unit Operability,Unit Would Not Close Into Sys Grid Via Keowee to 230-kV Switchyard Tie Breaker (ACB-1).Caused by Leaking Float Valve in Turbine Governor Control Sys (← links)
- 05000270/LER-1982-010-01, /01T-0:on 820722,while Investigating Erroneous Instrument Readings,Upper Surge Tank Water Level Found to Be Less than 5 Ft.Caused by Stuck Suction Relief Valve on Main Feedwater Pump 2B.Valve Reseated.Instrumentation Repaire (← links)
- 05000270/LER-1982-009-03, /03L-0:on 820616,valve 2FDW-316 Would Not Open Fully.Valve Declared Inoperable,Making Emergency Feedwater Flowpath 2B Inoperable.Apparently Caused by Valve Manual Handwheel Being Partially Shut.Handwheels to Be Locked Open (← links)
- 05000269/LER-1982-013-01, /01T-0:on 820706,emergency Feedwater Initiation Logic Pressure Switches Determined Not Surveillance Tested from 820523-0708,rendering Pumps Inoperable.Caused by Inadequate Review of Tech Spec Change.Tests Performed (← links)
- 05000287/LER-1982-007-01, /01T-0:on 820521,during Video Insp of Fuel Assemblies,Broken Holddown Springs Found on Fuel Assemblies NJ001MH & NJ001M9.Caused by Fatigue Induced Cracking at Existing Surface Flaw.Springs Will Be Replaced (← links)
- 05000287/LER-1982-008-01, /01T-0:on 820609,during Removal of Locking Clips on Thermal Shield bolts,19 of 27 Bolts Had Bolt Heads Broken Off.Upon Completion of Locking Clip removal,46 of 96 Had Heads Broken Off.Caused by Stress Cracking (← links)
- 05000269/LER-1982-007-01, /01T-0:on 820616,during Periodic Environ Surveillance,Keowee Hydro Station Water Fire Suppression Sys Declared Inoperable Due to Inability to Obtain Flow from Fire Hydrant.Caused by Clogged Inlet Strainer (← links)
- 05000269/LER-1982-005-03, /03L-0:on 820302,reactor Bldg Spray Pump Declared Inoperable Due to Inability to Achieve Required Flow Rate. Caused by Running for 3-h W/No Suction Flow.Pump Replaced, Tested & Returned to Svc (← links)
- 05000270/LER-1982-007-01, /01T-0:on 820428,during Final Reactor Bldg Insp, One Vertical Tendon in Secondary Shield Wall Was Found Broken.Caused by Stress Corrosion of post-tensioning Wires Near Stressing Washers Due to Water (← links)
- 05000270/LER-1982-007, Forwards LER 82-007/01T-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1982-010-03, /03L-0:on 820407,reactor Bldg Isolation Valve 1LWD-1 Failed to Close After Pumping Reactor Bldg Normal Sump.Apparently Caused by Dirty Contact in Valve Operating Motor Starting Compartment.Contact Cleaned (← links)
- 05000269/LER-1982-010, Forwards LER 82-010/03L-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-005-01, /01T-0:on 820312,insp of Fuel Assembly W/Experimental Zircaloy Spacer Grids Revealed That Grids Had Moved from Normal Position.Caused by Loss of Contact W/Mark B4 Grids Due to Weak Springs & Too Much Gap Growth (← links)
- 05000270/LER-1982-005, Forwards LER 82-005/01T-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1982-005-01, /01T-0:on 820330,spent Fuel Pool Fans Found to Have Been Inoperable During 820323-29 Move of 10 Fuel Assemblies.Caused by Personnel Error in That White Tags for Fans Not Placed or Removed During Leak Rate Test Procedure (← links)
- 05000270/LER-1982-006-01, /01T-0:on 820402,spent Fuel Assembly Moved from Spent Fuel Pool Racks to Sipping Can While Spent Fuel Pit Ventilation Sys Out of Svc.Caused by Personnel Error.Fuel Handling Suspended (← links)
- 05000287/LER-1982-005, Forwards LER 82-005/01T-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-006, Forwards LER 82-006/01T-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1982-004-01, /01T:on 820302,testing of HPI Nozzle Areas Revealed Loose 2A2 Thermal Sleeves & Cracks in Id of Safe End & Piping.Caused by Thermal Fatigue.Cracked Piping,Safe End & Thermal Sleeves Replaced (← links)