Finding | |
---|---|
Title | Failure to Ensure Required Design Basis Analysis was Maintained |
Description | The inspectors identified a finding of very low safety significance and associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure to verify that required analysis was in-place prior to superseding CA-00-082. Specifically, the licensee failed to recognize that the superseded calculation contained required analysis that was not verified in other current calculations. The licensee entered this issue into their Corrective Action Program where the licensee performed a preliminary analysis that verified the HPCI HELB was still bounded by the main steam line break analysis and to ensure that the analysis will be restored consistent with the provisions of CA-00-082 and License Amendment 117. The performance deficiency was determined to be more than minor because the finding was associated with the Mitigating Systems cornerstone attribute of design control and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding was a design deficiency that did not result in a loss of operability or functionality. This finding has a cross-cutting aspect in the area of Human Performance, Work Practices because the licensee did not use human error prevention techniques, such as self and peer checking, to ensure that work activities were performed safely. Specifically, the licensee failed to recognize that the superseded calculation contained required analysis that was not verified to be in other current calculations. |
Site: | Monticello |
---|---|
Report | IR 05000263/2013007 Section 1R17 |
Date counted | Dec 31, 2013 (2013Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.17 |
Inspectors (proximate) | A Dunlop G Hausman I Hafeez R Daley |
Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
CCA | H.12, Avoid Complacency |
INPO aspect | QA.4 |
' | |