MONTHYEARML17265A6921999-06-28028 June 1999 Application for Amend to License DPR-18 to Revise ITS Associated with RCS Leakage Detection Instrumentation.Lar Proposed as Result of Commitment That Rg&E Submit as Part of Staff Review of Application of leak-before-break Status ML17265A5691999-03-0101 March 1999 Application for Amend to License DPR-18,proposing Change in ITS to Revise Battery Cell Parameters Limit for Specific Gravity (SR 3.8.6.3 & SR 3.8.6.6) ML17265A4651998-11-24024 November 1998 Application for Amend to License DPR-18,revising Improved Tech Spec Description of Fuel Cladding Matl (TS 4.2.1) & Updating References Provided in TS 5.6.5 for COLR ML17265A2431998-04-27027 April 1998 Application for Amend to License DPR-18,revising Requirements Associated W/Sfp to Reflect Planned Mod to Storage Racks & Temporarily Addressing Boraflex Degradation within Pool ML17264B0431997-09-29029 September 1997 Application for Amend to License DPR-18,revising Administrative Controls W/Respect to RCS Pressure & Temp Limits Rept ML17264B0381997-09-29029 September 1997 Application for Amend to License DPR-18,revising TS Re Allowable Value & Trip Setpoint for High Steam Flow Input Into LCO Table 3.3.2-1,Function 4d (Main Steam Isolation) to Address Issues Identified in Revised Setpoint Analysis ML17264B0021997-08-19019 August 1997 Application for Amend to License DPR-18,allowing Testing of Certain ECCS motor-operated Valves in Mode 4 Which Currently Requires Entry in LCO 3.0.3 ML17264A9981997-08-19019 August 1997 Application for Amend to License DPR-18,correcting Specified Accumulator Borated Water Volume Values in SR 3.5.1.2 to Match Associated Accumulator Percent Level Values ML17264A8661997-04-24024 April 1997 Application for Amend to License DPR-18,revising RCP PT & Administrative Control Requirements ML17264A8471997-03-31031 March 1997 Application for Amend to License DPR-18,revising Spent Fuel Pool Storage Requirements ML20134D9911996-10-29029 October 1996 Application for Amend to License DPR-18,requesting Change to Mode of Applicability for Auxiliary Feedwater Pump Actuation on Main Feedwater Pump ML17264A7121996-10-29029 October 1996 Application for Amend to License DPR-18 Requesting Change to Required Actions for Inoperable Channels Associated with Auxiliary Feedwater Pump ML17264A5991996-09-13013 September 1996 Application for Amend to License DPR-18,revising RCS Pressure & Temp Limits Rept ML17264A4701996-05-0808 May 1996 Application for Amend to License DPR-18,correcting Typos ML17264A4041996-03-15015 March 1996 Application for Amend to License DPR-18,revising TS to Incorporate Methodology for Determining RCS P/T Limits & LTOP Limits in Administrative Controls Section of RCS P/T Limits Rept ML17264A3441996-02-0909 February 1996 Application for Amend to License DPR-18,revising TS Table 3.3.2-1,Function 5b, Feedwater Isolation,Sg Water Level - High to Raise Allowable Value & Trip Setpoint ML17264A3381996-02-0909 February 1996 Application for Amend to License DPR-18,revising TS to Incorporate Ref to Methodology for Determining LTOP Limits Into Administrative Controls Section for RCS PT Limits Rept ML17264A3331996-02-0909 February 1996 Application for Amend to License DPR-18,revising Requirements for Containment Closure During Mode 6 to Allow Use of Installed Overhead Door Assembly to Isolate Equipment Hatch Opening ML17264A3221996-01-26026 January 1996 Application for Amend to License DPR-18,incorporating Changes Necessary to Reflect Revised Nuclear Fuel Loading ML17264A2521995-11-27027 November 1995 Application for Amend to License DPR-18,revising TS to Implement 10CFR50,App J,Option B ML17264A2551995-11-20020 November 1995 Application for Amend to License DPR-18,submitting Changes to TS Instrumentation Requirements & Conversion to Improved TS ML17264A1501995-08-31031 August 1995 Application for Amend to License DPR-18,proposing Ts,By Implementing WCAP-10271,its Assoc Suppls & Other Re Changes W/Respect to RTS & ESFAS ML17263B0671995-05-26026 May 1995 Application for Amend to License DPR-18,revising TSs in Entirety to Convert to Improved TSs ML17263A9771995-03-13013 March 1995 Application for Amend to License DPR-18,to Revise TS 4.4.2.4.a to Replace Specific Leakage Testing Frequencies for Containment Isolation Valves ML17309A5501994-07-15015 July 1994 Application for Amend to License DPR-18,proposing TS 3.5, Providing NRC W/Opportunity to Communicate at Early Stage Any Concerns W/Respect to Differences from NUREG-1431 ML17263A7141994-06-24024 June 1994 Application for Amend to License DPR-18,re Upgrading of Administrative Controls Section 6 ML17263A7071994-06-15015 June 1994 Notarized Application for Amend to License DPR-18 Re Reactor Coolant Activity ML17263A6551994-05-23023 May 1994 Application for Amend to License DPR-18,increasing Allowable Reactor Coolant Activity Levels to Improved TS (NUREG-1431) ML17263A6411994-05-13013 May 1994 Application for Amend to License DPR-18,revising TS Administrative Controls Section 6.0 Consistent W/Improved TS ML17263A3181993-07-13013 July 1993 Application for Amend to License Revisions for License DPR-18 Re Removing Containment Isolation Valve Table 3.6-1 from TS ML17263A2081993-04-0505 April 1993 Application for Amend to License DPR-18,revising TS to Remove Containment Isolation Valve Table 3.6-1 & Maintain Required Listing in Updated FSAR ML17262B1171992-12-17017 December 1992 Application for Amend to License DPR-19,revising TS Sections 3.2 & 3.3 to Eliminate Use of High Concentration Boric Acid as safety-related Source of SI Pumps & Increasing Allowable Outage Times ML17262B0991992-11-30030 November 1992 Application for Amend to License DPR-18,revising TS to Remove Table of Containment Isolation Valves & Provide Ref in Bases to UFSAR ML17262B0571992-10-0808 October 1992 Corrected Application for Amend to License DPR-18,adding Addl Requirements to Auxiliary Electrical Sys TS & Action Statements for Instrument Bus Sys,Consisting of Notarized Page Two ML17262B0431992-10-0808 October 1992 Application for Amend to License DPR-18,adding Addl Requirements to Auxiliary Electrical Sys TS & Action Statements for Instrument Bus Sys,Per Guidance Provided in GL 91-11 Re Resolution of GI 48 ML17262B0201992-09-15015 September 1992 Application for Amend to License DPR-18,revising TS Sections 3.1.1.4,3.1.1.6,4.3.4 & Adding site-specific Basis Sections to Address GL 90-06 Re Resolution of Generic Issues 70 & 94 ML17262A9121992-06-22022 June 1992 Application for Amend to License DPR-18,revising TS 4.3.1 Per Guidance Provided in Generic Ltr 91-01, Removal of Schedule for Withdrawal of Reactor Vessel Matl Specimens from Ts. ML17262A8311992-04-23023 April 1992 Application for Amend to License DPR-18,changing TSs to Redefine Snubber Visual Insp Schedule,Per Generic Ltr 90-09 Guidance ML17262A8211992-04-21021 April 1992 Application for Amend to License DPR-18,instituting Std License Condition for Fire Protection Program & Removing Requirements for Fire Protection Sys from Tss,Per Guidance in Generic Ltrs 86-10 & 88-12 ML17262A7861992-03-23023 March 1992 Application for Amend to License DPR-18,revising Tech Spec Section 6.5.1, Plant Operations Review Committee Function. ML17262A7801992-03-20020 March 1992 Application for Amend to License DPR-18,revising TS 5.1 Figure 5.1-1 to Describe Rather than Depict Site Area Boundary to Evaluate Radiological Releases to Unrestricted Area ML17262A7901992-03-20020 March 1992 Application for Amend to License DPR-18,revising Tech Specs 6.9.1.2 & 6.9.2.5 ML17262A6321991-10-25025 October 1991 Application for Amend to License DPR-18 to Delete TS 5.1 & Figure 5.1-1 ML17262A5331991-06-20020 June 1991 Application for Amend to License DPR-18,to Incorporate Changes to Specifications & Action Statements for Offsite & Onsite Power Sources Available for Operation of Plant Auxiliaries ML17262A4121991-03-0808 March 1991 Application for Amend to License DPR-18,removing Table 3.6-1 Re Containment Isolation Valves from Tech Specs ML17262A3831991-02-15015 February 1991 Application for Amend to License DPR-18,revising Tech Specs to Modify Method of Locking Open Motor Operated Valve 856, Refueling Water Storage Tank Delivery Valve When Reactor Coolant Sys at or Above 350 F ML17262A3751991-02-15015 February 1991 Application for Amend to License DPR-18,revising Heatup/Cooldown Curves & Associated Low Temp Overpressure Protection Setpoint to Implement Reg Guide 1.99,Rev 2 Methodology ML17262A3721991-02-15015 February 1991 Application for Amend to License DPR-18,providing Clarification of Which QA Activities Subj to Audit Considerations & Changing Audit Frequency Described in Tech Spec 6.5.2.8d ML17262A3871991-02-15015 February 1991 Application for Amend to License DPR-18,revising Tech Spec Tables 3.5-5 & 4.1-5 Based on Mods to Radiation Monitoring Sys ML17262A2951991-01-14014 January 1991 Application for Amend to License DPR-18,changing Tech Specs to Limit Containment Internal Pressure to 1 Psig Vs 6 Psig Per Initial Condition Assumptions in Containment Integrity Analysis 1999-06-28
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML17265A6921999-06-28028 June 1999 Application for Amend to License DPR-18 to Revise ITS Associated with RCS Leakage Detection Instrumentation.Lar Proposed as Result of Commitment That Rg&E Submit as Part of Staff Review of Application of leak-before-break Status ML17265A5691999-03-0101 March 1999 Application for Amend to License DPR-18,proposing Change in ITS to Revise Battery Cell Parameters Limit for Specific Gravity (SR 3.8.6.3 & SR 3.8.6.6) ML17265A4651998-11-24024 November 1998 Application for Amend to License DPR-18,revising Improved Tech Spec Description of Fuel Cladding Matl (TS 4.2.1) & Updating References Provided in TS 5.6.5 for COLR ML17265A2431998-04-27027 April 1998 Application for Amend to License DPR-18,revising Requirements Associated W/Sfp to Reflect Planned Mod to Storage Racks & Temporarily Addressing Boraflex Degradation within Pool ML17264B0431997-09-29029 September 1997 Application for Amend to License DPR-18,revising Administrative Controls W/Respect to RCS Pressure & Temp Limits Rept ML17264B0381997-09-29029 September 1997 Application for Amend to License DPR-18,revising TS Re Allowable Value & Trip Setpoint for High Steam Flow Input Into LCO Table 3.3.2-1,Function 4d (Main Steam Isolation) to Address Issues Identified in Revised Setpoint Analysis ML17264B0021997-08-19019 August 1997 Application for Amend to License DPR-18,allowing Testing of Certain ECCS motor-operated Valves in Mode 4 Which Currently Requires Entry in LCO 3.0.3 ML17264A9981997-08-19019 August 1997 Application for Amend to License DPR-18,correcting Specified Accumulator Borated Water Volume Values in SR 3.5.1.2 to Match Associated Accumulator Percent Level Values ML17264A8661997-04-24024 April 1997 Application for Amend to License DPR-18,revising RCP PT & Administrative Control Requirements ML17264A8471997-03-31031 March 1997 Application for Amend to License DPR-18,revising Spent Fuel Pool Storage Requirements ML20134D9911996-10-29029 October 1996 Application for Amend to License DPR-18,requesting Change to Mode of Applicability for Auxiliary Feedwater Pump Actuation on Main Feedwater Pump ML17264A7121996-10-29029 October 1996 Application for Amend to License DPR-18 Requesting Change to Required Actions for Inoperable Channels Associated with Auxiliary Feedwater Pump ML17264A5991996-09-13013 September 1996 Application for Amend to License DPR-18,revising RCS Pressure & Temp Limits Rept ML17264A4701996-05-0808 May 1996 Application for Amend to License DPR-18,correcting Typos ML17264A4041996-03-15015 March 1996 Application for Amend to License DPR-18,revising TS to Incorporate Methodology for Determining RCS P/T Limits & LTOP Limits in Administrative Controls Section of RCS P/T Limits Rept ML17264A3441996-02-0909 February 1996 Application for Amend to License DPR-18,revising TS Table 3.3.2-1,Function 5b, Feedwater Isolation,Sg Water Level - High to Raise Allowable Value & Trip Setpoint ML17264A3381996-02-0909 February 1996 Application for Amend to License DPR-18,revising TS to Incorporate Ref to Methodology for Determining LTOP Limits Into Administrative Controls Section for RCS PT Limits Rept ML17264A3331996-02-0909 February 1996 Application for Amend to License DPR-18,revising Requirements for Containment Closure During Mode 6 to Allow Use of Installed Overhead Door Assembly to Isolate Equipment Hatch Opening ML17264A3221996-01-26026 January 1996 Application for Amend to License DPR-18,incorporating Changes Necessary to Reflect Revised Nuclear Fuel Loading ML17264A2521995-11-27027 November 1995 Application for Amend to License DPR-18,revising TS to Implement 10CFR50,App J,Option B ML17264A2551995-11-20020 November 1995 Application for Amend to License DPR-18,submitting Changes to TS Instrumentation Requirements & Conversion to Improved TS ML17264A1501995-08-31031 August 1995 Application for Amend to License DPR-18,proposing Ts,By Implementing WCAP-10271,its Assoc Suppls & Other Re Changes W/Respect to RTS & ESFAS ML17263B0671995-05-26026 May 1995 Application for Amend to License DPR-18,revising TSs in Entirety to Convert to Improved TSs ML17263A9771995-03-13013 March 1995 Application for Amend to License DPR-18,to Revise TS 4.4.2.4.a to Replace Specific Leakage Testing Frequencies for Containment Isolation Valves ML17309A5501994-07-15015 July 1994 Application for Amend to License DPR-18,proposing TS 3.5, Providing NRC W/Opportunity to Communicate at Early Stage Any Concerns W/Respect to Differences from NUREG-1431 ML17263A7141994-06-24024 June 1994 Application for Amend to License DPR-18,re Upgrading of Administrative Controls Section 6 ML17263A7071994-06-15015 June 1994 Notarized Application for Amend to License DPR-18 Re Reactor Coolant Activity ML17263A6551994-05-23023 May 1994 Application for Amend to License DPR-18,increasing Allowable Reactor Coolant Activity Levels to Improved TS (NUREG-1431) ML17263A6411994-05-13013 May 1994 Application for Amend to License DPR-18,revising TS Administrative Controls Section 6.0 Consistent W/Improved TS ML17263A3181993-07-13013 July 1993 Application for Amend to License Revisions for License DPR-18 Re Removing Containment Isolation Valve Table 3.6-1 from TS ML17263A2081993-04-0505 April 1993 Application for Amend to License DPR-18,revising TS to Remove Containment Isolation Valve Table 3.6-1 & Maintain Required Listing in Updated FSAR ML17262B1171992-12-17017 December 1992 Application for Amend to License DPR-19,revising TS Sections 3.2 & 3.3 to Eliminate Use of High Concentration Boric Acid as safety-related Source of SI Pumps & Increasing Allowable Outage Times ML17262B0991992-11-30030 November 1992 Application for Amend to License DPR-18,revising TS to Remove Table of Containment Isolation Valves & Provide Ref in Bases to UFSAR ML17262B0571992-10-0808 October 1992 Corrected Application for Amend to License DPR-18,adding Addl Requirements to Auxiliary Electrical Sys TS & Action Statements for Instrument Bus Sys,Consisting of Notarized Page Two ML17262B0431992-10-0808 October 1992 Application for Amend to License DPR-18,adding Addl Requirements to Auxiliary Electrical Sys TS & Action Statements for Instrument Bus Sys,Per Guidance Provided in GL 91-11 Re Resolution of GI 48 ML17262B0201992-09-15015 September 1992 Application for Amend to License DPR-18,revising TS Sections 3.1.1.4,3.1.1.6,4.3.4 & Adding site-specific Basis Sections to Address GL 90-06 Re Resolution of Generic Issues 70 & 94 ML17262A9121992-06-22022 June 1992 Application for Amend to License DPR-18,revising TS 4.3.1 Per Guidance Provided in Generic Ltr 91-01, Removal of Schedule for Withdrawal of Reactor Vessel Matl Specimens from Ts. ML17262A8311992-04-23023 April 1992 Application for Amend to License DPR-18,changing TSs to Redefine Snubber Visual Insp Schedule,Per Generic Ltr 90-09 Guidance ML17262A8211992-04-21021 April 1992 Application for Amend to License DPR-18,instituting Std License Condition for Fire Protection Program & Removing Requirements for Fire Protection Sys from Tss,Per Guidance in Generic Ltrs 86-10 & 88-12 ML17262A7861992-03-23023 March 1992 Application for Amend to License DPR-18,revising Tech Spec Section 6.5.1, Plant Operations Review Committee Function. ML17262A7801992-03-20020 March 1992 Application for Amend to License DPR-18,revising TS 5.1 Figure 5.1-1 to Describe Rather than Depict Site Area Boundary to Evaluate Radiological Releases to Unrestricted Area ML17262A7901992-03-20020 March 1992 Application for Amend to License DPR-18,revising Tech Specs 6.9.1.2 & 6.9.2.5 ML17262A6321991-10-25025 October 1991 Application for Amend to License DPR-18 to Delete TS 5.1 & Figure 5.1-1 ML17262A5331991-06-20020 June 1991 Application for Amend to License DPR-18,to Incorporate Changes to Specifications & Action Statements for Offsite & Onsite Power Sources Available for Operation of Plant Auxiliaries ML17262A4121991-03-0808 March 1991 Application for Amend to License DPR-18,removing Table 3.6-1 Re Containment Isolation Valves from Tech Specs ML17262A3831991-02-15015 February 1991 Application for Amend to License DPR-18,revising Tech Specs to Modify Method of Locking Open Motor Operated Valve 856, Refueling Water Storage Tank Delivery Valve When Reactor Coolant Sys at or Above 350 F ML17262A3751991-02-15015 February 1991 Application for Amend to License DPR-18,revising Heatup/Cooldown Curves & Associated Low Temp Overpressure Protection Setpoint to Implement Reg Guide 1.99,Rev 2 Methodology ML17262A3721991-02-15015 February 1991 Application for Amend to License DPR-18,providing Clarification of Which QA Activities Subj to Audit Considerations & Changing Audit Frequency Described in Tech Spec 6.5.2.8d ML17262A3871991-02-15015 February 1991 Application for Amend to License DPR-18,revising Tech Spec Tables 3.5-5 & 4.1-5 Based on Mods to Radiation Monitoring Sys ML17262A2951991-01-14014 January 1991 Application for Amend to License DPR-18,changing Tech Specs to Limit Containment Internal Pressure to 1 Psig Vs 6 Psig Per Initial Condition Assumptions in Containment Integrity Analysis 1999-06-28
[Table view] |
Text
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION, In the Matter of )
)
Rochester Gas and Electric Corporation ) Docket No 50 244 (R. E. Ginna Nuclear Power Plant, )
Unit No. 1) )
APPLICATION FOR AMENDMENT TO OPERATING LICENSE Pursuant to Section 50.90 of the regulations of the U.S. Nuclear Regulatory Commission (the "Commission" ), Rochester Gas and Electric Corporation ("RG&E"), holder of Provisional Operating License No.
DPR-18, hereby requests that Sections 3.1.4 and 4.1 be revised in the Technical Specifications set forth in Appendix A to that license. This request for a change in Technical Specifications is submitted in response to a letter dated September 24, 1981 from Mr. Dennis M. Crutchfield, Chief, Operating Reactors Branch No. 5 regarding reactor coolant system iodine activity The proposed technical specification change is set forth in Attachment A to this Application. A safety evaluation is set forth in Attachment B. This evaluation also demonstrates that the proposed change does not involve a significant change in the types or a significant increase in the amounts of effluents or any change in the authorized power level of the facility.
The proposed changes have been clearly identified as an NRC position in the NRC's Standard Technical Specifications for Westinghouse plants. Therefore a fee of $ 4,000 is required.
>>o>~>
>>ooososo6 05000244
'PDR.'ADQCK '": PDR
-'
.P ~
f Fr I F
It tt
WHEREFORE, Applicant respectfully requests that Appendix A to Provisional Operating License No. DPR-18 be amended in the form attached here to as Attachment A.
Rochester Gas and Electric Corporation By L. D. Whi e, Jr.
Executive Vice President Subscribed and sworn to before me on this l 7 day of May, 1982.
GARY L. EISS N RY PUBLIC, State of N. Y. Monroe Co.
hfy Commfssfon Expfres Marsh 30, 19~
I i re g ~ -,~p ) t~s .~ ',"3N 0 ~4
Attachment A 1 ~ Revise the Technical Specifications by replacing the following pages: 3.1-21,'.1-22, 3.1-23, 3.1-24, 4.1-8, 4.1-9, 4.1 2. Add page 4.1-12.
Maximum Coolant Activit S ecifications:
Whenever the reactor is critical or the reactor coolant average temperature is greater than 500oF:
- a. The total specific activity of the reactor coolant shall not exceed 84/EpCi/gm, where E is the average beta and gamma energies per disintegration in Mev.
- b. The I-131 equivalent of the iodine activity in the reactor coolant shall not exceed 1.0ju:i/gm.
cd The I-131 equivalent of the iodine activity on the secondary side of a steam generator shall not exceed 0 l~Ci/gm.
~
If the limit of 3.1.4.l.a is exceeded, then be subcritical with reactor coolant average temperature less than 500 F within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
a ~ If the I-131 equivalent activity in the reactor coolant exceeds the limit of 3 '.4.l.b but is less than the allowable limit shown on Figure 3.1.4-1, operation may continue for up to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> provided that the cumulative operating time under these circumstances does not exceed 800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> in any consecutive 12-month period.
If the I-131 equivalent activity in the reactor coolant exceeds the limit of 3.1.4 '.b for more than 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> in any consecutive 6-month period, 3 '-21 Amendment No ~ 8,rX8
then prepare and submit a Special Report to the Commission pursuant to Specification 6.9.2 within 30 days indicating the number of hours above this limit. The reactor may be taken critical or reactor coolant average temperature may be increased above a 500 F with the I-131 equivalent activity greater than the limit of 3.1.4.l.b as long as the provisions of this paragraph are met.
- b. If the I-131 equivalent activity exceeds the
'
limit of 3.1.4.1.b for more than 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> during one continuous time interval or exceeds the limit shown on Figure 3.1.4-1, be subcritical with reactor coolant average temperature less than 500oF within 8 hours.
c ~ If the I-131 equivalent activity exceeds the limit of 3.1.4.l.b, then perform sampling and analysis as required by Table 4.1-4, item 4a, until the activity is reduced to less than the limit of 3.1 4-1.b.
~
3-1.4.4 If the limit of 3.1.4.1."c is exceeded, then be at hot shutdown within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and in cold shutdown within the following 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />.
Basis:
The total activity limit for the primary system corresponds to operation with the plant design basis of 1% fuel defects.
Radiation shielding and the radioactive waste disposal systems 3 '-22 Amendment No. g5
were designed for operation with 1% defects . The limit for secondary iodine activity is conservatively established with
,respect to the limits on primary system iodine activity and primary-to-secondary leakage (Specification 3.1.5.2). If the activity should exceed the specified limits following a power transient the major concern would be whether additional fuel defects had developed bringing the total to above 1% defects.
Appropriate action to be taken to bring the activity within specification include one or more of the following: gradual decrease in power to a lower base power, increase in letdown flow rate, and venting of the volume control tank gases to the gas decay tanks.
The specified activity limits provide protection to the public against the potential release of reactor coolant activity to the atmosphere, as demonstrated by the analysis of a steam generator tube'upture accident. (3)
The 500 F temperature in the specification corresponds at saturation to 681 psia, which is below the set point of the secondary side relief valves. Therefore, potential primary to secondary leakage at a temperature below 500 F can be contained by closing the steam line isolation valves.
References:
(1) FSAR Table 9.2-5 (2) FSAR Section 11.1.3 (3) Letter dated September 24, 1981 from Dennis M. Crutchfield, USNRC, to John E. Maier, RGSE.
3.1-23
l~ jl~LL p
~
f t f I'1 Lf 25O ~.
~
H 200 UNACCEPl"ABl E M OPERATION O
O H
H O
150 'j O
O O
IX 100 0
O C4 R P-;CCf=PYAOLE 50 OPCPiA f ION H
CX I
H 0 ,J..
20 30 40 50 60 70 80 90 100 PERCENT OF RATED THERMAL POWER Figure 3.1.4-1 I-131 Equivalent, Reactor Coolant Specific Activity Limit Versus Percent of Rated Thermal Power with the Reactor Coolant Specific Activity 1.0pCi/gram I-131 Equivalent 3.1-24
TABLE 4. 1-2
'MINIMUM FREQUENCIES POR EQUIPMENT AND SAMPLING TESTS FSAR Section Reference Test Free@en~
- 1. Reactor Coolant Chloride and Fluoride 3 times/week Chemistry Samples and at least every third day 5 times/week and at least. every second day except when below 250oF
- 2. Reactor Coolant Boron concentration Weekly Boron
- 3. Refueling Water Boron concentration Weekly Storage Tank Water Sample
- 4. Boric Acid Tank Boron concentration Twice/week
- 5. Control Rods Rod drop times of all After vessel head full length rods I
removal and at least once per 18 months (1)
- 6. Full Length Control Mvement of at least 10 Monthly Rod steps in any one direc-tion for any rod not fully inserted
- 7. Pressurizer Safety Set point Each Valves Refueling shutdawn
- 8. Main Steam Safety Set point Each 10 Valves Re fueling shutdawn
- 9. Containment Functioning Each Refueling Isolation Trip Shutdawn
- 10. Refueling System Functioning Prior to Refueling 9.4.5 Interlocks Operations ll. Service Wat,er System Functioning Each Refueling Shutdawn 9.5.5
, 12. Fire Protection Pump Auctioning Monthly 9.5.5 and Pawer Supply 4.1-8 Amendment No. p,pp,yy,yp
FSAR Section Reference Test Fre~en~c
- 13. Spray Additive Tank NaOH Concent. monthly
- 14. Accumulator Boron Concentration Bi-Monthly
- 15. Primary System Evaluate Daily
~ge
- 16. Diesel Fuel Supply Fuel Inventory Daily 8.2.3
- 17. Spent Fuel Pit Boron Concentration monthly 9.5.5
- 18. Secondary Coolant Gross activity 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (2)(3)
Samples
- 19. Circulating Water Calibrate Each Refueling Flood Protection Shutdown Equignent Notes:
(1) Also required for specifically affected individual rods following any maintenance on or modification to the control rod drive system which could affect the drop time of those specific rods.
(2) Not required during a cold or refueling shutdown.
(3) An isotopic analysis for I-131 equivalent activity is required at least monthly whenever the gross activity determination indicates iodine concentration greater than lOS of the allowable limit but only once per 6 rmnths whenever the gross activity determination indicates iodine concentration below 10% of the allmrhle limit.
4.1-9 Amendment No . Q, gg, /gal
INTENTIONALLY BLANK 4.1-10
Attachment B The Technical Specification limits for reactor coolant system I-131 equivalent activity and for coolant activity sampling have been revised to be consistent with the NRC's Standard Technical Specifications for Westinghouse-designed plants. The activity limits are .conservative with respect to the assumptions used in the NRC's analysis of a steam generator tube rupture event which was provided to RGGE by letter dated September 24, 1981.
.i'v
'T i 0 TABLE 4.1-4 REACTOR COOLANT SPECIFIC ACTIVITY SAMPLE AND ANALYSIS PROGRAM TYPE OF MEASUREMENT SAMPLE AND ANALYSIS MODES IN WHICH SAMPLE AND ANALYSIS FREQUENCY AND ANALYSIS REQUIRED Gross Activity Determination At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Above cold shutdown (beta-gamma) (1) 2 ~ Isotopic Analysis for Dose 1 per 14 days Above 5t reactor power Equivalent I-131 Concentra-tion 3 Radiochemical for E 1 per 6 months (3) Above 5% reactor power Determination (2)
Isotopic Analysis for a) Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, whenever As required by Specificati'on Iodine Including I-131, the I-131 equivalent 3.1.4.3.c*
I-133, and I-135 activity exceeds the limit of 3.1 4.l.b
~
b) One sample between 2 and 6 Hot shutdown or above hours following a reactor power change exceeding 15 per-cent within a 1-hour period (1) A gross radioactivity analysis shall consist of the quantitative measurement of the total radio-activity of the primary coolant in units~i/gm. The total primary coolant activity shall be the sum of the degassed beta-gamma activity and the total of all identified gaseous activit'5 minutes after the primary system is sampled.
(2) A radiochemical analysis shall consist of the quantitative measurement of the activity for each radionuclide which is identified in the primary coolant 15 minutes after the primary system is sampled. The activities for the individual isotopes shall be used in the determination of E.
(3) Sample to be taken after a minimum of 2 EFPD and 20 days of power operation have elapsed since reactor was last subcritical for 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or longer.
- Except at refueling shutdown, sampling shall be continued until the activity of the reactor coolant system is restored to within its limits.