{{#Wiki_filter:OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION April 3, 2018  
{{#Wiki_filter:OFFICIAL USE ONLY - PROPRIETARY INFORMATION April 3, 2018 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066
 
Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066  


==SUBJECT:==
==SUBJECT:==
DRAFT SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-18124-NP, REVISION 0, "FLUENCE DETERMINATION WITH RAPTOR-M3G AND FERRET" (CAC NO. MF9141)  
DRAFT SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-18124-NP, REVISION 0, FLUENCE DETERMINATION WITH RAPTOR-M3G AND FERRET (CAC NO. MF9141)


==Dear Mr. Gresham:==
==Dear Mr. Gresham:==


By letter dated January 25, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17030A377), Westinghouse Electric Company (Westinghouse) submitted for U. S. Nuclear Regulatory Commission (NRC) staff review Topical Report (TR)
By letter dated January 25, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17030A377), Westinghouse Electric Company (Westinghouse) submitted for U. S. Nuclear Regulatory Commission (NRC) staff review Topical Report (TR)
WCAP-18124-NP, Revision 0, "Fluence Determination with RAPTOR-M3G and FERRET." By letter dated November 21, 2017 (ADAMS Accession No. ML17290A147), the NRC staff issued the requests for additional information for the review of TR WCAP-18124-NP, Revision 0.
WCAP-18124-NP, Revision 0, "Fluence Determination with RAPTOR-M3G and FERRET." By letter dated November 21, 2017 (ADAMS Accession No. ML17290A147), the NRC staff issued the requests for additional information for the review of TR WCAP-18124-NP, Revision 0.
Enclosed for Westinghouse review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR WCAP-18124-NP, Revision 0.  
Enclosed for Westinghouse review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR WCAP-18124-NP, Revision 0.
 
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for you to comment on the proprietary aspects and provide any factual errors or clarity concerns contained in the SE. The final SE will be issued after making any necessary changes and a non-proprietary version will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for you to comment on the proprietary aspects and provide any factual errors or clarity concerns contained in the SE. The final SE will be issued after making any necessary changes and a non-proprietary version will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.  
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
 
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.


OFFICIAL USE ONLY - PROPRIETARY INFORMATION J. Gresham                                      To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact Ekaterina Lenning at 301-415-3151.
If you have any questions, please contact Ekaterina Lenning at 301-415-3151.
Sincerely,         /RA/
Sincerely,
 
                                                    /RA/
Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation  
Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation


==Enclosure:==
==Enclosure:==


Draft SE (Proprietary)  
Draft SE (Proprietary)
OFFICIAL USE ONLY - PROPRIETARY INFORMATION


Pkg.: ML18057A067; Letter: ML18057A034; Enclosure (PROP): ML18057A056; *via e-mail     NRR-106 OFFICE NRR/DLP/PLPB/PM* NRR/DLP/PLPB/LA* NRR/DSS/STSB/BC* NAME ELenning DHarrison VCusumano DATE 3/29/18 3/20/18 3/29/18 OFFICE NRR/DSS/SNPB/BC* NRR/DLP/PLPB/BC NAME SAnderson DMorey DATE 3/29/18 4/3/18}}
Pkg.: ML18057A067; Letter: ML18057A034; Enclosure (PROP): ML18057A056; *via e-mail                         NRR-106 OFFICE NRR/DLP/PLPB/PM*           NRR/DLP/PLPB/LA*       NRR/DSS/STSB/BC*
NAME     ELenning               DHarrison             VCusumano DATE     3/29/18                 3/20/18               3/29/18 OFFICE NRR/DSS/SNPB/BC*           NRR/DLP/PLPB/BC NAME     SAnderson               DMorey DATE     3/29/18                 4/3/18}}

Latest revision as of 18:31, 21 October 2019

Cover Letter for Draft Safety Evaluation for Westinghouse Electric Company (Westinghouse) Topical Report WCAP-18124-NP, Revision 0, Fluence Determination with Raptor-M3G and Ferret
ML18057B034
Person / Time
Issue date: 04/03/2018
From: Dennis Morey
NRC/NRR/DLP/PLPB
To: Gresham J
Westinghouse
Lenning E
Shared Package
ML18057A067 List:
References
CAC MF9141, WCAP-18124-NP, Rev 0
Download: ML18057B034 (3)


Text

OFFICIAL USE ONLY - PROPRIETARY INFORMATION April 3, 2018 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066

SUBJECT:

DRAFT SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC COMPANY TOPICAL REPORT WCAP-18124-NP, REVISION 0, FLUENCE DETERMINATION WITH RAPTOR-M3G AND FERRET (CAC NO. MF9141)

Dear Mr. Gresham:

By letter dated January 25, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17030A377), Westinghouse Electric Company (Westinghouse) submitted for U. S. Nuclear Regulatory Commission (NRC) staff review Topical Report (TR)

WCAP-18124-NP, Revision 0, "Fluence Determination with RAPTOR-M3G and FERRET." By letter dated November 21, 2017 (ADAMS Accession No. ML17290A147), the NRC staff issued the requests for additional information for the review of TR WCAP-18124-NP, Revision 0.

Enclosed for Westinghouse review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR WCAP-18124-NP, Revision 0.

Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for you to comment on the proprietary aspects and provide any factual errors or clarity concerns contained in the SE. The final SE will be issued after making any necessary changes and a non-proprietary version will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.

OFFICIAL USE ONLY - PROPRIETARY INFORMATION

OFFICIAL USE ONLY - PROPRIETARY INFORMATION J. Gresham To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.

If you have any questions, please contact Ekaterina Lenning at 301-415-3151.

Sincerely,

/RA/

Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation

Enclosure:

Draft SE (Proprietary)

OFFICIAL USE ONLY - PROPRIETARY INFORMATION

Pkg.: ML18057A067; Letter: ML18057A034; Enclosure (PROP): ML18057A056; *via e-mail NRR-106 OFFICE NRR/DLP/PLPB/PM* NRR/DLP/PLPB/LA* NRR/DSS/STSB/BC*

NAME ELenning DHarrison VCusumano DATE 3/29/18 3/20/18 3/29/18 OFFICE NRR/DSS/SNPB/BC* NRR/DLP/PLPB/BC NAME SAnderson DMorey DATE 3/29/18 4/3/18