Forwards Safety Evaluation & SER of Root Cause Findings & Corrective Actions Repts for Plans 5,6,7 & 15A & 15B Re Steam & Feedwater Rupture Control Sys & Source Range Nuclear Instrumentation,Respectively
Date released: 05/30/2020 Download: ML20137J676


SER Supporting Util Identification of Root Causes for Source Range Nuclear Instrumentation Channels Inoperability During 850609 Steam & Feedwater Line Rupture Control Sys Low Level Actuation & Corrective Actions Taken.Plant Restart Approved
ML20137J703
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/08/1986
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML20137J703 (7)
Safety Evaluation Supporting Util Identification of Root Causes for Spurious 850609 Steam & Feedwater Line Rupture Control Sys Low Level Actuation,Closure of MSIVs & Actions Taken to Prevent Recurrence.Plant Restart Acceptable
ML20137J689
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/08/1986
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML20137J689 (9)
Forwards Safety Evaluation & SER of Root Cause Findings & Corrective Actions Repts for Plans 5,6,7 & 15A & 15B Re Steam & Feedwater Rupture Control Sys & Source Range Nuclear Instrumentation,Respectively
ML20137J671
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/08/1986
From: Stolz J
Office of Nuclear Reactor Regulation
To: WILLIAMS J
TOLEDO EDISON CO.
References