Category:ENVIRONMENTAL MONITORING REPORTS(&RADIOLOGICAL)-PERIODIC
MONTHYEARML20205T0581998-12-31031 December 1998 Annual Radiological Environ Operating Rept 15 for 1998 ML20206E2161998-12-31031 December 1998 1998 Annual Environ Operating Rept (Non-Radiological) for Limerick Generating Station,Units 1 & 2 ML20216F3371997-12-31031 December 1997 Annual Environmental Operating Rept (Non-Radiological) for 970101-1231 ML20217M6471997-12-31031 December 1997 Annual Radiological Environ Operating Rept 14,Jan-Dec 1997 for Limerick Generating Station,Units 1 & 2 ML20203L5691997-12-31031 December 1997 Occupational Exposure Tabulation Rept for LGS Units 1 & 2 for 1997 ML20203H2201997-12-31031 December 1997 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class Rept 13 for 1997 ML20217P1941997-12-31031 December 1997 Annual Environ Operating Rept (Non-Radiological) for Jan-Dec 1997, for LGS Units 1 & 2 ML20203H1911997-12-31031 December 1997 Annual Effluent Release Rept 23 for Jan-Dec 1997 ML20138J5291996-12-31031 December 1996 Annual Environ Operating Rept (Non-Radiological) for Jan- Dec 1996 ML20135C7731996-12-31031 December 1996 1996 Annual Tower No 1 Joint Frequency Distribution of Wind Speed & Direction by Atmospheric Stability Class Rept No 12 ML20135C7691996-12-31031 December 1996 1996 Annual Effluent Release Rept No 22 ML20135D0161996-12-31031 December 1996 Occupational Exposure Tabulation Rept for LGS Units 1 & 2 for 1996 ML20148B6671996-12-31031 December 1996 LGS Units 1 & 2 Annual Radiological Environ Operating Rept 13 for 960101-1231 ML20108B7391995-12-31031 December 1995 Annual Radiological Environ Operating Rept 12 Jan-Dec 1995 ML20108C9281995-12-31031 December 1995 LGS Units 1 & 2 1995 Annual Environ Operating Rept (Non- Radiological) Jan-Dec 1995 ML20100L8861995-12-31031 December 1995 Annual Effluent Release Rept 21,Jan-Dec 1995 ML20100L8961995-12-31031 December 1995 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class 1995 Rept 11 ML20082N5061994-12-31031 December 1994 Annual Environ Operating Rept ML20080N1121994-12-31031 December 1994 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class 1994 Rept 10 ML20080N1061994-12-31031 December 1994 Annual Effluent Release Rept 20 Jan-Dec 1994 PECO Energy LGS Units 1 & 2 ML20087H7231994-12-31031 December 1994 Annual Radiological Environ Operating Rept 11 for Jan-Dec 1994 ML20067D3191993-12-31031 December 1993 Semiannual Effluent Release Rept 19 Jul-Dec 1993 for Limerick Generating Station Units 1 & 2 ML20067D3241993-12-31031 December 1993 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class 1993 Rept 9 ML20070M6971993-12-31031 December 1993 Annual Environ Operating Rept (Nonradiological) ML20029D2371993-12-31031 December 1993 Annual Radiological Environ Operating Rept 10 Jan-Dec 1993. W/940422 Ltr ML20056G1031993-06-30030 June 1993 Semiannual Effluent Release Rept 18 Jan-June 1993. W/ ML20012G4771992-12-31031 December 1992 PECO Occupation Exposure Tabulation Rept 7 for Limerick Generating Station, for Period Jan - Dec 1992.W/930228 Ltr ML20114C0451992-06-30030 June 1992 Semi-Annual Effluent Release Rept 16 for 920101 Through 920630 ML20095H8691991-12-31031 December 1991 Annual Radiological Environ Operating Rept for 1991,Rept 8 ML20095E7721991-12-31031 December 1991 Annual Environ Operating Rept (Nonradiological) ML20094H0341991-12-31031 December 1991 Std Format for Reporting Number of Personnel & Man-Rem by Work & Job Function for Period Jan-Dec 1991 ML20094G8931991-12-31031 December 1991 Annual Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class 1991 Rept 7 ML20094G8891991-12-31031 December 1991 Semiannual Effluent Release Rept 15,Jul-Dec 1991 ML20083D9061991-08-31031 August 1991 NPDES Discharge Monitoring Repts for Aug 1991 ML20082N0061991-06-30030 June 1991 Semiannual Effluent Release Rept,Jan-June 1991 ML20073H3351990-12-31031 December 1990 Annual Environ Monitoring Rept (Nonradiological) ML20073R1631990-12-31031 December 1990 Revised Recorded Annual Whole Body Exposures, 1990 ML20076N2961990-12-31031 December 1990 Annual Radiological Environ Operating Rept 7 ML20029B2871990-12-31031 December 1990 Occupational Exposure Tabulation Rept 7 for Limerick Generating Station,Units 1 & 2 for 1990. W/910228 Ltr ML20029C3241990-12-31031 December 1990 Rev 1 to Occupational Exposure Tabulation Rept 7 for Limerick Generating Station Units 1 & 2 for 1990, Correcting Period Dates on Recorded Annual Whole Body Exposure ML20059E6321990-06-30030 June 1990 Semiannual Effluent Release Rept for Jan-June 1990 ML20012B4031989-12-31031 December 1989 Std Format for Reporting of Personnel & M/Rem by Work & Job Function for Jan-Dec 1989. ML20073R1591989-12-31031 December 1989 Revised Recorded Annual Whole Body Exposures, 1989 ML20012A1191989-12-31031 December 1989 Semiannual Effluent Release Rept 11,Jul Through Dec 1989. ML20246K5531989-08-29029 August 1989 Semiannual Effluent Release Rept 10 Jan-Jun 1989 ML19327B8561989-06-30030 June 1989 Rev 1 to Semi-Annual Effluent Release Rept 10 for Jan-June 1989 ML20246D7361989-04-28028 April 1989 1988 Annual Radiological Environ Monitoring Rept 5. Small Amount of plant-related Zn-65 Activity Found in Fish ML20246D6681988-12-31031 December 1988 1988 Annual Environ Operating Rept (Non-Radiological) ML20236C7761988-12-31031 December 1988 Annual Occupational Exposure Tabulation 5 for Jan-Dec 1988 ML20073R1561988-12-31031 December 1988 Revised Recorded Annual Whole Body Exposures, 1988 1998-12-31
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML20206C9871999-04-27027 April 1999 NPDES Noncompliance Notification:On 990319,station Personnel Observed Foam Emanating from Manhole Vent Associated with Outfall 001,no Foam Was Observed on Any Waterway.Caused by Inappropriate Addition of Betz 3625 to Spray Pond ML20207D6171999-02-26026 February 1999 NPDES Noncompliance Notification:On 990111,discovered That Weelkly Analysis for non-oxidizing Biocide Betz 3625 Was Not Performed.Caused by Sample Being Inappropriately Delayed for Future Chemical Addition.Counseled Individuals Involved ML20202F0591999-01-19019 January 1999 NPDES Noncompliance Notification:On 990112,Auxiliary Boiler Source Number OAS502 Found to Have Malfunctioning Opacity Monitor.Caused by Stepdown Transformer within Power Supply. Power Supply Replaced ML20206E2161998-12-31031 December 1998 1998 Annual Environ Operating Rept (Non-Radiological) for Limerick Generating Station,Units 1 & 2 ML20205T0581998-12-31031 December 1998 Annual Radiological Environ Operating Rept 15 for 1998 ML20206R3491998-12-21021 December 1998 NPDES Noncompliance Notification:On 981102,500 Gallons of 12% Sodium Hypochlorite Released to Environ.Caused by Failure of Tank Discharge Fittings & Subsequent Leaks from Secondary Containment.Culvert Was Flushed Repeatedly ML20198J2811998-12-21021 December 1998 NPDES Noncompliance Notification:On 981102,release of 500 Gallons of 12% Sodium Hypochlorite to Environment Occurred. Caused by Failure of Tank Discharge Fittings.Integrity Testing Will Be Performed on All New Tanks.With ML20236V2001998-07-27027 July 1998 NPDES Noncompliance Notification:On 980619,geometric Mean Coliform Concentration Calculated to Be 223 Colonies Per 100 Ml.Sample Procedure Enhanced to Ensure Normal Operating Conditions ML20248C9461998-05-27027 May 1998 NPDES Noncompliance Notification:On 980414,total Iron Discharge Through Outfall 001 Exceeded Limits Set in Ltr Dtd 960508.Total Iron Discharge Limit Exceeded During Cleaning Evolution.Limit Revised ML20217N6921998-02-27027 February 1998 NPDES Noncompliance Notification:On 980107 Net Total Suspended Solids (TSS) for Units 1 & 2 Cooling Towers at Outfall 001 Exceeded NPDES Permit Daily Limit of 60 Ppm. Caused by Contaminated Sample Lines.Replaced Tygon Tubing ML20203H1911997-12-31031 December 1997 Annual Effluent Release Rept 23 for Jan-Dec 1997 ML20216F3371997-12-31031 December 1997 Annual Environmental Operating Rept (Non-Radiological) for 970101-1231 ML20203L5691997-12-31031 December 1997 Occupational Exposure Tabulation Rept for LGS Units 1 & 2 for 1997 ML20203H2201997-12-31031 December 1997 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class Rept 13 for 1997 ML20217P1941997-12-31031 December 1997 Annual Environ Operating Rept (Non-Radiological) for Jan-Dec 1997, for LGS Units 1 & 2 ML20217M6471997-12-31031 December 1997 Annual Radiological Environ Operating Rept 14,Jan-Dec 1997 for Limerick Generating Station,Units 1 & 2 ML20141G0271997-06-27027 June 1997 NPDES Noncompliance Notification:On 970512,sample for Kjeldahl Omitted Due to Personnel Error.Counseled Individual Responsible.On 970521,Net TSS Exceeded NPDES Daily Limit Due to Fouled Sample Tubing.Replaced Sample Tubing ML20137M5511997-03-27027 March 1997 NPDES Noncompliance Notification:On 970228,flow Integrator Used to Measure Spray Pond Effluent Flow Was Identified to Be Malfunctioning & Declared Inoperable Due to Lodged Debris.Revised Procedure for Spray Pond Effluent Flow ML20134G3241997-01-31031 January 1997 NPDES Noncompliance Notification:On 970108,util Informed NRC That PA Dept of Environ Protection Granted Approval for Temporary Discharge at Lgs,Per 961219 ML20135D0161996-12-31031 December 1996 Occupational Exposure Tabulation Rept for LGS Units 1 & 2 for 1996 ML20148B6671996-12-31031 December 1996 LGS Units 1 & 2 Annual Radiological Environ Operating Rept 13 for 960101-1231 ML20135C7691996-12-31031 December 1996 1996 Annual Effluent Release Rept No 22 ML20138J5291996-12-31031 December 1996 Annual Environ Operating Rept (Non-Radiological) for Jan- Dec 1996 ML20135C7731996-12-31031 December 1996 1996 Annual Tower No 1 Joint Frequency Distribution of Wind Speed & Direction by Atmospheric Stability Class Rept No 12 ML20138G9651996-12-24024 December 1996 NPDES Noncompliance Notification:On 960428,calibration of Flowmeter Used to Measure Spray Pond Flow Was Not Checked on Routine Basis Because Person Required to Develop Maint Was Unaware of Requirements.Installed New Meter ML20135A5851996-11-27027 November 1996 NPDES Noncompliance Notification:On July-Sept 1996 Re NPDES Limit for Fecal Coloform Concentration Not Met.Caused by Inadequate Gasket Installation.Ozonators Overhauled to Ensure Peak Performance ML20134E0641996-10-28028 October 1996 NPDES Noncompliance Notification:During Month of Sept 1996, NPDES Limit for Fecal Coliform Concentration at Discharge of Bradshaw Reservoir Pumps Was Not Met.Caused by Leaking Gaskets on Ozone Gas Diffusers.New Gaskets,Installed ML20129E5681996-09-27027 September 1996 NPDES Noncompliance Notification:On 960805,geometric Mean of Fecal Coliform Concentration Calculated to Be 641 Colonies Per 100 Ml.Cause Suspected to Be Due to Malfunctioning Ozone Disinfection Sys.Adjustments to Sys Have Been Made ML20129E5411996-09-26026 September 1996 NPDES Noncompliance Notification:On 960812,discharge Observed from Unit 2 Cooling Tower Overflow to Outfall 021. Caused by Personnel Error in Performing Required Analysis of Cooling Tower Overflow Sample.Individual Counseled ML20117G7071996-08-23023 August 1996 NPDES Noncompliance Notification:On 960715,geometric Mean of Fecal Coliform Concentration Exceeded NPDES Permit Limit. Caused by Leaking Seals on Ozone Diffusers.Temporary Adjustments Made to Ozone Gas Flow Balance ML20116B3851996-07-24024 July 1996 NPDES Noncompliance Notification:On 960602 Identified Ph Levels Exceeded NPDES Permit Limitations.Caused by Natural Biological activity.CO2 Injection Established,Maintained & Monitored Until 960612 ML20115G1151996-07-12012 July 1996 NPDES Noncompliance Notification:On 960619,resulting Net TSS Value 82.8 mg/1,exceeded Max Daily Limit of 60 Mg/L.Caused by Excessive Storm Water Runoff.Net TSS Revised ML20113C4451996-06-24024 June 1996 NPDES Noncompliance Notification:On 960318,flow Integrator Used to Measure Spray Pond Effluent Flow Declared Inoperable.Caused by Faulty Flow Integrator.Frequency of Use of Instrument Changed to Daily as Stated in Issue Number ML20108A3801996-04-28028 April 1996 NPDES Noncompliance Notification:On 960223,identified Seven Issues of Administrative non-compliance/ambiguity W/Permits. Caused by Inadequate Administration.Individuals Gained Better Understanding W/Guidance ML20108A3671996-04-28028 April 1996 NPDES Noncompliance Notification:On 960314,personnel Observed Sewage Overflowing from MH-07 & Into Storm Drain W-4.Caused by Blockage of Pipe Section Between MH-07 & MH-08.Sewer Contract Svc Pressure Cleaned ML20101K4661996-03-28028 March 1996 NPDES Noncompliance Notification:On 960218,discovered That No Records Existed for Bradshae Reservoir Discharge Water Temp for Listed Time Periods.Caused by Temporary Reassigment of Personnel.Review of Staffing in Progress ML20100P6311996-02-28028 February 1996 NPDES Noncompliance Notification:On 951108,discharge 001 Net TSS in Excess of Maximum Daily Limit.Caused by Flaw in Methodology to Calculate Net TSS concentration.Follow-up Composite Samples Taken ML20108C9281995-12-31031 December 1995 LGS Units 1 & 2 1995 Annual Environ Operating Rept (Non- Radiological) Jan-Dec 1995 ML20100L8861995-12-31031 December 1995 Annual Effluent Release Rept 21,Jan-Dec 1995 ML20108B7391995-12-31031 December 1995 Annual Radiological Environ Operating Rept 12 Jan-Dec 1995 ML20100L8961995-12-31031 December 1995 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class 1995 Rept 11 ML20080N1061994-12-31031 December 1994 Annual Effluent Release Rept 20 Jan-Dec 1994 PECO Energy LGS Units 1 & 2 ML20082N5061994-12-31031 December 1994 Annual Environ Operating Rept ML20087H7231994-12-31031 December 1994 Annual Radiological Environ Operating Rept 11 for Jan-Dec 1994 ML20080N1121994-12-31031 December 1994 Tower 1 Joint Frequency Distributions of Wind Speed & Direction by Atmospheric Stability Class 1994 Rept 10 ML20072R4601994-08-31031 August 1994 NPDES Noncompliance Notification:On 940708 & 0815,Discharge 001 Total Zinc Concentrations Exceeded Max Daily Limitations.Daily Zinc Trending Analysis Will Be Upgraded & Chemistry Technician Involved in 940815 Event Counselled ML20071L1761994-07-27027 July 1994 NPDES Noncompliance Notification:On 940609,zinc Analyses Indicated That Discharge 001 Total Zinc Levels in Excess of Max Daily Limitations in Both Cooling Towers.Daily Zinc Control Limits Will Be Administratively Maintained Lower ML20149E7291994-07-26026 July 1994 NPDES Discharge Monitoring Rept:On 940713,approx 18 Gallons of Betz Clamtrol CT-1 Inadvertently Released from Injection Sys Located South of LGS Spraypond Pumphouse.Caused by Break in Pump Discharge Line.Polyethylene Piping Replaced ML20065B9221994-03-25025 March 1994 NPDES Noncompliances Notification:On 940204,discharge 001 Maximum Daily Limit of 1.0 mg/1 Total Zinc Was Exceeded. Caused by Low Ph Transient in Unit 2 Cooling Tower Water Sys.Isolated Acid Injection Sys ML20064C7701994-02-25025 February 1994 NPDES Noncompliance Notification:On 940116 & 17 Manual Reactor Scram Occurred.Caused by Failure to Adequately Throttle Cooling Tower Bypass Valves.Procedure Revised 1999-04-27
[Table view] |
Text
_ _ _ _ _ _ _ _ _ _ _ _
6 PHILADELPHIA ELECTRIC COMPANY LIMERICK GENERATION STATION UNIT 1 DOCKET NO. 50-352 OCCUPATIONAL EXPO 3URE TABULATION NO. 4 JANUARY 1, 1987 THROUGH DECEMBER 31, 1987 Submitted to The United States Nuclear Regulatory Commission Pursuant to Facility Operating License No. NPF-39 Preparation Directed by:
G. M. Leitch, Manager Limerick Generating Station 8803020161 871231
~
$5,4 J PDR ADOCK 05000352
TABLE OF CONTENTS
. Page No.
I. INTRODUCTION 1 II. TABLES.
A. Standard Format for Reporting 2 Number of Personnel and Man-Rem for Work and Job Function B. Recorded Annual Wholebody 3 Exposure for Calendar Year 1987 i
L l
j 1
i l l l
i
l I. INTRODUCTION ANNUAL OCCUPATIONAL EXPOSURE TABULATION A tabulation of station, utility, and other personnel receiving exposure, and their associated man-rem exposure according to work and job function is presented for Limerick Generating Station Unit 1 as Table A in accordance with the Routine Reporting Requirements of Technical Specification 6.9.1.5 of Operating License NPF-39. In addition, a statistical summary report of the annual wholebody exposures for the year is presented as Table B in accordance with 10 CPR 20.407(b) and includes all measureable exposures. This data covers the period January 1, 1987 through December 31, 1987.
(1)
TABLE A PHILADELPHIA ELECTRIC COMPANY
- LIMERICX NUCLEA2 GENERATING STATION POTTSTOWN. PENNSYLVANIA 19464
- LICENSE NOS. NPF - 39 STANDARO FORMAT FOR REPORTING NUMBER OF PERSONNEL AND MAN-REM 8V WORK AND JOB FUNCTION FOR THE PEPIOD 01/01/87 THRU 12/31/87 NUMBER OF PERSONS WITH MEASURABLE EXPOSURE TOTAL MAN-REM WORK FUNCTION STATION UTILITY CONTRACTORS STATION UTILITV CONTRACTORS JOB FUNCTION EMPLOYEES EMPLOYEES AND OTHERS EMPLOYEES EMPLOYEES AND OTHERS REACTOR OPERATIONS AND SURVEILLANCE MAINTENANCE PERSONNEL 0 4 11 0.000 0.849 0.937 OPERATING PERSONNEL 14 0 9 1.241 0.000 0.912 HEALTH PH(SICS PERSONNEL 10 0 1 3.369 0.000 0.009 SUPERVISORY PERSONNEL 0 0 1 0.000 0.000 0.010 ENGINEERING PERSONNEL 0 0 0 0.000 0.000 0.000 ROUTINE MAINTENANCE MAINTENANCE PERSONNEL 8 361 787 0.615 24.069 63.543 OPE 4ATING PERSONNEL 89 58 373 7.053 3.b90 26.690 NEALTG *MYSICS PERSONNEL 50 9 74 8.380 0.644 8.890 SU PERVI SOR'. PERSONNEL 6 2 27 0.256 0.026 0.719 ENGINEERING PERIONNEL 48 60 145 3.012 5.262 .8.029 INSERVICE INSPECTIOf4 MAINTENANCE PERSONNEL 0 0 0 0.000 0.000 0.000 OPERATING PERSONNEL 0 0 0 0.000 0.000 0.000 HEALTH PHYSICS PERSONNEL 0 0 0 0.000 0.000 0.000 SUPERVISORY PERSONNEL 0 0 0 0.000 0.000 0.000.
ENGINEERING PERSONNEL 0 0 0 0.000 0.000 0.000 SPECIAL MAINTENANCE MAINTENANCE PERSONNEL 0 0 0 0.000 0.000 0.000 OPERATING PERSONNEL 0 0 0 0.000 0.000 0.000 HEALTH PHYSICS PERSONNEL 0 0 0 0.000 0.000 0.000 SUPERVISORY PERSONNEL 0 0 0 0.000 0.000 0.000 ENGINEERING PERSONNEL 0 0 0 0.000 0.000 0.000 MASTE PROCESSING MAINTENANCE PERSONNEL 0 3 14 0.000 0.481 0.770 OPERATING PERSONNEL 7 0 18 0.911 0.000 3.076 HEALTH PHYSICS PERSONNEL 1 0 1 0.388 0.000 0.016 SUPERVISORY PERSONNEL 0 0 0 0.000 0.000 0.000 ENGINEERING PERSONNEL 0 1 1 0.000 0.024 0.056 REFUELING MAINTENANCE PERSONNEL 0 0 0 0.000 0.000 0.000 OPERATING PERSONNEL 0 0 0 0.000 0.000 0.000 HEALTH PHYSICS PERSONNEL 0 0 0 0.000 0.000 0.000 SUPERVISORY PERSONNEL 0 0 0 0.000 0.000 0.000 ENGINEERING PERSONNEL 0 0 0 0.000 0.000 0.000 TOTALS MAINTENANCE PERSONNEL 8 368 802 0.615 25.399 65.249-OPERATING PERSONNEL 103 58 385 9.204 3.590 30.679 HEALTH PHYSICS PERSONNEL 57 9 75 12.136 0.644 8.915 SUPERVISORY PERSONNEL 6 2 28 0.256 0.026 0.729 ENGINEERING PERSONNEL 48 61 146 3.012 5.286 8.085 GRAND TOTAL 222 498 1436 25.223 34.945 113.657 Note: Only those persons who have a dose greater than zero (0) are included in the tots 1 category.
(2)
TABLE B PHILADELPHIA ELECTRIC COMPANY LIMERICK NUCLEAR GENERATING STATION POTTSTOWN, PA 19464 02/05/88 LICENSE NO. NPF - 39 RECORDED ANNUAL WHOLE BODY EXPOSURE FOR THE PERIOD 01/01/87 THRU 12/31/87 ANNUAL DOSE
- NUMBER OF INDIVIDUALS RANGES (REM) IN EACH RANGE STATION UTILITY CONTRACTOR TOTAL ,
NO MEASURABLE EXPOSURE 166 1318 4797 6281 MEASURABLE EXPOSURE LESS THAN 0.100 147 406 1093 1646 0.100 - 0.250 43 66 230 339 0.250 - 0.500 22 20 93 135 0.500 - 0.750 10 6 17 33 0.750 - 1.000 0 0 3 3 1.000 - 2.000 0 0 0 0 2.000 - 3.000 0 0 0 0 3.000 - 4.000 0 0 0 0 4.000 - 5.000 0 0 0 0 5.000 - 6.000 0 0 0 0 6.000 - 7.000 0 0 0 0 7.000 - 8.000 0 0 0 0 8.000 - 9.000 0 0 0 0 9.000 - 10.000 0 0 0 0 10.000 - 11.000 0 0 0 0 11.000 - 12.000 0 0 0 0 12.000 + 0 0 0 0 TOTAL NUMBER OF INDIVIDUALS REPORTED 388 1816 6233 8437 THE ABOVE INFORMATION IS SUBMITTED FOR THE TOTAL NUMBER OF INDIVIDUALS FOR WHOM PERSONNEL MONITORING WAS
() REQUIRED UNDER 10 CFR 20.202(A) OR 10 CFR 34.33(A)
DURING THE REPORTING PERIOD.
() PROVIDED DURING THE REPORTING PERIOD q INDIVIDUAL EXPOSURES EXACTLY EQUAL TO THE VALUE SEPARATING EXPOSURE RANGES SHALL BE REPORTED IN THE HIGHER RANGE.
(3)
-o 4
PHILADELPHIA ELECTRIC COMPANY 23O1 M ARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 (215)8414000 February 26, 1988 Docket No. 50-352 Mr. William T. Russell, Administrator Region I U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
Dear Mr. Russell:
Enclosed is a copy of Philadelphia Electric Company's
- Occupational Exposure Tabulation No. 4 for Limerick Generating Station Unit 1 for the period January 1, 1987 through December 31, 1987.
This report is being submitted in compliance with Annual Reporting Requirements of Technical Specification 6.9.1.5 of Operating License NPF-39 and of 10 CFR 20.407(b).
Very truly yours, gr4x Ad W. M. Alden j
Director Licensing Section Nuclear Support Department Enclosure cc: Addressee Director, Office of Resource Management, USNRC E. M. Kelly, Senior Site Inspector l
SESG l