ML20055A955: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[05000311/LER-1982-049]]
| number = ML20055A955
| issue date = 06/30/1982
| title = LER 82-049/03L-0:on 820617,containment Fan Coil Units 21 & 25 Failed to Meet Svc Water Flow Requirements.Caused by Valve 21SW57 Tube Bundle Plugged W/American Oysters in Unit 21.Unit 25 Failed Due to Cracked Solder Joint
| author name = Frahm R
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
| docket = 05000311
| license number =
| contact person =
| document report number = LER-82-049-03L, LER-82-49-3L, NUDOCS 8207200171
| package number = ML20055A949
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 1
}}
 
=Text=
{{#Wiki_filter:m ,:,
(F77)
LICENSEE EVENT REPORT (PLEASE PRINT C3 TYPE ALL REtUlRED INFCT.MATl!N)
CON' TROL BLOCK:              l    l    l    l  l      lh 6
8 lNs lJ 7          9    l SLICENSEE lG lS    CODEl 2 l@16 ol ol -l Ol i4                            UCENSE0]NUMBER 0] Ol Ol -l Ol        26 0l@l26        4 l 1lTYPE LICENSE      1lJo1l 1l@l l
67 CAT 68 lg CON'T 7
0 1 s
ERCE 60 l0lSlOlOlO!3llI1hl0 Si            DOCKET NUMBER l6 l1 68    89 l7EVENT l8 l2  DATE l@l 0 l 6 l 3HEPORT 74      76 l 0 DATE l 8 l 2 sol@
EVENT DESCRIPTION AND PROBABLE CONSEQUENCES r  o l3l l On June 17, 1982, during routine surveillance, it was observed that the service water g O 3      lfl w to No. 21 Conta'inment Fan Coil Unit (CFCU)waslessthanrequiredbytheTechnica}
gSpecifications,'and Action Statement 3.6.2.3.a was entered.                                                        Later that day, No. 25                  g g ,
CFCU also failed to meet the service water flow requirements, and Action Statement gg                                                                                                                                                                        y 0 6      l 3.6.2.3.b was entered. These occurrences constituted operation in a degraded mode in                                                                      g gag,y gaccordance with Technical Specification 6.9.1.9.b.                                                                                                                g
, o ;g ; g (82-046, 82-041, 82-040, 82-039, 82-038)                                                                                                                      g 7      s9                                                                                                                                                              so SYSTEM              CAUSE          CAUSE                                                    COMP.          VALVE CODE              CODE        SUBCODE                  COMPONENT CODE                  SUBCODE        SU8 CODE Q
7      s lSlBlh d h e          io          is              12 h l Hl Tl El Xl Cl Hlh yh y h is                          is          is            20 SE QUENTI AL                    OCCURRENCE            REPORT                  REVISION EVENT YEAR                                REPORT NO.                            CODE              TYPE                      NO.
h "LER U    ROl 8 l 2l                  b              l 0l 4l 9l 26 y          l0l3l 28        29
{
Jo b          y 32 2i        22        23              24                      27                                              3i K N A      O            ON PL NT          ME                        HOURS          SB nT            FOR      B. SU PLI            MAN FACTURER l
33 D 34lggg                yg 35
                                                              ]36g            3l7 0l 0l 0l 0l      40 y g ] g di              42
                                                                                                                                          ] g 43 lWl1l2l0 g 44              47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h
[T]T] l The low flow to No. 21 CFCU was due to Valve 21SW57 tube bundle being plugged with                                                                                l lTJT'] l American oysters.                          The valve was cycled to eliminate the oysters by erosion.                                              No. 25      l 3 7      lCFCU failed due to a cracked solder joint in the back pressure square root extractor. l g l Joints subject to failure were resoldered. In both cases, the CFCU.was satisfactorilyg gtested, and the respective action statement terminated.                                                                                                      g 7      s 9                                                                                                                                                              S3 SA $              % POWER                        OTHER STATUS              Di$ 0 RY                            DISCOVERY DESCRIPTION l1l55            b h l1l0l0l@l                                NA                    l    d @l Surveillance Testing                                                    l ACTIVITY      CO$ TENT f ELE ASED OF RELE ASE                      AMOUNT OF ACTIVITY                                                    LOCATION OF RELE ASE 7
1 6 a e
[h dgl      io            si NA 44 l          l 45 NA                                                                _l 80 PERSONNEL EXPOSURES NUMBER            TYPE          DESCRIPTION I
EIB I Ol 01 Ol@l zl@l                                    Na PE RSONNE L INJU ^  IES NUVBER              OESCRIPTION I
7 i a se I d 0l 0l@l  si        ir NA so LOSS OF OR DAMAGE TO FACILITY TYPE      DESCRIPTION b Wh!
7      8 9            to NA so PusticiTv                          8207200171 820630                                                                              NRC USE ONLY iS          DESCRIPTION                PDR ADOCK 05000311 3 [SUEDy_jhl                    NA                  S                                PDR                                              l    l 1 l l l l l l l l l l l 7.3 7      s e            io                                  .
se so.                    ,,    so s
* NAME OF PREPARER                      R._Frahm                                            .
PHONE:        (609) 541-5000 PO                    4}}

Latest revision as of 03:20, 15 March 2020