ML20249B559
ML20249B559 | |
Person / Time | |
---|---|
Site: | Dresden, Quad Cities, Zion |
Issue date: | 09/15/1976 |
From: | Roy G, Thompson D, Warnick R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) |
To: | |
References | |
PNO-76-096A, PNO-76-96A, NUDOCS 9806230302 | |
Download: ML20249B559 (2) | |
Category:PRELIMINARY NOTIFICATION OF EVENT OR OCCURRENCE (PNO
MONTHYEARPNO-III-98-030, on 980517,armed Security Guard on Patrol in Owner Controlled Area Reported to Security Person Lying Near Road.Guard Subsequently Reported Being Shot.No Intruder Found.Guard Admitted Shooting Himself in Foot1998-05-18018 May 1998
[Table view]PNO-III-98-030:on 980517,armed Security Guard on Patrol in Owner Controlled Area Reported to Security Person Lying Near Road.Guard Subsequently Reported Being Shot.No Intruder Found.Guard Admitted Shooting Himself in Foot PNO-III-98-006, on 980115,licensee Announced Permanent Shut Down of Station.Util Plans to Maintain Plant in Safstor Decommissioning Mode Until Approx 20141998-01-15015 January 1998 PNO-III-98-006:on 980115,licensee Announced Permanent Shut Down of Station.Util Plans to Maintain Plant in Safstor Decommissioning Mode Until Approx 2014 PNO-III-97-099, on 971219,unit Shut Down Due to Incomplete App R Safe Shutdown Analysis for Various Fire Scenarios. Licensee Completed Procedure Revs & Exited Administrative Technical Requirement in Early Dec1997-12-22022 December 1997 PNO-III-97-099:on 971219,unit Shut Down Due to Incomplete App R Safe Shutdown Analysis for Various Fire Scenarios. Licensee Completed Procedure Revs & Exited Administrative Technical Requirement in Early Dec PNO-III-97-071, on 970903,Comm Ed Announced Series of Mgt Changes & Restructuring of Nuclear Div Organization.New Site Vice Presidents at Braidwood & Quad Cities Former Plant Managers.State of Il Will Be Notified of Mgt Changes1997-09-0303 September 1997 PNO-III-97-071:on 970903,Comm Ed Announced Series of Mgt Changes & Restructuring of Nuclear Div Organization.New Site Vice Presidents at Braidwood & Quad Cities Former Plant Managers.State of Il Will Be Notified of Mgt Changes PNO-III-97-034, on 970417,decision Not to Replace SGs Made. as Result of Decision,Comm Ed Stated Zion Station Would Be Shut Down Before Expiration of Operating Licenses in 2013. Util Most Probably Support Operation to 20051997-04-18018 April 1997 PNO-III-97-034:on 970417,decision Not to Replace SGs Made. as Result of Decision,Comm Ed Stated Zion Station Would Be Shut Down Before Expiration of Operating Licenses in 2013. Util Most Probably Support Operation to 2005 PNO-III-97-035, on 970417,licensee Informed Zion Station of Results of Operations Assessment of Licensed & non-licensed Operating Staff.Licensee Assessed 187 Employees,Both in Mgt & Bargaining Unit Positions.States of Il & Wi Informed1997-04-18018 April 1997 PNO-III-97-035:on 970417,licensee Informed Zion Station of Results of Operations Assessment of Licensed & non-licensed Operating Staff.Licensee Assessed 187 Employees,Both in Mgt & Bargaining Unit Positions.States of Il & Wi Informed PNO-III-97-031, on 970401,licensee Identified Fractures on Auxiliary Switch Contact Block Mounted on 4 Kv Breaker Prior to Installation in Unit 2 safety-related Bus.Licensee Presently Testing Similar Breakers1997-04-10010 April 1997 PNO-III-97-031:on 970401,licensee Identified Fractures on Auxiliary Switch Contact Block Mounted on 4 Kv Breaker Prior to Installation in Unit 2 safety-related Bus.Licensee Presently Testing Similar Breakers PNO-III-97-024, on 970311,Unit 1 Sys Auxiliary Transformer Tripped as Result of Actuation of Sudden Pressure Relay, Indicating Possible Fault in Transformer.Nrc Providing round-the-clock Insp Coverage at Zion1997-03-14014 March 1997 PNO-III-97-024:on 970311,Unit 1 Sys Auxiliary Transformer Tripped as Result of Actuation of Sudden Pressure Relay, Indicating Possible Fault in Transformer.Nrc Providing round-the-clock Insp Coverage at Zion PNO-III-97-022, on 970311,Unit 1 Reactor Shut Down to Repair Reactor Protection Sys Scram Relay Malfunction.Conservative Decision Made to Repair Relay While Shutdown Rather than Troubleshoot During Power Operations1997-03-12012 March 1997 PNO-III-97-022:on 970311,Unit 1 Reactor Shut Down to Repair Reactor Protection Sys Scram Relay Malfunction.Conservative Decision Made to Repair Relay While Shutdown Rather than Troubleshoot During Power Operations PNO-III-97-010B, on 970221,plant Containment Spray Pump Found to Be Inoperable During Routine Testing.On 970307,AIT Held Exit Meeting W/Licensee.Ait Concluded That Significant Deficiencies in Oversight of Control Room Found1997-03-0707 March 1997 PNO-III-97-010B:on 970221,plant Containment Spray Pump Found to Be Inoperable During Routine Testing.On 970307,AIT Held Exit Meeting W/Licensee.Ait Concluded That Significant Deficiencies in Oversight of Control Room Found PNO-III-97-014, on 970227,employee Exiting Plant Had Set Off Radiation Detector.Employee Hands Found to Have Low Levels of Contamination.Staff from Dresden Plant Interviewed Employee Re Work Activities to Determine Contamination1997-02-28028 February 1997 PNO-III-97-014:on 970227,employee Exiting Plant Had Set Off Radiation Detector.Employee Hands Found to Have Low Levels of Contamination.Staff from Dresden Plant Interviewed Employee Re Work Activities to Determine Contamination PNO-III-97-010A, on 970221,AIT Dispatched to Zion Station to Review Improper Control Rod Movement Occurred,During Reactor Shutdown.Licensee Also Formed Event Investigation Team Led by J Brons,Comm Ed Vice-President Nuclear Support1997-02-26026 February 1997 PNO-III-97-010A:on 970221,AIT Dispatched to Zion Station to Review Improper Control Rod Movement Occurred,During Reactor Shutdown.Licensee Also Formed Event Investigation Team Led by J Brons,Comm Ed Vice-President Nuclear Support PNO-III-97-010, on 970219,diesel-driven CS Pump Found to Be Inoperable During Routine Surveillance Test.Reactor Operator Realized,Rods Were Moved Further than Expected.Actual Safety Significance of Error Minimal1997-02-24024 February 1997 PNO-III-97-010:on 970219,diesel-driven CS Pump Found to Be Inoperable During Routine Surveillance Test.Reactor Operator Realized,Rods Were Moved Further than Expected.Actual Safety Significance of Error Minimal PNO-III-97-009, on 970221,contaminated Scrap Metal Occurred. Licensee Also Indicated Addl Scrap Metal Located at Il Railroad Supply Co in Cordova,Il.Nrc Inspectors Monitored Licensee Activities Surrounding Incident1997-02-24024 February 1997 PNO-III-97-009:on 970221,contaminated Scrap Metal Occurred. Licensee Also Indicated Addl Scrap Metal Located at Il Railroad Supply Co in Cordova,Il.Nrc Inspectors Monitored Licensee Activities Surrounding Incident PNO-III-97-003, on 970117,outage Extended to Address Technical & Plant Condition Issues.Actions to Be Completed During Outage Extension Include Submitted Info1997-01-17017 January 1997 PNO-III-97-003:on 970117,outage Extended to Address Technical & Plant Condition Issues.Actions to Be Completed During Outage Extension Include Submitted Info PNO-III-96-066, on 961026,3B Reactor Recirculation Pump motor-generator Tripped.Licensee Determined Recovery of Idle Loop Impossible W/O Plant Shutdown & Began Controlled Shutdown.Independent Insp Safety Team Onsite for Review1996-10-28028 October 1996 PNO-III-96-066:on 961026,3B Reactor Recirculation Pump motor-generator Tripped.Licensee Determined Recovery of Idle Loop Impossible W/O Plant Shutdown & Began Controlled Shutdown.Independent Insp Safety Team Onsite for Review PNO-III-94-079, on 941002,shut Down of Units Occurred When Operators Discovered Temp Differential Between Loop a & Loop B Exceeded 50 Degrees F.Inspectors Monitored Licensees Activities During & After Shutdown1994-10-0303 October 1994 PNO-III-94-079:on 941002,shut Down of Units Occurred When Operators Discovered Temp Differential Between Loop a & Loop B Exceeded 50 Degrees F.Inspectors Monitored Licensees Activities During & After Shutdown PNO-III-93-051, on 930901,licensee Shut Unit 2 Down to Repair body-to-bonnet Leak in Feedwater Check Valve Which Makes Up Part of Containment Isolation Boundary.Leak Was Reduced to Weep by Tightening Bonnet Studs1993-09-0202 September 1993 PNO-III-93-051:on 930901,licensee Shut Unit 2 Down to Repair body-to-bonnet Leak in Feedwater Check Valve Which Makes Up Part of Containment Isolation Boundary.Leak Was Reduced to Weep by Tightening Bonnet Studs PNO-III-92-062A, provides Update on 920918 Incident in Which Rod Movement Error Occurred But Not Documented or Reported to Util Mgt.Util Terminated Employment of Four of Five Individuals Involved in Incident1992-12-0303 December 1992 PNO-III-92-062A:provides Update on 920918 Incident in Which Rod Movement Error Occurred But Not Documented or Reported to Util Mgt.Util Terminated Employment of Four of Five Individuals Involved in Incident PNO-III-92-048, on 920917,licensee Shut Down Unit 1 Because 1A turbine-driven AF Pump Declared Inoperable & Operability of One of Two 1A SG Injection Lines Considered Questionable. Equipment Debris Found in AF System.Repairs Require 1 Week1992-09-18018 September 1992 PNO-III-92-048:on 920917,licensee Shut Down Unit 1 Because 1A turbine-driven AF Pump Declared Inoperable & Operability of One of Two 1A SG Injection Lines Considered Questionable. Equipment Debris Found in AF System.Repairs Require 1 Week PNO-III-92-039A, on 920701,annunciators on Four CR Panels Were Lost About Three Times in Five Seconds.Later During Troubleshooting Efforts,Annunciators Were Again Lost.Cause Was Loose Connection in Copper Link within Fuse Holder1992-07-0202 July 1992 PNO-III-92-039A:on 920701,annunciators on Four CR Panels Were Lost About Three Times in Five Seconds.Later During Troubleshooting Efforts,Annunciators Were Again Lost.Cause Was Loose Connection in Copper Link within Fuse Holder PNO-III-91-038, w/Dresden Unit 3 in Cold Shutdown & Reactor Defueled,Licensee Experienced Loss of All Unit 3 Annunciators in Control Room.Loss Caused by Blown 3 Amp Fuse.Fuse Replaced & Control Room Annunciators Restored1991-09-23023 September 1991 PNO-III-91-038:w/Dresden Unit 3 in Cold Shutdown & Reactor Defueled,Licensee Experienced Loss of All Unit 3 Annunciators in Control Room.Loss Caused by Blown 3 Amp Fuse.Fuse Replaced & Control Room Annunciators Restored PNO-III-90-073, on 901029,reactor Scrammed from About 1% Power as Result of High Reactivity Caused by Improper Withdrawal of Control Rods1990-10-29029 October 1990 PNO-III-90-073:on 901029,reactor Scrammed from About 1% Power as Result of High Reactivity Caused by Improper Withdrawal of Control Rods PNO-III-90-061, on 900922,one of Two Main Transformers Exploded,Causing Reactor Trip from 40% Power After Turbine Trip Occurred.Cause Under Investigation.Replacement Transformer Will Be Installed in 3 Wks1990-09-24024 September 1990 PNO-III-90-061:on 900922,one of Two Main Transformers Exploded,Causing Reactor Trip from 40% Power After Turbine Trip Occurred.Cause Under Investigation.Replacement Transformer Will Be Installed in 3 Wks PNO-III-90-054, on 900802,safety Relief Valve Opened Unexpectedly & Remained Open.Licensee Evaluating Event,Which Exceeded Tech Spec Limit for Reactor Cooldown Rate.Valve Will Be Replaced & Failed Valve Will Be Inspected1990-08-0202 August 1990 PNO-III-90-054:on 900802,safety Relief Valve Opened Unexpectedly & Remained Open.Licensee Evaluating Event,Which Exceeded Tech Spec Limit for Reactor Cooldown Rate.Valve Will Be Replaced & Failed Valve Will Be Inspected PNO-III-90-053, on 900724,55-year Old Employee of fire-watch Contractor Died of Apparent Heart Attack,While on Duty in Turbine Building1990-07-24024 July 1990 PNO-III-90-053:on 900724,55-year Old Employee of fire-watch Contractor Died of Apparent Heart Attack,While on Duty in Turbine Building PNO-III-90-028, on 900410,dye Penetrant Testing on Inside of Reactor Vessel Head Identified 23 Cracks of Various Dimensions.Licensee Begun Repairing Cracks by Grinding Cracked Areas1990-04-11011 April 1990 PNO-III-90-028 on 900410,dye Penetrant Testing on Inside of Reactor Vessel Head Identified 23 Cracks of Various Dimensions.Licensee Begun Repairing Cracks by Grinding Cracked Areas ML20212A2591990-03-0606 March 1990 PNO-III-90-14A:on 900306,high Bearing Temperature Resulted in Common EDG for Two Units to Be Declared Inoperable on 900305 PNO-III-89-055, on 890817,security Guard Arrested for Robbery.Guard Site Access Badge Terminated on 890817 After Plant Police Notified Licensee of Planned Interview of Suspect Re Robberies1989-08-18018 August 1989 PNO-III-89-055:on 890817,security Guard Arrested for Robbery.Guard Site Access Badge Terminated on 890817 After Plant Police Notified Licensee of Planned Interview of Suspect Re Robberies PNO-III-89-042, on 890629,unit 1 Turbine Tripped,Causing Reactor Scam.Licensee in Process of Placing Reactor in Cold Shutdown to Repair Degraded Inner Seal on 1B Reactor Circulation Pump Prior to Startup.State of Il Notified1989-06-30030 June 1989 PNO-III-89-042:on 890629,unit 1 Turbine Tripped,Causing Reactor Scam.Licensee in Process of Placing Reactor in Cold Shutdown to Repair Degraded Inner Seal on 1B Reactor Circulation Pump Prior to Startup.State of Il Notified PNO-III-89-040, on 890624,power Lost to All Control Room Annunciators for Reactor & safety-related Sys.Caused by Troubleshooting Ground on Electrical Bus for balance-of-plant Annunciators & Blow Fuses1989-06-26026 June 1989 PNO-III-89-040:on 890624,power Lost to All Control Room Annunciators for Reactor & safety-related Sys.Caused by Troubleshooting Ground on Electrical Bus for balance-of-plant Annunciators & Blow Fuses PNO-III-89-036, on 890516,unit 1 Was Shutdown to Repair Socket Weld Leak on Feedwater Regulating Valve Bypass Line. Licensee Plans to Repair Other Minor Leaks & Perform Maint Activities During Unplanned Outage.State of Il Notified1989-05-19019 May 1989 PNO-III-89-036:on 890516,unit 1 Was Shutdown to Repair Socket Weld Leak on Feedwater Regulating Valve Bypass Line. Licensee Plans to Repair Other Minor Leaks & Perform Maint Activities During Unplanned Outage.State of Il Notified PNO-III-89-033A, on 890508 & 09,gaseous Release Occurred from Coolant Vol Control Sys Mixed Bed Demineralizer 1A Through Floor Drains to Auxiliary Bldg Vent Stack.Region III Monitoring Licensee Investigation1989-05-11011 May 1989 PNO-III-89-033A:on 890508 & 09,gaseous Release Occurred from Coolant Vol Control Sys Mixed Bed Demineralizer 1A Through Floor Drains to Auxiliary Bldg Vent Stack.Region III Monitoring Licensee Investigation PNO-III-89-027, on 890417,one of Four Electromagnetic Relief Valves Stuck Open During Testing & Reactor Manually Scrammed.Probably Caused by Eroded Seat on Pilot Valve. Relief & Pilot Valves Replaced1989-04-18018 April 1989 PNO-III-89-027:on 890417,one of Four Electromagnetic Relief Valves Stuck Open During Testing & Reactor Manually Scrammed.Probably Caused by Eroded Seat on Pilot Valve. Relief & Pilot Valves Replaced PNO-III-89-033, on 890308,high Radiation Alarm Received When Vent & Drain Valves of Coolant Vol Control Sys 1A Mixed Bed Demineralizer Opened.Caused by Use of Erroneous Stack Flow Rate.New Calculations Determined Release Rate within Limits1989-03-0808 March 1989 PNO-III-89-033:on 890308,high Radiation Alarm Received When Vent & Drain Valves of Coolant Vol Control Sys 1A Mixed Bed Demineralizer Opened.Caused by Use of Erroneous Stack Flow Rate.New Calculations Determined Release Rate within Limits PNO-III-89-017, on 890302,licensee Personnel Entered Unit 2 Drywell to Investigate Possible Leak.Steam Leak Observed from Vacuum Breaker on Discharge Piping from C Electromagnetic Rv,Which Was Indicative of Valve Leakage1989-03-0303 March 1989 PNO-III-89-017:on 890302,licensee Personnel Entered Unit 2 Drywell to Investigate Possible Leak.Steam Leak Observed from Vacuum Breaker on Discharge Piping from C Electromagnetic Rv,Which Was Indicative of Valve Leakage PNO-III-88-087, on 881025,licensee Determined That Neither of Two motor-driven Auxiliary Feedwater Pumps Would Automatically Start W/Loss of Offsite Power & lo-lo Steam Generator Level.Pumps Declared Inoperable1988-10-26026 October 1988 PNO-III-88-087:on 881025,licensee Determined That Neither of Two motor-driven Auxiliary Feedwater Pumps Would Automatically Start W/Loss of Offsite Power & lo-lo Steam Generator Level.Pumps Declared Inoperable PNO-III-88-066, on 880724,unit Shut Down to Investigate Ground (Short) in Main Generator.Plant Expected to Remain Shut Down for 2 to 6 Wks for Generator Repairs1988-07-25025 July 1988 PNO-III-88-066:on 880724,unit Shut Down to Investigate Ground (Short) in Main Generator.Plant Expected to Remain Shut Down for 2 to 6 Wks for Generator Repairs PNO-III-88-067, on 880722,controlled Shutdown Initiated to Repair Steam Leak.Unit Down for More than 48 H for Steam Leak Repair & Portions of Piping Which Exhibited Wall Thickness of Less than Three Inches.State of Il Notified1988-07-25025 July 1988 PNO-III-88-067:on 880722,controlled Shutdown Initiated to Repair Steam Leak.Unit Down for More than 48 H for Steam Leak Repair & Portions of Piping Which Exhibited Wall Thickness of Less than Three Inches.State of Il Notified PNO-III-88-053, on 880604,while Unit 3 Was Shutdown for Refueling Outage,Contractor Fire Watch Noticed Smoke Coming from Beneath Welder Working on Struts Being Installed on RWCU Sys Piping Penetration Inside RWCU Pipe Way Pit1988-06-0707 June 1988 PNO-III-88-053:on 880604,while Unit 3 Was Shutdown for Refueling Outage,Contractor Fire Watch Noticed Smoke Coming from Beneath Welder Working on Struts Being Installed on RWCU Sys Piping Penetration Inside RWCU Pipe Way Pit PNO-III-88-046, on 880517,test Performed as Part of Investigation of Dec 1987 Incident in Which Air Line Became Disconnected on One MSIV & Did Not Fully Close.Ait Will Maintain Insp Coverage of Activities Associated W/Msiv1988-05-20020 May 1988 PNO-III-88-046:on 880517,test Performed as Part of Investigation of Dec 1987 Incident in Which Air Line Became Disconnected on One MSIV & Did Not Fully Close.Ait Will Maintain Insp Coverage of Activities Associated W/Msiv PNO-II-87-135, on 871019,equipment Operator Attempted to Open Electrical Breaker for Circulating Water Pump 2A & Inadvertently Opened Adjacent Breaker for CRD Hydraulic Pump.Operator Actions Created Fire Ball,Damaging Breaker1987-10-21021 October 1987 PNO-II-87-135:on 871019,equipment Operator Attempted to Open Electrical Breaker for Circulating Water Pump 2A & Inadvertently Opened Adjacent Breaker for CRD Hydraulic Pump.Operator Actions Created Fire Ball,Damaging Breaker PNO-III-87-129, on 871002,facility Shut Down to Repair Packing Leaks on Both Pressurizer Spray Valves.Cause of Packing Leaks Not Stated.Valve Repairs Now Completed & Repair of Position Indicator on One Valve Underway1987-10-0505 October 1987 PNO-III-87-129:on 871002,facility Shut Down to Repair Packing Leaks on Both Pressurizer Spray Valves.Cause of Packing Leaks Not Stated.Valve Repairs Now Completed & Repair of Position Indicator on One Valve Underway PNO-III-87-127, on 870904,manipulation of Controls by non- Licensed Engineer Occurred.Caused by Personnel Error. Licensee Met W/Licensed Operators & Nuclear Engineers to Review Requirement Policy1987-10-0101 October 1987 PNO-III-87-127:on 870904,manipulation of Controls by non- Licensed Engineer Occurred.Caused by Personnel Error. Licensee Met W/Licensed Operators & Nuclear Engineers to Review Requirement Policy PNO-III-87-125, on 870918,both Units Shutdown Due Inability to Maintain Required Pressure Differential Between Secondary Containment & Atmosphere.Licensee Investigating Source of Leakage.State of Il Notified1987-09-21021 September 1987 PNO-III-87-125:on 870918,both Units Shutdown Due Inability to Maintain Required Pressure Differential Between Secondary Containment & Atmosphere.Licensee Investigating Source of Leakage.State of Il Notified PNO-III-87-105, on 870807,reactor Manually Scrammed.Caused by Variations in Feedwater Flow to Reactor & Leakage from Feedwater Sys.Ndt Performed Small Diameter Feedwater Piping & Other High Stress Areas1987-09-0404 September 1987 PNO-III-87-105:on 870807,reactor Manually Scrammed.Caused by Variations in Feedwater Flow to Reactor & Leakage from Feedwater Sys.Ndt Performed Small Diameter Feedwater Piping & Other High Stress Areas PNO-III-87-104, on 870801,reactor Scram Occurred as Result of Turbine & Generator Trips Due to Fault in Main Transformer. Licensee Investigating Cause of Problem.Unit Expected to Be Shut Down for Several Wks for Replacement of Transformer1987-08-0303 August 1987 PNO-III-87-104:on 870801,reactor Scram Occurred as Result of Turbine & Generator Trips Due to Fault in Main Transformer. Licensee Investigating Cause of Problem.Unit Expected to Be Shut Down for Several Wks for Replacement of Transformer PNO-III-87-096, on 870711,reactor Trip Occurred.Caused by Increased Feedwater Flow from 2.2 to 5.6 Million Gallons/H & Closure of All Msivs.Licensee Has No Plans to Operate in Element Control 3 on Feed Sys in the Near Future1987-07-13013 July 1987 PNO-III-87-096:on 870711,reactor Trip Occurred.Caused by Increased Feedwater Flow from 2.2 to 5.6 Million Gallons/H & Closure of All Msivs.Licensee Has No Plans to Operate in Element Control 3 on Feed Sys in the Near Future PNO-III-87-081, on 870610,earthquake Measuring 5.0 on Richter Scale Occurred Near Lawrenceville,Il.Unusual Events Declared by Six Power Stations But No Damage Observed.Ground Motion Felt at Five Other Plants1987-06-11011 June 1987 PNO-III-87-081:on 870610,earthquake Measuring 5.0 on Richter Scale Occurred Near Lawrenceville,Il.Unusual Events Declared by Six Power Stations But No Damage Observed.Ground Motion Felt at Five Other Plants PNO-III-87-073, on 870521,personnel Discovered Water Leaking Through Doors on Diesel Fuel Oil Storage Tank Rooms Into Turbine Bldg.Caused by Removal of Wrong Check Valve Bonnet. Water Pumped to Waste Water Treatment Sys for Processing1987-05-22022 May 1987 PNO-III-87-073:on 870521,personnel Discovered Water Leaking Through Doors on Diesel Fuel Oil Storage Tank Rooms Into Turbine Bldg.Caused by Removal of Wrong Check Valve Bonnet. Water Pumped to Waste Water Treatment Sys for Processing 1998-05-18 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000254/19990011999-10-0707 October 1999
[Table view]Insp Repts 50-254/99-01 & 50-265/99-01 on 990721-0908.No Violations Noted.Major Areas Inspected:Initiating Events, Mitigating Sys & Barrier Integrity IR 05000254/19990171999-09-15015 September 1999 Insp Repts 50-254/99-17 & 50-265/99-17 on 990823-27.No Violations Noted.Major Areas Inspected:Pilot Baseline Insp for Annual Review of Changes to Safety Analysis Rept & Biennial Review Permanent Plant Mod IR 05000254/19990161999-09-0909 September 1999 Errata to Insp Repts 50-254/99-16 & 50-265/99-16 Conducted on 990819.Administrative Error Was Corrected on Page 8 of Subj Rept.One Open Item Was Deleted & re-numbering of Two Other Items Were Identified IR 05000295/19990031999-09-0101 September 1999 Insp Repts 50-295/99-03 & 50-304/99-03 on 990608-0812.No Violations Noted.Major Areas Inspected:Licensee Facility & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000254/19990151999-08-25025 August 1999 Insp Repts 50-254/99-15 & 50-265/99-15 on 990816-20.No Violations Noted.Major Areas Inspected:Maint Rule Implementation IR 05000254/19990101999-08-20020 August 1999 Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each Site ML20211D2031999-08-19019 August 1999 Insp Repts 50-254/99-16 & 50-265/99-16 on 990719-22. Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Including Review of Access Authoization Program & Changes to Security Plan IR 05000254/19990121999-08-13013 August 1999 Insp Repts 50-254/99-12 & 50-265/99-12 on 990628-0716. Violations Noted.Major Areas Inspected:Corrective Action Process Which Included Methods Used for Identification, Cause Investigation & Correction of Quality Related Items IR 05000254/19990111999-08-13013 August 1999 Insp Repts 50-254/99-11 & 50-265/99-11 on 990601-0720.NCVs Noted.Major Areas Inspected:Performance in Initiating Events,Mitigating Sys,Barrier Integrity Cornerstones & Performance Indicator Verification IR 05000010/19990131999-08-0202 August 1999 Insp Rept 50-010/99-13 on 990702-27.No Violations Noted. Major Areas Inspected:Aspects of Facility Management & Control & Radiological Safety IR 05000254/19990141999-07-30030 July 1999 Insp Repts 50-254/99-14 & 50-265/99-14 on 990713-15.One Violation Noted & Treated as Ncv.Major Areas Inspected: Heat Sink Performance,Which Covers Inspectable Area Under Initiating Events & Mitigation Sys IR 05000254/19990131999-07-29029 July 1999 Insp Repts 50-254/99-13 & 50-265/99-13 on 990628-0702.No Violations Noted.Major Areas Inspected:Public Radiation Safety & Review of Gaseous & Liquid Radiological Effluents & of Radiological Environmental Monitoring Program ML20210C3781999-07-20020 July 1999 Notice of Violation from Insp on 990318.Violations Noted: on 980224,individual Attempted to Enter Protected Area of Plant with Firearm.Search Equipment Operator Failed to Failed to Secure Item & Prevent Access ML20210C4301999-07-20020 July 1999 Notice of Violation from Investigation on 990318.Violation Noted:On 980224,recipient Caused Util to Be in Violation of Section 2.C.6 of Licenses DPR-39 & DPR-48.Recipient Attempted to Enter Protected Area of Station with Handgun IR 05000254/19990091999-06-23023 June 1999 Insp Repts 50-254/99-09 & 50-265/99-09 on 990421-0531.One Violation of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000295/19990021999-06-18018 June 1999 Insp Repts 50-295/99-02 & 50-304/99-02 on 990121-0608.No Violations Noted.Major Areas Inspected:Licensee Facility Management & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000237/19990081999-06-18018 June 1999 Insp Repts 50-237/99-08 & 50-249/99-08 on 990408-0521. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19990061999-05-14014 May 1999 Insp Repts 50-254/99-06 & 50-265/99-06 on 990307-0420.Three Violations Noted & Being Treated as non-cited Violations. Major Areas Insptected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000010/19990091999-05-13013 May 1999 Insp Rept 50-010/99-09 on 990325-0506.Non-cited Violations Noted.Major Areas Inspected:Licensee Mgt & Control, Decommissioning Support Activities & Radiological Safety IR 05000254/19990081999-05-11011 May 1999 Insp Repts 50-254/99-08 & 50-265/99-08 on 990419-23.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation ML20205P2211999-04-0909 April 1999 Notice of Violation from Insp & Investigation Completed on 981112.Violation Noted:From Approx July,1997 to 980122,SGI Was Not Stored in Locked Storage Container While Unattended IR 05000254/19990031999-04-0909 April 1999 Insp Repts 50-254/99-03 & 50-265/99-03 on 990308-12.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000010/19990071999-04-0202 April 1999 Partially Withheld Security Insp Repts 50-010/99-07, 50-237/99-07 & 50-249/99-07 on 990308-12.Portions Withheld (Ref 10CFR2.790) ML20205J2951999-04-0101 April 1999 Insp Repts 50-254/99-01 & 50-265/99-01 on 990121-0306. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000254/19990071999-03-31031 March 1999 Radiation Protection Insp Repts 50-254/99-07 & 50-265/99-07 on 990309-12.No Violations Noted.Major Areas Inspected:Solid Radwaste Processing & Control Program & Radioactive Matls Shipping Program IR 05000254/19980211999-03-0505 March 1999 Insp Repts 50-254/98-21 & 50-265/98-21 on 981112-1218. Violation Noted:Major Areas Inspected:Isi Activities at Plant During Refueling Outage 15 ML20207G1771999-03-0505 March 1999 Notice of Violation from Insp on 99112-1218.Violation Noted:Licensee Had Not Included in Revised ISI Program,Basis for Determination That Code Required Exam Was Impractical For,Unit 2 Reactor Pressure Vessel Nozzle Weld Nsb IR 05000254/19990041999-02-26026 February 1999 Insp Repts 50-254/99-04 & 50-265/99-04 on 990201-05.No Violations Noted.Major Areas Inspected:Emergency Prepardeness Program as Aspect of Plant Support IR 05000254/19990021999-02-25025 February 1999 Insp Repts 50-254/99-02 & 50-265/99-02 on 990125-29.No Violations Noted.Major Areas Inspected:Radiation Protection & Chemistry Program Included Water Chemistry Control, Instrument Quality Control & internal-lab Comparison IR 05000010/19990021999-02-10010 February 1999 Insp Rept 50-010/99-02 on 981218-990129.No Violations Noted. Major Areas Inspected:Licensee Mgt & Control ML20199E9431999-01-14014 January 1999 Partially Withheld Security Insp Repts 50-254/98-24 & 50-265/98-24.Violations Noted.Major Areas Inspected:Plant Support Activities Re Physical Protection of Quad Cities Facility.Details Withheld (Ref 10CFR2.790) IR 05000254/19980221998-12-28028 December 1998 Insp Repts 50-254/98-22 & 50-265/98-22 on 981130-1204.No Violations Noted.Major Areas Inspected:Radiation Protection Staff Preparation for Q1R15 Refueling Outage,Including Review of ALARA Planning & Work Plan Integration IR 05000254/19980201998-12-28028 December 1998 Insp Repts 50-254/98-20 & 50-265/98-20 on 981014-1201.No Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000254/19980191998-12-18018 December 1998 Insp Repts 50-254/98-19 & 50-265/98-19 on 981019-1106. Violations Noted.Major Areas Inspected:Effectiveness of Engineering & Technical Support Provided to Plant in Performance of Routine & Reactive Site Activities ML20198G2901998-12-18018 December 1998 Notice of Violations from Insp on 981019-1106.Violations Noted:As of 980327,performance of Listed Test Procedures Did Not Demonstrate Equipment Could Perform Satisfactorily Under Design Conditions IR 05000010/19980181998-11-13013 November 1998 Partially Withheld Insp Repts 50-010/98-18,50-237/98-27 & 50-249/98-27 on 981013-16 (Ref 10CFR73.21).Violations Noted. Major Areas Inspected:Physical Protection of Plant Facility IR 05000254/19980171998-11-0505 November 1998 Insp Repts 50-254/98-17 & 50-265/98-17 on 980902-1014.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000295/19980101998-11-0303 November 1998 Insp Repts 50-295/98-10 & 50-304/98-10 on 980814-1008.No Violations Noted.Major Areas Inspected:Facility Mgt & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000254/19980181998-10-15015 October 1998 Partially Withheld Insp Repts 50-254/98-18 & 50-265/98-18 on 980914-18 (Ref 10CFR73.71).No Violations Identified.Major Areas Inspected:Review of Plant Support Activities,Security Activities Re Onsite Personnel Access & Communications IR 05000010/19980161998-10-0606 October 1998 Insp Rept 50-010/98-16 on 980723-0918.No Violations Noted. Major Areas Inspected:Aspects of Licensee Mgt & Control, Sf Safety & Radiological Safety.Followup Insp Performed on Previously Identified Issue IR 05000254/19980131998-09-22022 September 1998 Insp Repts 50-254/98-13 & 50-265/98-13 on 980716-0901.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000254/19980141998-09-17017 September 1998 Insp Repts 50-254/98-14 & 50-265/98-14 on 980825-28.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan ML20154G4301998-09-11011 September 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $88,000.Violation Noted:As of 970926,licensee Failed to Provide Alternate Shutdown Capability for Some Fire Areas of Facility Containing Safe Shutdown Equipment ML20195D1951998-09-0808 September 1998 EN-98-057B:on 980911,notice of Proposed Imposition of Civil Penalty in Amount of $88,000 Issued to Licensee.Action Based on One Severity Level II Problem Involving Very Significant Inadequacies in Comm Ed Capability to Shut Down IR 05000295/19980091998-09-0808 September 1998 Insp Repts 50-295/98-09 & 50-304/98-09 on 980626-0813.No Violations Noted.Major Areas Inspected:Facility Mgt & Control,Decommissioning Support Activities,Sf Safety & Radiological Safety IR 05000254/19980161998-09-0404 September 1998 Insp Repts 50-254/98-16 & 50-265/98-16 on 980810-14.No Violations Noted.Major Areas Inspected:Radiation Protection Program Included External & Internal Exposure Control,Whole Body Counting & Contamination & Survey Monitoring Program ML20237D6671998-08-11011 August 1998 Notice of Violation from Insp on 980529-0716.Violation Noted:On 980622,while Performing Quad Cities Operating Surveillance Procedure 6600-01,rev 24,operator Failed to Position Throttle Air Box Drain Valve One Turn ML20195D2341998-08-11011 August 1998 EN-98-057:on 980814,notice of Proposed Imposition of Civil Penalty in Amount of $143,000 Issued to Licensee.Action Based on One Severity Level II Problem & One Severity Level III Violation IR 05000254/19980121998-08-11011 August 1998 Insp Repts 50-254/98-12 & 50-265/98-12 on 980529-0716. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000254/19980151998-07-31031 July 1998 Insp Repts 50-254/98-15 & 50-265/98-15 on 980721-24.No Violations Noted.Major Areas Inspected:Aspects of Licensee Corrective Actions & Engineering Involvement in Corrective Actions Process 1999-09-09 |
Text
o' % - n , .
,. [,f.-)
Wily t ar.E :") -
< r.
PRELIMINARY NOTIFICATION R. 1'
'"\ lpH hl2, September 15, 1976 -
PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-76-96A This preliminary notification constitutes EARLY notice of an event of.
POSSIBLE safety or public interest significance. The information presented is as initially received without verification or evaluation and is basically all that is known by IE staff on this date.
l-Facility: Commonwealth Edison Company (Dresden, Quad-Cities and Zion)
Subject:
NRC REGIONAL DIRECTOR TESTIFIES AT HEARING BEFORE ILLINOIS COMHERCE COMMISSION Reference PNO-76-96, June 9, 1976.
The Director of the NRC's Region III (Chicago) Office tastified September 13, 1976, before an Illinois Commerce Commir,sion (ICC) Hearing in Chicago concerning the handling of radioactive effluents at Commonwealth Edison Company's operating nuclear power stations (Dresden, Quad-Cities and Zion). The subpoena issued the Regional Director on June 9,1976 by ICC, at the urging of Citizens for a Better Environment (Chicago based environmental group), was denied by OELD; however, in accordance with an agreement reached by the ICC hearing examiner and OELD, the Regional Director appeared at the hearing to assist the ICC in determining whether Commonwealth Edison had taken all " technically and economically feasible steps" to abate pollution in accordance with a previous ICC Order. An OELD attorney accompanied the Regional Director at the hearing.
- Written testimony was provided by the Regional Director in response to questions submitted by CBE. This testimony focused on many ,of the problems experienced in recent years at the Dresden, Quad-Cities and Zion Stations and was generally unfavorable to Commonwealth Edison Company. Inspection reports, licensee event reports, and other official correspondence were introduced as exhibits. In an attempt to provide perspective to this testimony, the Regional Director also prepared supplemental testimony com-paring effluent data for Commonwealth Edison's nuclear plants with other operating nuclear plants within Region III.
Attorneys for Commonwealth Edison Company objected to the NRC testimony on grounds of relevancy and jurisdiction; however, the objection was overruled. Cross-examination on the prepared testimony was conducted by Commonwealth Edison Company attorneys, the Illinois Attorney General's office, and the ICC staff.
\
CONTINUE ,
9806230302 760915 PDR I&E PNO-79-96A PDR s .
~
[- .- o l
Page 2 PNO-76-96A Continued September 15, 1976 Several news media representatives and state officials covered the hearing.
Although one newspaper carried a somewhat distorted story, news coverage has been generally low-key and straight-forward.
This PN is prepared because of the uniqueness of the Hearing and sensitive y., nature of the testimony provided.
Contact:
RFWarnick, IE 27261 GWRoy, IE x27261 DThompson, IE x27541 Distribution: -
Chairman Rowden Commissioner Mason S. J. Chilk, SECY Commissioner Gilinsky C. C. Kammerer, CA G. F. Murphy, JCAE Commissioner Kennedy L. V. Gossick, EDO E. Volgenau, OIE J. A. Harris, PA B. C. Rusche, NRR H. K. Shapar, ELD T. J. McTiernan, AIA K. R. Chapman, NMSS R. G. Ryan, OSP Transmitted: PBldg ; H St ; MNBB ; Luge ;