ML19350A311: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19350A312 | | number = ML19350A312 | ||
| issue date = 03/05/1981 | | issue date = 03/05/1981 | ||
| title = | | title = LER 81-008/03L-0:on 810203,control Area Ventilation Sys Train a Declared Inoperable.Caused by Draining Essential Header to Repair Leaking Valves in Nuclear Svc Water Sys. Valves Repaired & Train a Returned to Svc | ||
| author name = Ouellette R | | author name = Ouellette R | ||
| author affiliation = DUKE POWER CO. | | author affiliation = DUKE POWER CO. |
Latest revision as of 19:42, 16 January 2020
Date released: 12/30/2019 | Download: ML19350A311 |
---|---|
ML19350A312 | |
Person / Time | |
---|---|
Site: | McGuire |
Issue date: | 03/05/1981 |
From: | Ouellette R DUKE POWER CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19350A312 (1) | |
ML19350A310 | |
Person / Time | |
---|---|
Site: | McGuire |
Issue date: | 03/05/1981 |
From: | Parker W DUKE POWER CO. |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |