ENS 54484: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 21: | Line 21: | ||
The licensee determined that poor camera maintenance and personnel error contributed to the guide tube being only partially connected to the camera which led to the disconnect. The radiography crew was briefed on the cause of the event and the proper steps to maintain and inspect a camera prior to use. | The licensee determined that poor camera maintenance and personnel error contributed to the guide tube being only partially connected to the camera which led to the disconnect. The radiography crew was briefed on the cause of the event and the proper steps to maintain and inspect a camera prior to use. | ||
The camera was a SPEC 150, serial number 2592 , with a 66 Ci Ir-192 source, serial number AK 2405. | The camera was a SPEC 150, serial number 2592 , with a 66 Ci Ir-192 source, serial number AK 2405. | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/ | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200128en.html#en54484 | ||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Revision as of 08:30, 28 January 2020
Where | |
---|---|
Iris Ndt Mandan, North Dakota (NRC Region 4) | |
License number: | 33-56806-01 |
Organization: | North Dakota Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+707.75 h29.49 days <br />4.213 weeks <br />0.969 months <br />) | |
Opened: | David Stradinger 17:00 Jan 17, 2020 |
NRC Officer: | Howie Crouch |
Last Updated: | Jan 17, 2020 |
54484 - NRC Website | |