- ML20052F987 (redirect page) (← links)
- 05000263/LER-1982-006, Forwards LER 82-006/03L-0 (← links)
- 05000263/LER-1982-004, Updated LER 82-004/01T-1:on 820410,inboard & Outboard 18-inch Dyrwell Vent Valves Failed to Close Upon Hand Switch Activation.Probably Caused by Solenoids Being Mounted Horizontally & Residual Core Magnetism.Solenoids Replaced (← links)
- 05000263/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000263/LER-1982-007, Forwards LER 82-007/03L-0 (← links)
- 05000263/LER-1982-016, Forwards LER 82-016/01T-0 (← links)
- 05000263/LER-1982-017-03, Outboard Ms Drain Isolation Valve MO-2374 Exceeded Tech Spec Table 3.7.1 Required Closure Time.Caused by Dc Motor Malfunction.Motor Replaced (← links)
- 05000263/LER-1982-016-01, /01T-0:on 820928,three Indications in 22-inch Diameter Reactor Recirculation Sys Riser Manifold End Cap Confirmed as Rejectable.Caused by Intergranular Stress Corrosion Cracking.End Cap to Be Replaced (← links)
- 05000263/LER-1982-014-01, /01T-0:on 821012,drywell Atmospheric Control Sys 2-inch,600-lb Inboard Isolation Bypass Valve CV-2385 Found Leaking in Excess of Tech Specs.Caused by Worn Groove in Disk Face.Disk Machined,Lapped & Reinstalled (← links)
- 05000263/LER-1982-012-01, /01T-0:on 820909,18 & 20-inch,150-lb T-seated Primary Containment Purge & Vent Valves Found Leaking in Excess of Tech Specs.Caused by Valves Improperly Closing & Seating Probably Due to T-ring Interference (← links)
- 05000263/LER-1982-011-01, /01T-0:on 820903,3-inch Outboard Main Steam Drain Isolation Valve MO-2374 Found Leaking in Excess of Tech Specs.Caused by Steam Eroding Valve Disc Due to Misalignment of Disc to Seat Ring.Seats Ground (← links)
- 05000263/LER-1982-010-01, /01T-0:on 820902,8-inch,150-lb RCIC Turbine Exhaust Check Valve 9 Found Leaking in Excess of Tech Specs. Caused by Leaking Valve Seat Due to Poor Svc Conditions. Disk & Seat Ring Replaced (← links)
- 05000263/LER-1982-008-03, /03L-0:on 820830,RCIC Barometer Condenser Cooling Water Supply Valve Failed.Caused by Severed Stem Due to Rotork Motor Operator Torque Switch Misadjustment.Valve Stem Replaced (← links)
- 05000263/LER-1982-007-03, /03L-0:on 820726,while Attempting to Add Oil to Governor During Monthly Diesel Generator Test,Personnel Changed Adjustment of Governor Shutdown Solenoid.Caused by Personnel Error.New Governor Installed.Procedure Revised (← links)
- 05000263/LER-1982-006-03, /03L-0:on 820504,during Normal Operation,Leak Discovered in 11 RHR Hx.Caused by HX Gasket Leak.Head Cover Flange Seal Welded to Floating Tube Sheet.Hx Control Valves Repaired.Manufacturer Proposed New Cover Design (← links)
- 05000263/LER-1982-005-03, /03L-0:on 820408,lead Lifted in Control Circuitry for Outboard Shutdown Cooling valve,MO-2030,rendering Valve Inoperable.Caused by Misinterpretation of Special Operating Procedure.Lead Reinstalled & Procedures Revised (← links)
- 05000263/LER-1982-005 (redirect page) (← links)
- 05000263/LER-1982-004-01, /01T-0:on 820410,ASCO Inboard & Outboard Drywell Vent 3-way Solenoid Valves,Model 830064C64U,failed to Close Upon Hand Switch Activation When Coil de-energized.Probably Caused by Horizontally Mounted Solenoids.Valves Replace (← links)
- ML20042F195 (← links)
- 05000263/LER-1982-003-03, /03L-0:on 820212,reactor Water Cleanup Primary Containment Inboard Isolation Valve MO-2397 Became Inoperable While in Full Open Position.Caused by Normally Energized Relay Coil 16A-K36 Shorting.Relay Replaced (← links)
- 05000263/LER-1982-003, Forwards LER 82-003/03L-0 (← links)
- 05000263/LER-1982-002-03, /03L-0:on 820107,core Spray Pump 11 Start Time Delay Relay Failed to Operate.Caused by Loose Terminal Connection & Microswitch Contact Burned Open.New GE CR 2820 Relay Installed (← links)
- 05000263/LER-1982-002, Forwards LER 82-002/03L-0 (← links)
- 05000263/LER-1982-001-01, /01T-0:on 820102,outboard Shutdown Cooling Suction Isolation Valve Found to Exceed Tech Spec Limits for Local Leak Rate Test.Caused by Valve Disc,Undersized by Extensive Lapping of Disc & Valve Body Seats,Traveling Too Far (← links)
- 05000263/LER-1982-001, Forwards LER 82-001/01T-0 (← links)