ML18142B034: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(2 intermediate revisions by the same user not shown)
Line 9: Line 9:
| docket = PROJ0753
| docket = PROJ0753
| license number =  
| license number =  
| contact person = Honcharik M C
| contact person = Honcharik M
| package number = ML18142B058
| package number = ML18142B058
| document type = Meeting Briefing Package/Handouts
| document type = Meeting Briefing Package/Handouts
| page count = 3
| page count = 3
| project =
| stage = Meeting
}}
}}


=Text=
=Text=
{{#Wiki_filter:Examination of Traveler Review Time 2016-2018 Page 1 EXCEL Services Corporation 160 approved LARs to adopt travelers Average review time (Submittal to Approval): 308 days (< 10 months)
{{#Wiki_filter:TSTF Number                                                            TSTF Title                                    Adoption (Approvals Submittals TSTF-358, Rev. 6  Missed Surveillance Requirements                                                                        100%
Excluding Vogtle TSTF
TSTF-369, Rev. 1  Removal of Monthly Operating Report and Occupational Radiation Exposure Report                          100%
-505 review (1,565 days) 35 (22%) review time over 1 year (Average 480 days, 15.8 months) 16 (10%) review over 13 months (Average 525 days, 17.25 months)
TSTF-413, Rev. 0  Elimination of Requirements for a Post Accident Sampling System (PASS) (NEDO-3299)                      100%
Traveler Adoption Review Time > 13 months Plant Name TSTF Number Approval Date Submit tal Date Review Time Hatch 1 & 2 TSTF-500-A, Rev. 2 08/29/17 08/11/15 749 Cook 1 & 2 TSTF-490, Rev.
TSTF-442, Rev. 0  Elimination of Requirements for a Post Accident Sampling System (PASS)                                  100%
0 10/20/16 11/14/14 706 Perry TSTF-425, Rev.
TSTF-449, Rev. 4  Steam Generator Tube Integrity                                                                          100%
3 02/23/16 03/25/14 700 Columbia TSTF-425, Rev.
TSTF-479, Rev, 0  Changes to Reflect Revision of 10CFR50.55a                                                              100%
3 11/02/16 03/17/15 596 Susquehanna 1 & 2 TSTF-425, Rev.
TSTF-497, Rev, 0  Limit Inservice Testing Program SR 3.0.2 Application to Frequencies of 2 Years or Less                  100%
3 05/20/16 10/26/14 572 Columbia TSTF-423, Rev.
TSTF-448, Rev. 3  Control Room Habitability                                                                                98%
1 02/03/16 08/12/14 540 Brunswick 1 & 2 TSTF-425, Rev.
TSTF-366, Rev. 0  Elimination of Requirements for a Post Accident Sampling System (PASS)                                  97%
3 05/24/17 12/21/15 520 Fermi TSTF-545, Rev.
TSTF-447, Rev. 1  Elimination of Hydrogen Recombiners and Change to Hydrogen and Oxygen Monitors                          97%
3 11/29/17 07/25/16 492 Cook 1 & 2 TSTF-425, Rev.
TSTF-535, Rev. 0  Revise Shutdown Margin Definition to Address Advanced Fuel Designs                                      92%
3 03/31/17 12/14/15 473 Harris TSTF-425, Rev.
TSTF-404, Rev. 0  SDV Actions                                                                                              92%
3 11/29/16 08/18/15 469 Hatch 1 & 2 TSTF-523-A, Rev. 2 04/16/16 01/13/15 459 Watts Bar Unit 2 TSTF-547, Rev.
TSTF-460, Rev. 0  Control Rod Scram Time Testing Frequency                                                                88%
1 02/13/18 11/23/16 447 Nine Mile Point 1 TSTF-425, Rev.
TSTF-542,Rev. 2    Reactor Pressure Vessel Water Inventory Control                                                          88%
3 05/31/16 03/26/15 432 Farley 1 & 2 TSTF-432, Rev.1 06/10/16 04/13/15 424 Surry 1 & 2 TSTF-523-A, Rev. 2 02/29/16 01/14/15 411 Waterford 3 TSTF-425, Rev.
TSTF-359, Rev. 9  Increase Flexibility in MODE Restraints                                                                  84%
3 07/26/16 06/17/15 405 Examination of Traveler Review Time 2016-2018 Page 2 EXCEL Services Corporation TSTF-425, 10 submittals, average of 493 days (16 months)
TSTF-425, Rev. 3  Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5b                            84%
Examining the three TSTF
TSTF-511, Rev. 0  Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 2              83%
-425 approvals in 2017:
TSTF-510-A, Rev. 2 Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection                    80%
Brunswick submitted 3 supplements and 5 RAI responses D.C. Cook submitted 2 supplements and 4 RAI responses Cooper had no supplements and one RAI response 0 100 200 300 400 500 600 700 800TSTF-425 Review Time vs. Approval Date}}
TSTF-484, Rev. 0  Use of TS 3.10.1 for Scram Time Testing Activities.                                                      79%
TSTF-426, Rev. 5  Revise or Add Actions to Preclude Entry into LCO 3.0.3 - RITSTF Initiatives 6b & 6c                    71%
TSTF-421, Rev. 0  Revision to RCP Flywheel Inspection Program (WCAP-15666)                                                69%
TSTF-545, Rev. 3  TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing        69%
TSTF-523-A, Rev. 2 Generic Letter 2008-01, Managing Gas Accumulation                                                        63%
TSTF-372, Rev. 4  Addition of LCO 3.0.8, Inoperability of Snubbers                                                        60%
TSTF-370, Rev. 0  Increase accumulator Completion Time from 1 hour to 24 hours (WCAP-15049)                                60%
TSTF-522, Rev. 0  Revise Ventilation System Surveillance Requirements to Operate for 10 hours per Month                  59%
TSTF-490, Rev. 0  Deletion of E Bar Definition and Revision to RCS Specific Activity Tech Spec                            58%
N/A                Elimination of Typical License Condition Requiring Reporting of Violations of Section 2.C              56%
TSTF-476, Rev. 1  Improved BPWS Control Rod Insertion Process (NEDO-33091)                                                54%
TSTF-477, Rev. 3  Add Action for Two Inoperable Control Room AC Subsystems                                                50%
TSTF-423, Rev. 1  Technical Specifications End States, NEDC-32988-A                                                        46%
TSTF-514, Rev. 3  Revise BWR Operability Requirements and Actions for RCS Leakage Instrumentation                        46%
TSTF-374, Rev. 0  Revision to TS 5.5.13 and associated TS Bases for Diesel Fuel Oil                                      45%
TSTF-486, Rev. 2  Revise MTC Surveillance for Startup Test Activity Reduction (STAR) Program (WCAP-16011)                  43%
TSTF-551, Rev. 3  Revise Secondary Containment Surveillance Requirements                                                  42%
TSTF-513, Rev. 3  Revise PWR Operability Requirements and Actions for RCS Leakage Instrumentation                          40%
TSTF-529, Rev. 4  Clarify Use and Application Rules                                                                        38%
TSTF-427, Rev. 2  Allowance for Non Technical Specification Barrier Degradation on Supported System OPERABIL              38%
TSTF-475, Rev. 1  Control Rod Notch Testing Frequency and SRM Insert Control Rod Action                                  38%
TSTF-491, Rev. 2  Removal of Main Steam and Main Feedwater Valve Isolation Times From Technical Specificatio              38%
TSTF-422, Rev. 2  Change in Technical Specifications End States (CE NPSD-1186)                                            29%
TSTF-487, Rev. 1  Relocate DNB Parameters to the COLR                                                                      29%
TSTF-501, Rev. 1  Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control                                28%
TSTF-547, Rev. 1  Clarification of Rod Position Requirements                                                              28%
TSTF-412, Rev. 3  Provide Actions for One Steam Supply to Turbine Driven AFW/EFW Pump Inoperable                          26%
TSTF-430, Rev. 0  AOT Extension to 7 Days for LPI and Containment Spray (BAW-2295-A, Rev. 1)                              25%
TSTF-431, Rev. 3  Change in Technical Specifications End States (BAW-2441)                                                25%
TSTF-432, Rev.1    Change in Technical Specifications End States (WCAP-16294)                                              21%
TSTF-500-A, Rev. 2 DC Electrical Rewrite - Update to TSTF-360                                                              20%
TSTF-493, Rev. 4  Clarify Application of Setpoint Methodology for LSSS Functions                                          16%
TSTF-478, Rev. 2  BWR Technical Specification Changes that Implement the Revised Rule for Combustible Gas Co              13%
TSTF-505-A, Rev. 1 Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b                                    9%
TSTF-446, Rev. 3  Risk Informed Evaluation of Extensions to Containment Isolation Valve Completion Times (WCAP-15791)      7%
TSTF-546, Rev. 0  Revise APRM Channel Adjustment Surveillance Requirement                                                  4%
TSTF-409, Rev. 2  Containment Spray System Completion Time Extension (CE NPSD-1045-A)                                      0%
TSTF-454, Rev. 1  Increase PCIV Completion Times from 4 hours, 24 hours, and 72 hours to 7 days (NEDC-33046)                0%
TSTF-498, Rev. 1  Risk-Informed Containment Isolation Valve Completion Times (BAW-2461)                                    0%
Green Underline - Risk Informed Red Underline - NRC Initiated or Requirement
 
Examination of Traveler Review Time 2016-2018 160 approved LARs to adopt travelers Average review time (Submittal to Approval): 308 days (< 10 months)
Excluding Vogtle TSTF-505 review (1,565 days)
* 35 (22%) review time over 1 year (Average 480 days, 15.8 months)
* 16 (10%) review over 13 months (Average 525 days, 17.25 months)
Traveler Adoption Review Time > 13 months Plant Name         TSTF Number       Approval       Submittal  Review Date           Date     Time Hatch 1 & 2             TSTF-500-A,       08/29/17       08/11/15     749 Rev. 2 Cook 1 & 2               TSTF-490, Rev. 10/20/16           11/14/14     706 0
Perry                   TSTF-425, Rev. 02/23/16           03/25/14     700 3
Columbia                 TSTF-425, Rev. 11/02/16           03/17/15     596 3
Susquehanna 1 & 2       TSTF-425, Rev. 05/20/16           10/26/14     572 3
Columbia                 TSTF-423, Rev. 02/03/16           08/12/14     540 1
Brunswick 1 & 2         TSTF-425, Rev. 05/24/17           12/21/15     520 3
Fermi                   TSTF-545, Rev. 11/29/17           07/25/16     492 3
Cook 1 & 2               TSTF-425, Rev. 03/31/17           12/14/15     473 3
Harris                   TSTF-425, Rev. 11/29/16           08/18/15     469 3
Hatch 1 & 2             TSTF-523-A,       04/16/16       01/13/15     459 Rev. 2 Watts Bar Unit 2         TSTF-547, Rev. 02/13/18           11/23/16     447 1
Nine Mile Point 1       TSTF-425, Rev. 05/31/16           03/26/15     432 3
Farley 1 & 2             TSTF-432,         06/10/16       04/13/15     424 Rev.1 Surry 1 & 2             TSTF-523-A,       02/29/16       01/14/15     411 Rev. 2 Waterford 3             TSTF-425, Rev. 07/26/16           06/17/15     405 3
Page 1              EXCEL Services Corporation
 
Examination of Traveler Review Time 2016-2018 TSTF-425, 10 submittals, average of 493 days (16 months)
TSTF-425 Review Time vs. Approval Date 800 700 600 500 400 300 200 100 0
Examining the three TSTF-425 approvals in 2017:
* Brunswick submitted 3 supplements and 5 RAI responses
* D.C. Cook submitted 2 supplements and 4 RAI responses
* Cooper had no supplements and one RAI response Page 2            EXCEL Services Corporation}}

Latest revision as of 16:47, 15 November 2019

May 17, 2018, Meeting Agenda Item 3.A - Traveler Adoption
ML18142B034
Person / Time
Site: Technical Specifications Task Force
Issue date: 05/17/2018
From:
Technical Specifications Task Force
To:
Office of Nuclear Reactor Regulation
Honcharik M
Shared Package
ML18142B058 List:
References
Download: ML18142B034 (3)


Text

TSTF Number TSTF Title Adoption (Approvals Submittals TSTF-358, Rev. 6 Missed Surveillance Requirements 100%

TSTF-369, Rev. 1 Removal of Monthly Operating Report and Occupational Radiation Exposure Report 100%

TSTF-413, Rev. 0 Elimination of Requirements for a Post Accident Sampling System (PASS) (NEDO-3299) 100%

TSTF-442, Rev. 0 Elimination of Requirements for a Post Accident Sampling System (PASS) 100%

TSTF-449, Rev. 4 Steam Generator Tube Integrity 100%

TSTF-479, Rev, 0 Changes to Reflect Revision of 10CFR50.55a 100%

TSTF-497, Rev, 0 Limit Inservice Testing Program SR 3.0.2 Application to Frequencies of 2 Years or Less 100%

TSTF-448, Rev. 3 Control Room Habitability 98%

TSTF-366, Rev. 0 Elimination of Requirements for a Post Accident Sampling System (PASS) 97%

TSTF-447, Rev. 1 Elimination of Hydrogen Recombiners and Change to Hydrogen and Oxygen Monitors 97%

TSTF-535, Rev. 0 Revise Shutdown Margin Definition to Address Advanced Fuel Designs 92%

TSTF-404, Rev. 0 SDV Actions 92%

TSTF-460, Rev. 0 Control Rod Scram Time Testing Frequency 88%

TSTF-542,Rev. 2 Reactor Pressure Vessel Water Inventory Control 88%

TSTF-359, Rev. 9 Increase Flexibility in MODE Restraints 84%

TSTF-425, Rev. 3 Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5b 84%

TSTF-511, Rev. 0 Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 2 83%

TSTF-510-A, Rev. 2 Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection 80%

TSTF-484, Rev. 0 Use of TS 3.10.1 for Scram Time Testing Activities. 79%

TSTF-426, Rev. 5 Revise or Add Actions to Preclude Entry into LCO 3.0.3 - RITSTF Initiatives 6b & 6c 71%

TSTF-421, Rev. 0 Revision to RCP Flywheel Inspection Program (WCAP-15666) 69%

TSTF-545, Rev. 3 TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing 69%

TSTF-523-A, Rev. 2 Generic Letter 2008-01, Managing Gas Accumulation 63%

TSTF-372, Rev. 4 Addition of LCO 3.0.8, Inoperability of Snubbers 60%

TSTF-370, Rev. 0 Increase accumulator Completion Time from 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (WCAP-15049) 60%

TSTF-522, Rev. 0 Revise Ventilation System Surveillance Requirements to Operate for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> per Month 59%

TSTF-490, Rev. 0 Deletion of E Bar Definition and Revision to RCS Specific Activity Tech Spec 58%

N/A Elimination of Typical License Condition Requiring Reporting of Violations of Section 2.C 56%

TSTF-476, Rev. 1 Improved BPWS Control Rod Insertion Process (NEDO-33091) 54%

TSTF-477, Rev. 3 Add Action for Two Inoperable Control Room AC Subsystems 50%

TSTF-423, Rev. 1 Technical Specifications End States, NEDC-32988-A 46%

TSTF-514, Rev. 3 Revise BWR Operability Requirements and Actions for RCS Leakage Instrumentation 46%

TSTF-374, Rev. 0 Revision to TS 5.5.13 and associated TS Bases for Diesel Fuel Oil 45%

TSTF-486, Rev. 2 Revise MTC Surveillance for Startup Test Activity Reduction (STAR) Program (WCAP-16011) 43%

TSTF-551, Rev. 3 Revise Secondary Containment Surveillance Requirements 42%

TSTF-513, Rev. 3 Revise PWR Operability Requirements and Actions for RCS Leakage Instrumentation 40%

TSTF-529, Rev. 4 Clarify Use and Application Rules 38%

TSTF-427, Rev. 2 Allowance for Non Technical Specification Barrier Degradation on Supported System OPERABIL 38%

TSTF-475, Rev. 1 Control Rod Notch Testing Frequency and SRM Insert Control Rod Action 38%

TSTF-491, Rev. 2 Removal of Main Steam and Main Feedwater Valve Isolation Times From Technical Specificatio 38%

TSTF-422, Rev. 2 Change in Technical Specifications End States (CE NPSD-1186) 29%

TSTF-487, Rev. 1 Relocate DNB Parameters to the COLR 29%

TSTF-501, Rev. 1 Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control 28%

TSTF-547, Rev. 1 Clarification of Rod Position Requirements 28%

TSTF-412, Rev. 3 Provide Actions for One Steam Supply to Turbine Driven AFW/EFW Pump Inoperable 26%

TSTF-430, Rev. 0 AOT Extension to 7 Days for LPI and Containment Spray (BAW-2295-A, Rev. 1) 25%

TSTF-431, Rev. 3 Change in Technical Specifications End States (BAW-2441) 25%

TSTF-432, Rev.1 Change in Technical Specifications End States (WCAP-16294) 21%

TSTF-500-A, Rev. 2 DC Electrical Rewrite - Update to TSTF-360 20%

TSTF-493, Rev. 4 Clarify Application of Setpoint Methodology for LSSS Functions 16%

TSTF-478, Rev. 2 BWR Technical Specification Changes that Implement the Revised Rule for Combustible Gas Co 13%

TSTF-505-A, Rev. 1 Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b 9%

TSTF-446, Rev. 3 Risk Informed Evaluation of Extensions to Containment Isolation Valve Completion Times (WCAP-15791) 7%

TSTF-546, Rev. 0 Revise APRM Channel Adjustment Surveillance Requirement 4%

TSTF-409, Rev. 2 Containment Spray System Completion Time Extension (CE NPSD-1045-A) 0%

TSTF-454, Rev. 1 Increase PCIV Completion Times from 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, and 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> to 7 days (NEDC-33046) 0%

TSTF-498, Rev. 1 Risk-Informed Containment Isolation Valve Completion Times (BAW-2461) 0%

Green Underline - Risk Informed Red Underline - NRC Initiated or Requirement

Examination of Traveler Review Time 2016-2018 160 approved LARs to adopt travelers Average review time (Submittal to Approval): 308 days (< 10 months)

Excluding Vogtle TSTF-505 review (1,565 days)

  • 35 (22%) review time over 1 year (Average 480 days, 15.8 months)
  • 16 (10%) review over 13 months (Average 525 days, 17.25 months)

Traveler Adoption Review Time > 13 months Plant Name TSTF Number Approval Submittal Review Date Date Time Hatch 1 & 2 TSTF-500-A, 08/29/17 08/11/15 749 Rev. 2 Cook 1 & 2 TSTF-490, Rev. 10/20/16 11/14/14 706 0

Perry TSTF-425, Rev. 02/23/16 03/25/14 700 3

Columbia TSTF-425, Rev. 11/02/16 03/17/15 596 3

Susquehanna 1 & 2 TSTF-425, Rev. 05/20/16 10/26/14 572 3

Columbia TSTF-423, Rev. 02/03/16 08/12/14 540 1

Brunswick 1 & 2 TSTF-425, Rev. 05/24/17 12/21/15 520 3

Fermi TSTF-545, Rev. 11/29/17 07/25/16 492 3

Cook 1 & 2 TSTF-425, Rev. 03/31/17 12/14/15 473 3

Harris TSTF-425, Rev. 11/29/16 08/18/15 469 3

Hatch 1 & 2 TSTF-523-A, 04/16/16 01/13/15 459 Rev. 2 Watts Bar Unit 2 TSTF-547, Rev. 02/13/18 11/23/16 447 1

Nine Mile Point 1 TSTF-425, Rev. 05/31/16 03/26/15 432 3

Farley 1 & 2 TSTF-432, 06/10/16 04/13/15 424 Rev.1 Surry 1 & 2 TSTF-523-A, 02/29/16 01/14/15 411 Rev. 2 Waterford 3 TSTF-425, Rev. 07/26/16 06/17/15 405 3

Page 1 EXCEL Services Corporation

Examination of Traveler Review Time 2016-2018 TSTF-425, 10 submittals, average of 493 days (16 months)

TSTF-425 Review Time vs. Approval Date 800 700 600 500 400 300 200 100 0

Examining the three TSTF-425 approvals in 2017:

  • Brunswick submitted 3 supplements and 5 RAI responses
  • D.C. Cook submitted 2 supplements and 4 RAI responses
  • Cooper had no supplements and one RAI response Page 2 EXCEL Services Corporation