{{#Wiki_filter:}} | {{#Wiki_filter:TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A SUMMARY DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY | ||
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1. | |||
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971) | |||
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA | |||
2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS | |||
2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS | |||
==4.0 REFERENCES== | |||
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View | |||
6A-2 Met Ed - Total House | |||
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section | |||
6A-5 Fan High Pressure Test Duct | |||
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A SUMMARY DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY | |||
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1. | |||
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971) | |||
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA | |||
2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS | |||
2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS | |||
==4.0 REFERENCES== | |||
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View | |||
6A-2 Met Ed - Total House | |||
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section | |||
6A-5 Fan High Pressure Test Duct}} |
Revision as of 16:35, 28 May 2018
ML16127A500 | |
Person / Time | |
---|---|
Site: | Three Mile Island |
Issue date: | 04/11/2016 |
From: | Exelon Generation Co |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML16127A520 | List:
|
References | |
TMI-16-035 | |
Download: ML16127A500 (22) | |
Text
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A SUMMARY DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1.
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA
2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS
2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS
4.0 REFERENCES
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View
6A-2 Met Ed - Total House
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
6A-5 Fan High Pressure Test Duct
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A SUMMARY DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1.
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA
2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS
2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS
4.0 REFERENCES
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View
6A-2 Met Ed - Total House
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
6A-5 Fan High Pressure Test Duct