on 781129 at 4:00 Pm,Due to Problem in Heluim Circulatory Sys,There Was a Minute Release of Radioactivity in Reactor Bldg.No Hazard to Public
ML20064G566
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 12/05/1978
From: Gaschler J
PUBLIC SERVICE CO. OF COLORADO
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 7812120089
Download: ML20064G566 (1)


Text

- f O- N 7

~'

public service company ce esemde J g P.O. BOX 840 DENVER, COLORADO 90201

- December 5,1978 2  ::

i4i 1  !!

E, il Mr. Jerome Saltzme.n, Chief .

Antitrust & Indemnity Group - - .'

Nuclear Reactor Pegulation hrM ,[

U. S. Nuclear Pegulatory Commission .

=

Washington, D. C. 23535 ,

e m 5

L Re: Docket No. 50-267, 70, 1278 ;O

Dear Mr. Saltzm.in :

This is to report an incident which occurred at our Fort St.

Vrain Station at approximately 4:00 p.m. on November 29, 1978.

Due to an operating problem in the helium circulator auxiliary system, there was a minute release of radioactivity in the reactor building,

.the safety of the employees was not jeopardized and there was no measurable release to the atmosphere. At no time was there any hazard to the public.

Very truly yours, k Las k &

J A. Gaschler Insurance Director JAG:ss 0Q s.- s s 3 g t