{{#Wiki_filter:TMI-1 UFSAR  APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A  SUMMARY DESCRIPTION  THREE MILE ISLAND NUCLEAR STATION UNIT 1  REACTOR BUILDING FAN COOLER ASSEMBLY 
 
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1.
 
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
 
TMI-1 UFSAR  APPENDIX 6A 6A-ii REV. 18, APRIL 2006  TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA
 
2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS
 
2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS
 
==4.0 REFERENCES==
 
TMI-1 UFSAR  APPENDIX 6A 6A-iii REV. 18, APRIL 2006  LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View
 
6A-2 Met Ed - Total House
 
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
 
6A-5 Fan High Pressure Test Duct
 
TMI-1 UFSAR  APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A  SUMMARY DESCRIPTION  THREE MILE ISLAND NUCLEAR STATION UNIT 1  REACTOR BUILDING FAN COOLER ASSEMBLY 
 
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1.
 
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
 
TMI-1 UFSAR  APPENDIX 6A 6A-ii REV. 18, APRIL 2006  TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA
 
2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS
 
2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS
 
==4.0 REFERENCES==
 
TMI-1 UFSAR  APPENDIX 6A 6A-iii REV. 18, APRIL 2006  LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View
 
6A-2 Met Ed - Total House
 
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
 
6A-5 Fan High Pressure Test Duct}}

Revision as of 16:35, 28 May 2018

022_06 Appendix 06A Reactor Building Fan Cooler Assembly
ML16127A500
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 04/11/2016
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16127A520 List: ... further results
References
TMI-16-035
Download: ML16127A500 (22)


Text

TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A SUMMARY DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY

The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1.

(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)

TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA

2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS

2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS

4.0 REFERENCES

TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View

6A-2 Met Ed - Total House

6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section

6A-5 Fan High Pressure Test Duct

TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A SUMMARY DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY

The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island Nuclear Station Unit 1.

(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)

TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS Section 1.0 GENERAL 1.1 OPERATING ENVIRONMENT 2.0 SEISMIC DESIGN DESCRIPTION 2.1 GENERAL APPROACH 2.1.1 CRITERIA

2.2 METHOD 2.2.1 GENERAL 2.2.2 PROCEDURE 2.2.3 UTILIZATION 2.2.4 DETAILED ANALYSIS

2.3 RESULTS 2.4 SUMMARY 3.0 DESIGN SUMMARIES - MAJOR COMPONENTS 3.1 HOUSINGS 3.2 RELIEF VALVES 3.3 MIST ELIMINATORS 3.4 COILS 3.5 FAN MOTOR UNITS 3.5.1 FANS 3.5.2 MOTORS

4.0 REFERENCES

TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES Figure Title 6A-1 Reactor Building Fan Assembly-External View

6A-2 Met Ed - Total House

6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program 6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section

6A-5 Fan High Pressure Test Duct