Text

Table 5.4.6

DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent 22 mremr/hr to the Inlet Vent

Table 5.4.7

DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid 66 mremr/hr (On the side of the closure lid approximately midheight)

Version B Lid 22 mremr/hr (On the side of the closure lid approximately midheight and adjacent to the inlet vent)

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 3.1A 5-45