ML19330A527

From kanterella
Revision as of 13:40, 18 February 2020 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
LER 80-059/03L-0:on 800703,during Normal Shutdown Surveillance,Level Switches & Pressure Indicator Showed 128 Instruments Out of Calibr or Not Properly Operating.Caused by Instrument Drift.Instruments Recalibr.Two Replaced
ML19330A527
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 07/22/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19330A521 List:
References
LER-80-059-03L, LER-80-59-3L, NUDOCS 8007280524
Download: ML19330A527 (2)


Text

___ . - _ __ _ _ _ _ _ _ _ _ _

IJRC FORM 3rs. U. S. NUCLEAR REGULATORY COMMisSloN (7 77) s LICENSEE EVENT REPORT QONTQCL BLOCK: l i

l l l l 1 lh 6

(PLEASE PRINT OR TYPE ALL RECUlRED INFORMATION)

V 8 9 l N l UCENSEE Y l J CODEl A l F14l 1iSl@l 0 10 l-UCENSE l 0 l0 l0 l0 l -l 0l 0l25 Ol@l' NUMBER 26 hl il il 1l Il@l57 CAT UCENSE TYPE 40 l

54 l@

CON'T IoIiI Qu',"c! I L l@Q! 5 10 l0 lo l3 J 3 13 l@l0 17 10 l 3 l 8 l74 0 l@l017 75 l21218l 080l@

7 8 60 61 OOCKET NUM8ER 68 69 EVENT QATE REPORT Q ATE EVENT CESCRIPTION AND PROBABLE CONSEQUENCES h l a # 21 l During normal shutdown survelliance associated with control rod drive hydraulic l I o 12 l l control unit accumulator pressure swjtches, level switches and pressure indicator l io i4; [ revealed 118 of 411 Instruments out of calibration or not operating properly. No l

, to isi i significant hazard existed. See attachment for additional details. _

l 0 l6 l l l l o 171 1 I foisti . I 7 8 9 80 S$'c'E Tee'$ SLE$$E CcMechENT CCCE SL8 C'E S C E lo191 i R l B l@ lE l@ l El@ lX lX lX lX lX lXl@ lZl@ lZl@

SEQUENTIA OCCURRE*CE REPCRT R EVISION LERsRO EVENT YEAR R EPORT NO. CODE TYPE NC.

@ yug at 18 10 l

,_2 22 1-1 23 1015191 24 26 l/l I o f 31 28 29 IL I 30 l-l 10 I 32 27 Ji T N AC 0 CNP T M HOURS SB t FOR 8. SL LI E MA UF RER I33X l@l34Z l@ lZ l@ l36Z l@ l 0 l0 l0 l0 l 37 lY l@ l42Y l@ lNl@ l R l 1 l 4 l047lf) 35 40 di 43 44 CAUSE CESCRIPTION AND CORRECTIVE ACTIONS IiIoll Instrument drift was the orimary cause. Corrective action consisted of calibration I li li l l on 126 of 128 instruments. Two (2) were replaced. No additional action is reauired. I<

1 li l 2 I I See attachment for additional details. ll li l 31 l l l i 141 I i 7 8 9 80 STA  % POWER OTHER STATUS Ot RY CISCOVERY DESCRIPTtcN Iii5I[faj@ lOl0l0l@l NA l (,,B,_j@l Survei1 lance l v 8 '* " " **

AduviTY Co'0 RENT-RELEASE LOCADON CF RELEASE @

l' i I s' *I L2J @D ' OF RELEASELJJ@lAMOUNTOF n ACDVlTY I

@= I "

I PEnScNN!L ExPcSSES  !

~UM.ER Tv,E oESCRi, men @

li j 71 l 010 l 0 l@l Z l@l NA l

,ER$cNNEL ~2u'JiES NuuSER eESea,rveN@

li la l8 l90 l 0 l 0 inl@l12 7

NA 80 l

LOSS OF CR DAMAGE TO FACIUTY TYPE DESCRIPTION l i j 9 l l Z ]@l NA l 7 8 9 10 50 ISSU E CE CRIPTION j lv 210] l N fhl NA l lllllllllIl1l 8 9 to 68 69 80

~

a

. ~

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT DOCKET NO.50-333 ATTACHMENT TO LER 80- 059/03L-0 Page 1 of 1 During normal shutdown, surveillances on the instruments associated with the Control Rod Drive Hydraulic Control Unit Accumulator Pressure Switches, Level Detectors and Pressure Indicators revealed that 128 of 411 instruments were out of calibration or not operating properly.

Tabulated below is a summary of the instruments of concern and the results of the "as found" condition:

~

1. Hydraulic Control Unit Accumulator Pressure Switches (137 total instruments) 118 units out of tolerance as follows:

1 unit greater than 970 psig "

27 units between 939 to 930 psig i 37 units between 929 to 920 psig l 29 units between 919 to 910 psig 13 units between 909 to 900 psig 11 units less than 900 psig (lowest 880 psig)  !

Normal pressure switch set point is 940 to 970 psig Manufacturer: Barksdale -

NPR ICode B074

2. Hydraulic Control Unit Accumulator Level Switches (137 total Instruments) 6 units did not function 5 units were cleaned I unit was replaced Manufacturer: Gems - NPRD Code G050 3 Hydraulic Control Unit Accumulator Pressure Indicators (137 total instruments) 4 units were out of tolerance 3 units were adjusted
1 unit was replaced due to non-linearity 1

Manufacturer: Robertshaw - NPRD Code R290 The out of tolerance pressure switches are attributed to instrument l

drift. fThe improper position of the level switenes is attributed to l 2 normal wear and tear. The out of tolerance pressure indicators are ,j attributed to Instrument drif t with the exception of one instrument l which was non-linear and replaced at the End of Natural Life.

To prevent recurrence, calibration of these instruments has been scheduled on regular' surveillance interval. No additional action is required. The event did not represent a significant hazard to the public health and safety.

r

,, - , - . . - , , - - , - . . - - , , -