{{#Wiki_filter:August 18, 2023
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION


==SUBJECT:==
==REGION I==
RNDT, INC. - NRC INSPECTION REPORT NO. 03038850/2023001 AND NOTICE OF VIOLATION
475 ALLENDALE ROAD, SUITE 102 KING OF PRUSSIA, PA 19406 -1415
 
August 18, 2023
 
Erik Korenoski, President RNDT, Inc.
 
228 Maple Avenue Johnstown, PA 15901-1424
 
SUBJECT: RNDT, INC. - NRC INSPECTION REPORT NO. 03038850/2023001 AND NOTICE OF VIOLATION


==Dear Eric Korenoski:==
==Dear Eric Korenoski:==
This letter refers to the inspection conducted on June 7, 2023, at your Johnstown, PA office and at a temporary job site located in Pennsboro, WV. The inspection was continued in-office until August 14, 2023. This inspection examined activities conducted under your license as they relate to public health and safety, and to confirm compliance with the Commissions rules and regulations and with the conditions of your license. Within these areas, the inspection consisted of selected examination of procedures and representative records, observations of activities, and interviews with personnel. We shared the results of the inspection with Brian Low of your staff during an inspection exit telephone call on August 14, 2023.
This letter refers to the inspection conducted on June 7, 2023, at your Johnstown, PA office and at a temporary job site located in Pennsboro, WV. The inspection was continued in-office until August 14, 2023. This inspection examined activities conducted under your license as they relate to public health and safety, and to confirm compliance with the Commission s rules and regulations and with the conditions of your license. Within these areas, the inspection consisted of selected examination of procedures and representative records, observations of activities, and interviews with personnel. We shared the results of the inspection with Brian Low of your staff during an inspection exit telephone call on August 14, 2023.


Based on the results of this inspection, the NRC has determined that one Severity Level IV violation of NRC requirements occurred. The violation was evaluated in accordance with the NRC Enforcement Policy. The current Enforcement Policy is included on the NRCs Web site at https://www.nrc.gov/about-nrc/regulatory/enforcement/enforce-pol.html. The violation is cited in the enclosed Notice of Violation (Notice) because the violation was identified by the NRC.
Based on the results of this inspection, the NRC has determined that one Severity Level IV violation of NRC requirements occurred. The violation was evaluated in accordance with the NRC Enforcement Policy. The current Enforcement Policy is included on the NRC s Web site at https://www.nrc.gov/about-nrc/regulatory/enforcement/enforce-pol.html. The violation is cited in the enclosed Notice of Violation (Notice) because the violation was identified by the NRC.


You are required to respond to this letter and should follow the instructions specified in the enclosed Notice when preparing your response. If you have additional information that you believe the NRC should consider, you may provide it in your response to the Notice. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction. The NRC review of your response to the Notice will also determine whether further enforcement action is necessary to ensure compliance with regulatory requirements.
You are required to respond to this letter and should follow the instructions specified in the enclosed Notice when preparing your response. If you have additional information that you believe the NRC should consider, you may provide it in your response to the Notice. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction. The NRC review of your response to the Notice will also determine whether further enforcement action is necessary to ensure compliance with regulatory requirements.


In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and your response will be made available electronically for public inspection in the NRC Public Document Room located at NRC Headquarters in Rockville, MD, and from the NRCs document system, the Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. However, the material enclosed herewith contains Security-Related Information as described above. Therefore, the material in the enclosures will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS). Similarly, your response will also be made publicly available electronically for public inspection in the NRC Public Document The enclosure(s) contains Sensitive Unclassified Non-Safeguards Information Upon separation, this cover letter is DECONTROLLED. Room or from the NRC document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html, unless it contains Security-Related Information.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and your response will be made available electronically for public inspection in the NRC Public Document Room located at NRC Headquarters in Rockville, MD, and from the NRCs document system, the Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. However, the material enclosed herewith contains Security-Related Information as described above. Therefore, the material in the enclosures will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS). Similarly, your response will also be made publicly available electronically for public inspection in the NRC Public Document
 
The enclosure(s) contains Sensitive Unclassified Non-Safeguards Information Upon separation, this cover letter is DECONTROLLED. Room or from the NRC document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html, unless it contains Security-Related Information.


If you have any questions regarding this matter, please contact Randolph Ragland of my staff at 610-337-5083 or via electronic mail at 610-337-5083.
If you have any questions regarding this matter, please contact Randolph Ragland of my staff at 610-337-5083 or via electronic mail at 610-337-5083.
Line 36: Line 46:
Thank you for your cooperation.
Thank you for your cooperation.


Sincerely, Digitally signed by Christopher Christopher G. Cahill Date: 2023.08.18 G. Cahill 11:47:51 -04'00'
Sincerely, Chris G. Cahill, Chief Commercial, Industrial, R&D and Academic Branch Division of Radiological Safety and Security Region I
Chris G. Cahill, Chief Commercial, Industrial, R&D and Academic Branch Division of Radiological Safety and Security Region I Docket No. 03038850 License No. 37-30942-02 Enclosure:
 
Non-public Notice of Violation cc with enclosure:
Docket No. 03038850 License No. 37 -30942- 02
 
Enclosure:
Non-public Notice of Violation
 
cc with enclosure:
1. Brian Low, Radiation Safety Officer 2. Commonwealth of Pennsylvania
1. Brian Low, Radiation Safety Officer 2. Commonwealth of Pennsylvania
}}
}}

Latest revision as of 13:52, 13 November 2024

(Cover Letter Only) Rndt, Inc. - NRC Inspection Report No. 03038850/2023001 and Notice of Violation
ML23229A501
Person / Time
Site: 05000202, 03038850
Issue date: 08/18/2023
From: Christopher Cahill
Decommissioning, ISFSI, and Reactor Health Physics Branch
To: Korenoski E
RNDT
References
IR 2023001
Download: ML23229A501 (1)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION I

475 ALLENDALE ROAD, SUITE 102 KING OF PRUSSIA, PA 19406 -1415

August 18, 2023

Erik Korenoski, President RNDT, Inc.

228 Maple Avenue Johnstown, PA 15901-1424

SUBJECT: RNDT, INC. - NRC INSPECTION REPORT NO. 03038850/2023001 AND NOTICE OF VIOLATION

Dear Eric Korenoski:

This letter refers to the inspection conducted on June 7, 2023, at your Johnstown, PA office and at a temporary job site located in Pennsboro, WV. The inspection was continued in-office until August 14, 2023. This inspection examined activities conducted under your license as they relate to public health and safety, and to confirm compliance with the Commission s rules and regulations and with the conditions of your license. Within these areas, the inspection consisted of selected examination of procedures and representative records, observations of activities, and interviews with personnel. We shared the results of the inspection with Brian Low of your staff during an inspection exit telephone call on August 14, 2023.

Based on the results of this inspection, the NRC has determined that one Severity Level IV violation of NRC requirements occurred. The violation was evaluated in accordance with the NRC Enforcement Policy. The current Enforcement Policy is included on the NRC s Web site at https://www.nrc.gov/about-nrc/regulatory/enforcement/enforce-pol.html. The violation is cited in the enclosed Notice of Violation (Notice) because the violation was identified by the NRC.

You are required to respond to this letter and should follow the instructions specified in the enclosed Notice when preparing your response. If you have additional information that you believe the NRC should consider, you may provide it in your response to the Notice. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction. The NRC review of your response to the Notice will also determine whether further enforcement action is necessary to ensure compliance with regulatory requirements.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and your response will be made available electronically for public inspection in the NRC Public Document Room located at NRC Headquarters in Rockville, MD, and from the NRCs document system, the Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. However, the material enclosed herewith contains Security-Related Information as described above. Therefore, the material in the enclosures will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS). Similarly, your response will also be made publicly available electronically for public inspection in the NRC Public Document

The enclosure(s) contains Sensitive Unclassified Non-Safeguards Information Upon separation, this cover letter is DECONTROLLED. Room or from the NRC document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html, unless it contains Security-Related Information.

If you have any questions regarding this matter, please contact Randolph Ragland of my staff at 610-337-5083 or via electronic mail at 610-337-5083.

Thank you for your cooperation.

Sincerely, Chris G. Cahill, Chief Commercial, Industrial, R&D and Academic Branch Division of Radiological Safety and Security Region I

Docket No. 03038850 License No. 37 -30942- 02

Enclosure:

Non-public Notice of Violation

cc with enclosure:

1. Brian Low, Radiation Safety Officer 2. Commonwealth of Pennsylvania