ML24031A663

From kanterella
Revision as of 19:25, 5 October 2024 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
International, HI-STORM Umax FSAR Proposed FSAR Revision 3.1A
ML24031A663
Person / Time
Site: HI-STORM 100
Issue date: 01/31/2024
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML24031A659 List:
References
5021074
Download: ML24031A663 (1)


Text

Table 5.4.6

DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent 22 mremr/hr to the Inlet Vent

Table 5.4.7

DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid 66 mremr/hr (On the side of the closure lid approximately midheight)

Version B Lid 22 mremr/hr (On the side of the closure lid approximately midheight and adjacent to the inlet vent)

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 3.1A 5-45