MONTHYEARML24180A1682024-06-30030 June 2024 International, Final Safety Analysis Report on the HI-STORM Umax Canister Storage System ML24031A6642024-01-31031 January 2024 International, HI-STORM Umax FSAR Proposed FSAR Revision 4.1A ML24031A6632024-01-31031 January 2024 International, HI-STORM Umax FSAR Proposed FSAR Revision 3.1A ML24031A6622024-01-31031 January 2024 International, HI-STORM Umax FSAR Proposed FSAR Revision 2.1A ML23348A3062023-12-14014 December 2023 Attachment 4 - Proposed HI-STORM Umax FSAR Revision 8 - Changed Pages ML21113A1932021-04-23023 April 2021 International, Final Safety Analysis Report Update for the HI-STORM Umax Canister Storage System ML20182A7292020-06-30030 June 2020 International, HI-2115090 HI-STORM Umax Final Safety Analysis Report, Rev 6 2024-06-30
[Table view] Category:Graphics incl Charts and Tables
MONTHYEARML24031A6642024-01-31031 January 2024 International, HI-STORM Umax FSAR Proposed FSAR Revision 4.1A ML24031A6632024-01-31031 January 2024 International, HI-STORM Umax FSAR Proposed FSAR Revision 3.1A ML24031A6622024-01-31031 January 2024 International, HI-STORM Umax FSAR Proposed FSAR Revision 2.1A ML20161A0882020-07-21021 July 2020 User Need Memo Umax A4 2024-01-31
[Table view] |
Text
Table 5.4.6
DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent 22 mremr/hr to the Inlet Vent
Table 5.4.7
DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid 66 mremr/hr (On the side of the closure lid approximately midheight)
Version B Lid 22 mremr/hr (On the side of the closure lid approximately midheight and adjacent to the inlet vent)
HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 3.1A 5-45