ML053270147
| ML053270147 | |
| Person / Time | |
|---|---|
| Site: | Columbia |
| Issue date: | 09/01/2005 |
| From: | Energy Northwest |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| M544, Rev 69 | |
| Download: ML053270147 (1) | |
Text
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PRM PRM-CAB-1 EL.618'-7" TE TT RB 606' 1 1 RE ELECTRICOOL TS PRM NOTES PRM-REC-1B 1B 2 PRM PRM-C-1B TIC PRM-AC-2 EL.618'-7" 1. ALL INSTRUMENTATION ON THIS DRAWING TO PRM-C-1C 1B FLOW TS RE ELECTRICOOL PRM BE PREFIXED BY "SGT" UNLESS SPECIFICALLY 23012 23011 23034 1
1C PRM-REC-1C TIC NOTED OTHERWISE, ie; K PRM 1C PRM-AC-1 TE K
FROM SECONDARY SUM LMTR FS FR EL.611'-10" TO PRM-C-1A PRM IS IDENTIFIED AS SGT-TE-9A CONTAINMENT PRESSURE 1A1 1A1 1A1 2A1 T T T PRM-RR-3 9A TO STRIP HEATER TO STRIP HEATER AUTO START RE CONT. ON SGT-ESH-1A SGT-ESH-2A CONTROL SYSTEM "A" ELECTRICOOL SIGNAL F, A, Z PRM-REC-1A DWG. 2. ISOLATION SIGNAL CODES RMS CONT. ON DWG. 1A TIC RMS INTERMEDIATE M545-3 M545-3 (K/4) RMS RMS SQRT PRM 1A RANGE SIGNAL A - REACTOR VESSEL LOW WATER LEVEL
- RMS PRM PROCESSING (F/11) F - HIGH DRYWELL PRESSURE RMS TC TC 1A1 STAND-BY-GAS TREATMENT UNIT TC TC T AUTO OPEN PRM-LCRM-1B 1A2 AUTO OPEN SIGNAL F, A, Z Z - HIGH RADIATION, REACTOR BUILDING 2A1 O/M SGT-FU-1A
- 1A1 2A2 SIGNAL F, A, Z DPIC PRM-RA-1B PRM-VENTILATION SYSTEM TS TS *
- COMP-1 3 TS TS TS TS
- TS TS 1A1 PRM-XAY-1B SGT-V-717 PRM SGT-V-719 FT C 1A31 1A41 MI *
- 1A21 1A11 2A11 2A21 2A41 2A31 MO O 25 HP 1/2"SGT(60)-1 MO O HIGH 3. FOR FLOW DIAGRAM LEGEND, SYMBOLS,
- * * * *
- 1A1 PRM-COMP-3 RANGE SIGNAL O/M TI C C AND ABBREVIATIONS SEE DRAWING M501 6A SEE TABLE 1 MI MI PROCESSING M
1A SGT-FLX-3 T (DIV I) PRM-LCRM-1C 1
EXCEPT AS NOTED HEREIN TS 3A A 5A FR A H EHO PRM H MV/I A PRM-RA-1C A MT d A A H A A A A SGT-V-5A1 1 A L H H 1A1 4. FILTER TEST INJECTION AND SAMPLING TS 1A H H H A L
H A 4000 18"SGT(1)-1 PRM-XAY-1C PRM SP
- L SGT-V-3A2 PRM-A C 16A TS FO POINT H CFM N.C. SAMPLE FLOW LOW IN-1 18"SGT(1)-1 1A SGT-V-711A SGT-V-713A SGT-V-731A RMS abc LOW C STACK FLOW HIGH SGT-V-709A C
- N.O. RANGE SIGNAL C C C C (DIV II) FE NOTE 6 NOTE 12 5. * - INSTRUMENTS AND ACCESSORIES FURNISHED
- TS (4457 ACFM) PROCESSING SGT-V-715A ME ME SGT-V-705A SP J AUTO OPEN TS ME TS TS 1A1 PRM-LCRM-1A CPL BY EQUIPMENT SUPPLIER. (CONTRACT #18) J SGT-V-707A 16A TI 1A1/2 SGT-AD-1A1 SGT-V-4A1 P814 (TYP)
SIGNAL F, A, Z DPIS DPIS DPIS 3A DPIS 1A3/4 5A 2A1/2 DPIS DPIS SGT-V-728 FIGURE 1 PRM-RA-1A 1 CONTROL ROOM ALL TAGS FOR CHECK VALVES WILL BE
- TI 2A3/4 FIS D TE
- 9A MO O
- PRM-CP-1 PRM-XAY-1A 1A 2A 3A
- 4A 5A 6A SGT-FN-1A1 (ZONE G/3) PRM FROM FURNISHED AND INSTALLED BY OWNER.
(NOTE 14) 10A SGT-SPV-2A * * * (DIV II) 2A2 C RW 525' GROUP
- 1A
- N.C PRM-CAB-2
(DIV I)
CODE
- (DIV I)
(F/1) 6. ALL PIPING, VALVES, AND ASSOCIATED AUTO CLOSE FROM ARM-RIS-34 SGT-ES-1 SGT-V-724 COMPONENTS ON THIS DWG. ARE CLASSIFIED ELECTRIC SIGNAL F, A, Z SGT-V-730A SGT-V-706A CONT. ON DWG.
SGT-V-714A SGT-V-704A SGT-V-708A SGT-V-710A SGT-V-712A HEATING TD AO O COIL RMS M545-2 (K/5) AS FOLLOWS EXCEPT 18"CEP(2)-1 AND AS SP ON A FROM ARM-RIS-33 C L NOTED OTHERWISE:
SGT-FLX-7 1A RE RI CONT. ON DWG.
- SGT-EHC-1A1 SGT-EHC-1A2 20.7kW SGT-HF-1A1 SGT-CF-1A1 SGT-HF-1A2 SEISMIC CATEGORY I SGT-CF-1A2 M543-1 (F/5)
SGT-MS-1A SGT-FL-1A SGT-V-2A 32 32 (DIV I) RIS RR QUALITY CLASS I ROOM AIR 4000 4000 CFM ARM ARM 0-4000 CFM 32 32 CODE GROUP B (CODE STAMP IS NOT REQ'D)
NO CFM ARM ARM A 18"CEP(2)-1 IS CLASSIFIED AS FOLLOWS:
(DIV II)
SGT-ESH-1A SGT-ESH-2A FO FROM ARM-RIS-33 (DIV I) 6 ACTIVATED CARBON C L HIGH EFFICIENCY CONT. ON DWG. T SEISMIC CATEGORY II 18"SGT(1)-1 18"SGT(1)-1 FILTER (HEPA)
NOTE ELEC STRIP IODINE ABSORBER CONT. ELEC STRIP (DIV. I) 2.1kW HEATER M543-1 (F/5) QUALITY CLASS II 2.1kW ON HEATER 4"SGT(3)-1 MOISTURE (DIV I)
DWG. CODE GROUP D SEE SEPARATOR A SEE TABLE 1 FROM H M557 PREFILTER 6 AUTO OPEN ARM-RIS-34 (H/3) SIGNAL F, A, Z CONT. ON DWG. 7 AIR QUANTITIES INDICATED AS CFM ARE 18"SGT(1)-1 NOTE 6 SEE SGT-V-55A H SF NOTE
- NOTE 6
- NOTE 6 * * * * * * * *
- SEE NOTE 6 * * * * * *
- RMS RMS 2 abc 8A1 6A1 FAN ARE ACFM. CONTRACTOR SHALL ADJUST 8A HIGH EFFICIENCY SGT(3)-1 SGT(1)-1 SEE
- SEE 10
- TE SEE 7A
- SEE NOTE 10 10 *
- FILTER (HEPA)
- NOTE VARIABLE INLET VANES AT FANS TO SUIT TS NOTE 10 NOTE 10 ME 6A TE TS 10 NOTE
- AUTO CLOSE RANGE OF 500 TO 4000 ACFM.
SEE d TS 2"(TYP) 1 1/2"FP(60)-1 7A1 7A1 SGT-V-54A 4A * * (DIV II) SIGNAL F, A, Z NOTE SGT-V-56A SGT-V-57A SGT-V-58A SGT-V-59A SGT-V-60A SGT-V-61A SGT-V-62A SGT-V-63A SGT-V-64A SGT-V-65A SGT-V-66A SGT-V-67A SGT-V-68A SGT-V-69A SGT-V-70A SGT-V-71A 6A1 C SGT-V-51A SGT-V-52A C SGT-FN-1A2 SGT-V-53A ME MO O MO O 8. ALL TAGS FOR INSTRUMENT ROOT VALVES
2"FP(60)-1 17A MV/I MV/I FE WILL BE FURNISHED AND INSTALLED BY 2"FP(60)-1
- C MT 6A 7A (DIV II) TO ATMOSPHERE OWNER.
- SGT-AD-1A2 1A2 T RB 648'-3" DWG. M515-5 (D/3)
MT TS 4A TS TS A SGT-V-5A2 8A1 H (4457 ACFM) 18"SGT(1)-1 9. ALL PRESSURE AND FLOW INSTRUMENT ROOT 18"SGT(1)-1 17A MS
- 7A (DIV I)
SIGNAL F, A, Z RMS A 6A REA RMS
- CLOSE H
VALVES NOT LABELED WILL BE 3/4" GLOBE DWG. M515-5 (D/4)
N.C.
SGT-V-716 18"SGT(1)-1 4A DWG M515-5 (D/3)
TI RSM A
H MI SGT-V-3A1 N.O.
NOTE 6 NOTE 12 VALVES UNLESS SPECIFICALLY NOTED 7A A A FO EHO 94 MI H H OTHERWISE.
4A AUTO SGT-FLX-4 FP-V-73 SGT-V-718 1A2 RB 647'-4" MO 7A TI FP-V-71 FT 10. DRAIN PIPING AS NOTED ONLY:
M 25 HP MO O 1/2"SGT(60)-1 SGT-1 LO 6A O FROM SECONDARY 1A2 SGT-V-4A2 FOR STACK SEISMIC CATEGORY I N.C.
LO.
C CONTAINMENT PRESSURE MONITOR DETAILS LO A H (DIV. II.) QUALITY CLASS I (MANUAL FULL BOX VALUE) CONTROL SYSTEM "B" 1A2 AUTO CLOSE SEE FIG I (J/4)
(DIV. I) SQ.RT SIGNAL F, A, Z CODE GROUP D G CONT. ON DWG.
G CEP-1 SGT-V-1A 2"SGT(50)-1 2"SGT(50)-1 M545-3 (G/6) RMS 1A2 T RE 11. ** INSTRUMENT AND ACCESSORIES RMS 18"CEP(2)-1 FP PS 2" FP N010 FURNISHED BY CONTRACT 215 AS PI 1/2" FP(60)-1 PS PI PS D17 A A A REPLACEMENT PARTS IDENTICAL TO (CROSS-TIE)
SUM LMTR FS FR SGT/8A1 SGT/8A1 FP SGT/6A1 SGT/6A1 FP SGT/7A1 FP EDR - TO FDR SYST. 1A2 1A2 1A2 2A2 PI FP RO ORIGINAL EQUIPMENT 1/2" 1/4" 1/2" 3/4" 1" 1/4" RMS FP 1/4" 3/4" 1/4" RMS 1/4" PI FP DWG. M539 (H/11)
EDR-TO FDR SYST SGT/7A2 SGT/7A1 TD A FROM REACTOR L
DWG M539 (H/10) FP-V-SGT/701A FP-V-SGT/702A FP FP-V-SGT/703A SGT/7A1 ON BLDG VENTILATION FP-ST-SGT/1A FP-ST-SGT/2A 16"SGT(1)-1 FP SYSTEM FP-V-SGT/13 FP-V-SGT/23 3/4" 1/4" C SQRT 23026 DPT FP-SPV-SGT/16 FP-V-SGT/34 FP-V-SGT/36 FP-SPV-SGT/26 FP AO FP AO (DIV II) CONT. ON DWG. 2 2 PRM T C (NOTE 16)
RO FP-V-SGT/16 RO FP-V-SGT/26 FP-ST-SGT/3A TE CONT.
SGT/16 (NOTE 16)
SGT/26 FP-V-SGT/33 RMS FP M545-3 (H/1) PRM 215 PRM FI SGT/8A1 (SEE NOTE 16) FP SGT/6A1 FP 1/4"MD(99)-1 C 8A SP 2 CONTAINMENT 1/4" 1/4" 1/2" AO FP-SPV-SGT/36 SEE DET. "A" RMS FROM 1/4"MD(99)-1 PI FP ATMOS. 1/4"MD(99)-1 ATMOS STACK FLOW 18"CEP(2)-1 (B\15) 2A 1/4" SEE DET. "A" SGT/36 SGT-V-726 1 PI PRIMARY SEE DET. "A" SGT/8A2 FP-V-SGT/14 FP-V-SGT/24 FP ATMOS OFF/ON (B/15) 216 PRM CONT. ON DWG. 0-4,000 CFM (B/15) DRAIN 1 L.O. FP-V-SGT/11 L.O. FP-V-SGT/21 1/2" SAMPLE FLOW M543-3 (J/9) PI CONTR.
DRAIN DRAIN CONT. ON DWG.
2" CONT. ON DWG. 2" CONT. ON DWG.
SGT/6A2 M510-2A (J/6) M510-2A (H/6)
F M510-2A (J/6) FP L.O. FP-V-SGT/31 PRM C F 18"CEP(2)-1 FROM 4"FP(60)-1 FROM 4"FP(60)-1 2" FROM 4"FP(60)-1 REA-V-100 REA-F-9A REA-F-10A PRM-P-1 FIT FE TO PRM-FR-1 DETAIL "D" CONT. ON DWG. M515-5 (D/2) CONT. ON DWG. M515-5 (D/3) DETAIL "C" DETAIL "B" SGT-V-727 (J/2)
SEE NOTE 17 CONT. ON DWG. M515-5 (D/3) SP 1 1B CONT. CONT. REA-V-20 FE PRM 2B TE REA-V-19 215 206 1A 4"SGT(3)-1 C PRM 8B FIRE WALL SEPARATION REA-F-9B REA-F-10B SEE NOTE SUM LMTR FS FR PRM-V-1 FROM SECONDARY 15 TO STRIP HEATER TO STRIP HEATER CONTAINMENT PRESSURE 1B2 1B2 1B2 2B2 AUTO START 6" FROM OFF-GAS SGT-ESH-1B SGT-ESH-2B CONTROL SYSTEM "B" PRM-CAB-2 SIGNAL F, A, Z RMS SIGNAL F, A, Z SYSTEM CONT.
CLOSE RMS RMS CONT. ON DWG. RB 606' ON DWG. M535-2 (K/1)
M545-3 (G/6) RMS NOTE 6 NOTE 16
- RMS SQRT TC RMS (DIV. II) RMS T 12. THIS SECTION OF LINE IS CLASSIFIED AS AUTO MI TC TC TC 1B2 CEP-1 MO O 1B2 FOLLOWS:
6B
- 1B1 2B1 2B2 AUTO OPEN C TS TS SIGNAL F, A, Z
- *
- DPIC AUTO OPEN SEISMIC CATEGORY I TS TS TS TS TS TS N.C. SGT-V-721 SIGNAL F, A, Z 18"SGT(1)-1 1B31 1B41 1B2 SGT-V-720 FT QUALITY CLASS I MT *
- 1B21 1B11 2B11 2B21 2B41 2B31 MO O 1/2"SGT(60)-1 MO O SGT-1 TI 1/2"SGT(60)-1 1B2 E CONT. 1B 16B SEE TABLE 1
- * * * *
- C 25HP C
CODE GROUP B*
E MI MI M 14"AR ON SGT-V-1B C A SGT-FLX-5 (DIV II) FROM OFF GAS SYSTEM 4"SGT(2)-1 MV/I
- H DWG. TS 3B A A 5B A A EHO T
CONT. ON DWG. M511 (K/15)
- NO CODE STAMP REQUIRED. DESIGN, TS A L H L H M557 H 1B ME d A H
A H
A H
A H
A (DIV I) 1B2 18"SGT(1)-1 SGT-V-5B2 FABRICATION, INSTALLATION, & EXAMINATION H
A (E/4) NOTE 6 1B
- L SGT-V-3B1 FO SHALL MEET THE REQUIREMENTS OF SGT-V-709B SGT-V-711B SGT-V-713B SGT-V-715B TS N.C.
RMS C 16B SGT-V-707B SF C
- abc ASME III-2. HOWEVER THE PNEUMATIC 4"SGT(2)-1 TI C N.O. FE SGT-V-705B 1 C C C C SEE NOTE 6 SEE NOTE 12
- TS TS (4457 ACFM) TEST IS WAIVED.
ME 9B AUTO OPEN 18"SGT(1)-1 A ME TI SP 1B2 SGT(2)-1 SGT(1)-1 H SGT-V-731B SIGNAL F, A, Z DPIS
- IB3/4 MO O 13. DELETED (TYP) 2B 3B 4B 5B 6B SGT-FN-1B2 18"SGT(1)-1 SGT-SPV-2B D * * * *
- 1B 2B1/2 * * (DIV. I.) 2B1 C
(DIV II)
GROUP N.C (DIV. II.)
SGT-ES-2 CODE (NOTE 14) AUTO CLOSE SGT-V-706B PREFILTER SGT-V-714B SGT-V-730B SGT-V-704B 20.7kW SGT-V-708B SGT-V-710B SGT-V-712B TD SIGNAL F, A, Z AO O ELECTRIC ON RMS C HEATING SGT-FLX-8 18"SGT(1)-1 SGT-EHC-1B1 COILS SGT-EHC-1B2 SGT-HF-1B1 SGT-CF-1B1 SGT-CF-1B2 SGT-HF-1B2
- 14. INSTRUMENT TUBING ON UNITS SGT-MS-1B SGT-FL-1B SGT-V-2B 0-4000 CFM SGT-FU-1A & 1B ARE CLASSIFIED AS ROOM AIR (DIV II) 4000 4000 CFM FOLLOWS:
D NO CFM D (DIV. II)
SGT-ESH-1B C
SGT-ESH-2B (DIV. I)
FO SEISMIC CATEGORY I 6 ACTIVATED CARBON HIGH EFFICIENCY A L
SP IODINE ADSORBER FILTER (HEPA) QUALITY CLASS I NOTE (DIV. II)
AUTO OPEN 18"SGT(1)-1 ELEC STRIP TABLE 1 2.1kW 1B ELEC STRIP SIGNAL F, A, Z 2.1kW
- HEATER CODE GROUP D HEATER (DIV. II)
SEE 20.7kW HIGH EFF.
SGT-V-725 MAIN HEATER TEMP SWITCHES FILTER (HEPA) 15. THE 20"x 20" DUCT (SHOWN AS DOTTED LINE a b c d SGT-V-55B SGT-V-60B CONTRACT 216) NO LONGER SERVES ANY 1ST STAGE 2ND STAGE 3RD STAGE OVERTEMP STAND-BY-GAS TREATMENT UNIT SEE
NOTE 6 NOTE 6 *
- NOTE 6
- NOTE 6 * * * * * *
- SGT-V-63B * * * * * * * *
- SEE
- 6B1
- SEE SGT-V-61B
- SEE THE EXTENSION OF THE 6"OFF-GAS LINE NOTE 10 ME NOTE 10 NOTE 10 10 NOTE 10 TS-EH1A11 TS-EH1A14 TS-EH1A17 TS-EH1A110 TE 2" NOTE 10 ME SGT-V-62B TE TS AUTO CLOSE (OG(28)-3) IS CLASSIFIED AS FOLLOWS:
(TYP)
NOTE 17B 6B SGT-EHC-1A1 TS-EH1A12 TS-EH1A15 TS-EH1A18 THRU 4B SIGNAL F, A, Z SEISMIC CATEGORY II
- SGT-V-59B 7B1
- 7B1
- (DIV II) TS-EH1A13 TS-EH1A16 TS-EH1A19 TS-EH1A118 SGT-V-64B SGT-V-65B SGT-V-66B SGT-V-67B SGT-V-68B SGT-V-69B SGT-V-70B SGT-V-71B TS SGT-V-53B SGT-V-54B (WITH SEISMIC CATEGORY I SUPPORTS) 1 1/2"FP(60)-1 SGT-V-51B SGT-V-52B MO O MO O SGT-V-58B C SEE MOISTURE 6B1 TS-EH1A21 TS-EH1A24 TS-EH1A27 TS-EH1A210
SEPARATOR MT SGT-EHC-1A2 TS-EH1A22 TS-EH1A25 TS-EH1A28 THRU SGT-V-57B C MV/T 7B SGT-AD-1B1 (DIV I) 1B1 (DIV I) CODE GROUP D +
17B T TS-EH1A23 TS-EH1A26 TS-EH1A29 TS-EH1A218
- 7B TS-EH1B11 TS-EH1B14 TS-EH1B17 TS-EH1B110 4B (4457 ACFM) 16. AIR OPERATED VALVE IS FAIL CLOSED AND DWG. M515-5 (C/2)
SGT-V-723 TS TS TI N.C. SGT-EHC-1B1 TS-EH1B12 TS-EH1B15 TS-EH1B18 THRU 18"SGT(1)-1 MI MS
- SEISMIC CATEGORY I C C abc A H 6B 7B SGT-V-3B2 N.O. TS-EH1B13 TS-EH1B16 TS-EH1B19 TS-EH1B118 C 2"FP(60)-1 7B A 4B NOTE 6 SEE NOTE 12 QUALITY CLASS I
- H TS-EH1B21 TS-EH1B24 TS-EH1B27 TS-EH1B210 TS EHO CODE GROUP C 2"FP(60)-1 SGT-FLX-6 MI SGT-V-722 d 1B1 SGT-EHC-1B2 TS-EH1B22 TS-EH1B25 TS-EH1B28 THRU SEE TABLE 1 A ALL OTHER COMPONENTS IN DETAIL ARE
TI H 1B1 SGT-V-4B1 C QC II, CODE GROUP D, SC II (SEE 15Q.
DWG. M515-5 (C/2)
N.C.
RMS 6B FROM SECONDARY (DIV. I) 215 SPEC FOR SUPPORTS, PG 15Q-49b).
CONTAINMENT PRESSURE DPIC A
H CONTROL SYSTEM A, DWG 1B1 SQRT AUTO CLOSE LEGEND
- 17. TRUE ORIENTATION IS OPPOSITE THAN SHOWN:
2"SGT(50)-1 2"SGT(50)-1 M545-3 (K/4) 1B1 SIGNAL F, A, Z RMS T RMS 1. ESH - ELECTRIC STRIP HEATER FACING INLET ENDS, "A" TRAIN IS ON THE FP-V-74 PI ED - EQUIPMENT DRAIN FP RIGHT, "B" TRAIN IS ON THE LEFT.
L.O. FP-V-75 L.O. FP-V-76 L.O.
EDR- TO FDR SYST EDR-TO FDR SYST SGT/8BI SUM LMTR FS FR DWG M539 (H/9) DWG M539 (H/10) 2. ALL VALVES SUFFIXED WITH A (TH) DENOTE A 1B1 1B1 1B1 2B1 THROTTLED VALVE REFERENCES TO CONTRACT NUMBERS, SUCH AS 2" FP-V-SGT/701B 215, 206, 220, FOUND IN THE NOTES ON THIS 1/4" MD(99)-1 FROM 1/4" MD(99)-1 FROM 3/4" TD PS FP 1/2" 3/4" A 1/4" L DRAWING REFER TO ORIGINAL CONSTRUCTION FP A ON DETAIL "B", ZONE (F/8) DETAIL "G", ZONE (B/10) CONTRACT CONTRACT 1/2" 3/4" 1/2" PS FP-V-SGT/53 SGT/7BI DESIGN REQUIREMENTS.
FP-V-SGT/63 1/4" MD(99)-1 FROM 1/4" MD(99)-1 FROM # 215 # 216 SGT/8BI FP-V-SGT/42 FP PI 1/4" PI FP 1/4" RMS CURRENT DESIGN REQUIREMENTS ARE DETAIL "C", ZONE (F/11) DETAIL "F", ZONE (A/11) FP B DOCUMENTED IN THE STATION DESIGN B 1/4" SGT/6BI SGT/7B1 FP-V-SGT/703B C FP-V-SGT/702B SPECIFICATIONS AND ACTIVE CONTRACT FP-ST-SGT/4A 1/4" MD(99)-1 FROM 1/4" MD(99)-1 (DIV I)
FP-V-SGT/46 CONT. ON DWG. A 1/2" SPECIFICATIONS WHICH STILL APPLY.
(NOTE 16)
DETAIL "D", ZONE (F/13) M545-3 (H/11)
RMS 1/4" FP-V-SGT/66 AO FP 1/2" FP-ST-SGT/6A FP (NOTE 16) 1/4" MD(99)-1 FROM 1/4" MD(99)-1 CONT. ON DWG. SGT/46 FP-SPV-SGT/66 1/4" FP-ST-SGT/5A AO PS FP DETAIL "E", ZONE (A/13) M545-3 (F/11) RO FP RMS FP A SGT/66 FP SGT/6BI FP-V-SGT/56 SGT/8B1 6"RD(2)-1 (NOTE 16) 3" 3" 1/4"MD(99)-1 ATMOS FSAR FIG.
LC SEE DET. "A" AO FP-SPV-SGT/56 3"MD(99)-1 (B/15) SGT/56 FP CONT. ON DWG.
3"MD-V-102 FP FP FP-V-SGT/64 RO RO 1/2" 1/4" 1/2" M510-2A (J/5)
ATMOS SGT/6B1 SGT/7B1 DRAIN SEAL DRAIN 2" 1/4"MD(99)-1 COLUMBIA FP-SPV-SGT/46 SEE DET. "A" FP-V-SGT/54 PI 1/4" FP DETAIL "A" (B/14) SGT/7B2 GENERATING ATMOS CONT. ON DWG.
PI 1/4" 1/2" L.O. STATION FP PI M510-2A (H/5)
SGT/8B2 FP-V-SGT/51 REV DATE DESCRIPTION DWN CHK APVD SIGNATURE DATE TITLE FP-V-SGT/44 CONT. ON DWG. SGT/6B2 FP FP-V-SGT/41 DRAIN 2" L.O.
A M510-2A (H/6) 1/4"MD(99)-1 L.O. FP-V-SGT/61 66 2-8-02 REDRAWN PER 01475-004. 4WT/BLS KL SRP APPROVED A
SEE DET. "A" 2" SCOTT PAYNE 2-8-02 FROM 4"FP(60)-1 67 9-12-02 REV PER 55-2887-0A-201 (B/8,10,12, G/9,10,12), 55-2887-0A-202 (B/8,10,12, G/9,10,12). BLS KL SRP 1 1/2" (B/14) FLOW DIAGRAM CONT. ON DWG. M515-5 (C/2) CHECKED FROM 4"FP(60)-1 68 9-21-04 REV PER 03261-200 (A/8-12, C/6-7,9-12, D/6-8, D-E/1-2, E/6, F/9-12, G/5-6, G-H/10-12, H/5-7, J/5-7). JFT HL DRJ HVAC-STANDBY GAS TREATMENT CONT. ON DWG. M515-5 (C/2) 69 9-1-05 REV PER 03587-200 (A-B/8-13, B/14-15, F-G/8-13) H.AL BLS DRJ K. LUCAS 2-7-02 REACTOR BUILDING FROM 4"FP(60)-1 DETAIL "F" DRAIN DRAWN B. L. STAFFORD 8-8-00 CONT. ON DWG. M515-5 (D/2) DETAIL "G" 4WARDTECH 6-17-99 DETAIL "E" SCALE DWG NO. REV.
N.T.S. M544 69 PDS2-E1 R0 (9/94) SERVER84\00\G 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1