| event date = 12/17/2003 03:15 PST | | event date = 12/17/2003 03:15 PST | ||
| last update date = 12/17/2003 | | last update date = 12/17/2003 | ||
| title = Technical Specification Required Shutdown Due | | title = Technical Specification Required Shutdown Due to Loss of Both Trains of Safety Injection | ||
| event text = The following information was obtained from the licensee via facsimile: | | event text = The following information was obtained from the licensee via facsimile: | ||
1. SYSTEMS AFFECTED: High Pressure Safety Injection (HPSI), Low Pressure Safety Injection (LPSI), Recirculation Actuation [System] (RAS), Containment Spray (CS). | 1. SYSTEMS AFFECTED: High Pressure Safety Injection (HPSI), Low Pressure Safety Injection (LPSI), Recirculation Actuation [System] (RAS), Containment Spray (CS). |
Latest revision as of 21:24, 1 March 2018
Where | |
---|---|
San Onofre California (NRC Region 4) | |
Reporting | |
10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown | |
Time - Person (Reporting Time:+-2.67 h-0.111 days <br />-0.0159 weeks <br />-0.00366 months <br />) | |
Opened: | John Braisted 08:35 Dec 17, 2003 |
NRC Officer: | Howie Crouch |
Last Updated: | Dec 17, 2003 |
40396 - NRC Website
| |