ML091910434: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| issue date = 07/10/2009
| issue date = 07/10/2009
| title = Notification of Inspection (NRC Inspection Report 05000482-09-005  and Request for Information
| title = Notification of Inspection (NRC Inspection Report 05000482-09-005  and Request for Information
| author name = Farnholtz T R
| author name = Farnholtz T
| author affiliation = NRC/RGN-IV/DRS/EB-1
| author affiliation = NRC/RGN-IV/DRS/EB-1
| addressee name = Muench R A
| addressee name = Muench R
| addressee affiliation = Wolf Creek Nuclear Operating Corp
| addressee affiliation = Wolf Creek Nuclear Operating Corp
| docket = 05000482
| docket = 05000482
Line 14: Line 14:
| page count = 12
| page count = 12
}}
}}
See also: [[followed by::IR 05000482/2009005]]
See also: [[see also::IR 05000482/2009005]]


=Text=
=Text=
{{#Wiki_filter:UNITED STATESNUCLEAR REGULATORY COMMISSIONREGION IV612 EAST LAMAR BLVD, SUITE 400ARLINGTON, TEXAS 76011-4125July 10, 2009  
{{#Wiki_filter:UNITED STATES
  Rick A. Muench, President and   Chief Executive Officer  
                                NUC LE AR RE G UL AT O RY C O M M I S S I O N
Wolf Creek Nuclear Operating Corporation P.O. Box 411 Burlington, KS 66839  
                                                    R E GI ON I V
SUBJECT: WOLF CREEK GENERATING STATION - NOTIFICATION OF INSPECTION (NRC INSPECTION REPORT 05000482/2009005 ) AND REQUEST FOR INFORMATION  
                                        612 EAST LAMAR BLVD , SU I TE 400
Dear Mr. Muench, From October 15 through October 30, 2009, reactor inspectors from the Nuclear Regulatory Commission's (NRC) Region IV office will perform the baseline inservice inspection at the Wolf  
                                        AR LI N GTON , TEXAS 76011-4125
Creek Generating Station, using NRC Inspection Procedure 71111.08, "Inservice Inspection Activities," and TI 2515/172, "Reactor Coolant System Dissimilar Metal Butt Welds." Experience has shown that this inspection is a resource intensive inspection both for the NRC inspectors and your staff. In order to minimize the impact to your onsite resources and to ensure a productive inspection, we have enclosed a request for documents needed for this inspection.
                                              July 10, 2009
These documents have been divided into two groups. The first group (Section A of the enclosure) identified information to be provided prior to the inspection to ensure that the inspectors are adequately prepared. The second group (Section B of the enclosure) identifies the information the inspectors will need upon arrival at the site. It is important that all of these documents are up to date and complete in order to minimize the number of additional  
Rick A. Muench, President and
documents requested during the preparation and/or the onsite portions of the inspection.  
  Chief Executive Officer
We have discussed the schedule for these inspection activities with your staff and understand that our regulatory contact for this inspection will be Mr. William Muilenberg, of your licensing organization. Our inspection dates are subject to change based on your updated schedule of  
Wolf Creek Nuclear Operating Corporation
outage activities. If there are any questions about this inspection or the material requested, please contact the lead inspector Ronald A. Kopriva, at (817) 860-8104, or ron.kopriva@nrc.gov. In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document  
P.O. Box 411
system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Burlington, KS 66839
Wolf Creek Nuclear Operating Corporation - 2 -
SUBJECT:       WOLF CREEK GENERATING STATION - NOTIFICATION OF INSPECTION
  Sincerely,  /RA/
                (NRC INSPECTION REPORT 05000482/2009005 ) AND REQUEST FOR
  Thomas Farnholtz, Chief  Engineering Branch 1  Division of Reactor Safety
                INFORMATION
Dear Mr. Muench,
Docket:  50-482 License:  NPF-42 
From October 15 through October 30, 2009, reactor inspectors from the Nuclear Regulatory
Enclosure: Inservice Inspection Document Request
Commissions (NRC) Region IV office will perform the baseline inservice inspection at the Wolf
Vice President Operations/Plant Manager
Creek Generating Station, using NRC Inspection Procedure 71111.08, "Inservice Inspection
Wolf Creek Nuclear Operating Corporation P.O. Box 411 Burlington, KS  66839
Activities," and TI 2515/172, "Reactor Coolant System Dissimilar Metal Butt Welds." Experience
Jay Silberg, Esq.
has shown that this inspection is a resource intensive inspection both for the NRC inspectors
Pillsbury Winthrop Shaw Pittman LLP 2300 N Street, NW Washington, DC  20037
and your staff. In order to minimize the impact to your onsite resources and to ensure a
Supervisor Licensing
productive inspection, we have enclosed a request for documents needed for this inspection.
Wolf Creek Nuclear Operating Corporation P.O. Box 411 Burlington, KS  66839
These documents have been divided into two groups. The first group (Section A of the
Chief Engineer
enclosure) identified information to be provided prior to the inspection to ensure that the
Utilities Division Kansas Corporation Commission 1500 SW Arrowhead Road Topeka, KS  66604-4027
inspectors are adequately prepared. The second group (Section B of the enclosure) identifies
the information the inspectors will need upon arrival at the site. It is important that all of these
Office of the Governor State of Kansas Topeka, KS  66612-1590
documents are up to date and complete in order to minimize the number of additional
Attorney General 120 S.W. 10th Avenue, 2nd Floor Topeka, KS  66612-1597
documents requested during the preparation and/or the onsite portions of the inspection.
We have discussed the schedule for these inspection activities with your staff and understand
that our regulatory contact for this inspection will be Mr. William Muilenberg, of your licensing
organization. Our inspection dates are subject to change based on your updated schedule of
outage activities. If there are any questions about this inspection or the material requested,
please contact the lead inspector Ronald A. Kopriva, at (817) 860-8104, or
ron.kopriva@nrc.gov.
In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice," a copy of this letter and its
enclosure will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records (PARS) component of NRCs document
system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-
rm/adams.html (the Public Electronic Reading Room).


County Clerk Coffey County Courthouse 110 South 6th Street Burlington, KS 66839  
Wolf Creek Nuclear Operating Corporation -2-
                                        Sincerely,
                                            /RA/
                                        Thomas Farnholtz, Chief
                                        Engineering Branch 1
                                        Division of Reactor Safety
Docket: 50-482
License: NPF-42
Enclosure:
Inservice Inspection Document Request
Vice President Operations/Plant Manager
Wolf Creek Nuclear Operating Corporation
P.O. Box 411
Burlington, KS 66839
Jay Silberg, Esq.
Pillsbury Winthrop Shaw Pittman LLP
2300 N Street, NW
Washington, DC 20037
Supervisor Licensing
Wolf Creek Nuclear Operating Corporation
P.O. Box 411
Burlington, KS 66839
Chief Engineer
Utilities Division
Kansas Corporation Commission
1500 SW Arrowhead Road
Topeka, KS 66604-4027
Office of the Governor
State of Kansas
Topeka, KS 66612-1590
Attorney General
120 S.W. 10th Avenue, 2nd Floor
Topeka, KS 66612-1597
County Clerk
Coffey County Courthouse
110 South 6th Street
Burlington, KS 66839


 
Wolf Creek Nuclear Operating Corporation -3-
Wolf Creek Nuclear Operating Corporation - 3 -  
Chief, Radiation and Asbestos
Chief, Radiation and Asbestos   Control Section Bureau of Air and Radiation Kansas Department of Health and  
Control Section
  Environment 1000 SW Jackson, Suite 310 Topeka, KS 66612-1366  
Bureau of Air and Radiation
Chief, Technological Hazards  
Kansas Department of Health and
  Branch FEMA, Region VII 9221 Ward Parkway Suite 300 Kansas City, MO 64114-3372
Environment
Wolf Creek Nuclear Operating Corporation - 4 -  
1000 SW Jackson, Suite 310
Electronic distribution by RIV: Regional Administrator (Elmo.Collins@nrc.gov ) Deputy Regional Administrator (Chuck.Casto@nrc.gov ) DRP Director (Dwight.Chamberlain@nrc.gov ) DRP Deputy Director (Anton.Vegel@nrc.gov ) DRS Director (Roy.Caniano@nrc.gov ) DRS Deputy Director (Troy.Pruett@nrc.gov ) Senior Resident Inspector (Chris.Long@nrc.gov ) Resident Inspector (Charles.Peabody@nrc.gov ) Site Secretary (Shirley.Allen@nrc.gov ) Branch Chief, DRP/B (Vincent.Gaddy@nrc.gov ) Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov ) Public Affairs Officer (Victor.Dricks@nrc.gov ) Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov ) RITS Coordinator (Marisa.Herrera@nrc.gov ) Regional Counsel (Karla.Fuller@nrc.gov ) Congressional Affairs Officer (Jenny.Weil@nrc.gov ) OEMail Resource  
Topeka, KS 66612-1366
 
Chief, Technological Hazards
   
  Branch
   
FEMA, Region VII
   
9221 Ward Parkway
SUNSI Review Completed: ___Y___ ADAMS:   Yes  No        Initials: ___TRF
Suite 300
_    Publicly Available         Non-Publicly Available         Sensitive   Non-Sensitive S:\DRS\REPORTS\WC 2009005 RFI -RAK     ML091910434
Kansas City, MO 64114-3372
SRI:EB1 C:EB1   RAKopriva TFarnholtz   /RA/ /RA/   7/8/09 7/10/09   OFFICIAL RECORD COPY T=Telephone           E=E-mail       F=Fax
 
 
Wolf Creek Nuclear Operating Corporation           -4-
  - 1 - Enclosure INSERVICE INSPECTION DOCUMENT REQUEST  
Electronic distribution by RIV:
  Inspection Dates: October 15 through October 30, 2009  
Regional Administrator (Elmo.Collins@nrc.gov )
Inspection Procedures: IP 71111.08 "Inservice Inspection (ISI) Activities" TI 2515/172 "Reactor Coolant System Dissimilar Metal Butt Welds" Inspectors: Ronald A. Kopriva, Senior Reactor Inspector (Lead Inspector - ISI) James Drake, Senior Reactor Inspector  
Deputy Regional Administrator (Chuck.Casto@nrc.gov )
DRP Director (Dwight.Chamberlain@nrc.gov )
A. Information Requested for the In-Office Preparation Week  
DRP Deputy Director (Anton.Vegel@nrc.gov )
The following information should be sent to the Region IV office in hard copy or electronic format (ims.certrec.com preferred), in care of Ronald A. Kopriva, by September 28, 2009, to facilitate the selection of specific items that will be reviewed during the onsite inspection week. The inspector will select specific items from the information requested below and then request from your staff additional documents  
DRS Director (Roy.Caniano@nrc.gov )
needed during the onsite inspection week (Section B of this enclosure). We ask that the specific items selected from the lists be available and ready for review on the first day of inspection. *Please provide requested documentation electronically if possible. If requested documents are large and only hard copy formats are available, please inform the inspector(s), and provide subject documentation during the first day of the onsite inspection. If you have any questions regarding this information request, please call the inspector as soon as possible.  
DRS Deputy Director (Troy.Pruett@nrc.gov )
A.1 ISI/Welding Programs and Schedule Information
Senior Resident Inspector (Chris.Long@nrc.gov )
  a) A detailed schedule (including preliminary dates) of:  
Resident Inspector (Charles.Peabody@nrc.gov )
i) Nondestructive examinations (NDEs) planned for Class 1 & 2 systems and containment, performed as part of your ASME Section XI, Risk Informed (if applicable), and augmented ISI programs during the  
Site Secretary (Shirley.Allen@nrc.gov )
upcoming outage.  
Branch Chief, DRP/B (Vincent.Gaddy@nrc.gov )
Provide a status summary of the NDE inspection activities vs. the required inspection period percentages for this Interval by category per ASME Section XI, IWX-2400 (Do not provide separately if other  
Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov )
documentation requested contains this information)  
Public Affairs Officer (Victor.Dricks@nrc.gov )
ii) Reactor pressure vessel head (RPVH) examinations planned for the upcoming outage.  
Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov )
iii) Examinations planned for Alloy 82/182/600 components that are not included in the Section XI scope. (If applicable)  
RITS Coordinator (Marisa.Herrera@nrc.gov )
iv) Examinations planned as part of your Boric Acid Corrosion Control Program (Mode 3 walkdowns, bolted connection walkdowns, etc.)  
Regional Counsel (Karla.Fuller@nrc.gov )
 
Congressional Affairs Officer (Jenny.Weil@nrc.gov )
  - 2 - Enclosure v) Welding activities that are scheduled to be completed during the upcoming outage (ASME Class 1, 2, or 3 structures, systems, or components (SSCs))  
OEMail Resource
b) A copy of ASME Section XI Code Relief Requests and associated NRC Safety Evaluations applicable to the examinations identified above.
SUNSI Review Completed: ___Y___             ADAMS: 7 Yes         No   Initials: ___TRF_
  c) A list of NDE reports (ultrasonic, radiography, magnetic particle, dye penetrate, Visual VT-1, VT-2, and VT-3), which have identified relevant conditions on Code Class 1 & 2 systems since the beginning of the last refueling outage. This should include the previous Section XI pressure test(s) conducted during start up and  
7 Publicly Available       Non-Publicly Available     Sensitive     7 Non-Sensitive
any evaluations associated with the results of the pressure tests. Also, include in the list the NDE reports with relevant conditions in the RPVH penetration nozzles which have been accepted for continued service. The list of NDE reports should include a brief description of the SSC where the relevant condition was identified.  
S:\DRS\REPORTS\WC 2009005 RFI -RAK                                     ML091910434
d) A list with a brief description (e.g., system, material, pipe size, weld number, and NDE performed) of the welds in Code Class 1 and 2 systems which have been  
SRI:EB1               C:EB1
fabricated due to component repair/replacement activities since the beginning of the last refueling outage, or are planned to be fabricated this refueling outage.  
RAKopriva             TFarnholtz
e) If reactor vessel weld examinations required by the ASME Code are scheduled to occur during the upcoming outage, provide a detailed description of the welds to  
/RA/                 /RA/
be examined and the extent of the planned examination. Please also provide reference numbers for applicable procedures that will be used to conduct these examinations.  
7/8/09               7/10/09
f) Copy of any 10 CFR Part 21 reports applicable to your SSCs within the scope of Section XI of the ASME Code that have been identified since the beginning of the last refueling outage.  
OFFICIAL RECORD COPY T=Telephone                 E=E-mail     F=Fax
g) A list of any temporary non-code repairs in service (e.g., pinhole leaks).  
 
h) Please provide copies of the most recent self assessments for the ISI, Welding, and Alloy 600 Programs.
                      INSERVICE INSPECTION DOCUMENT REQUEST
A.2 Reactor Pressure Vessel Head (RPVH)
Inspection Dates:         October 15 through October 30, 2009
  a) Provide the detailed scope of the planned NDE of the reactor vessel head which identifies the types of NDE methods to be used on each specific part of the vessel head to fulfill commitments made in response to NRC Bulletin 2002-02 and NRC Order EA-03-009. Also, include examination scope expansion criteria and planned expansion sample sizes if relevant conditions are identified. (If applicable)  
Inspection Procedures:     IP 71111.08 "Inservice Inspection (ISI) Activities"
b) A list of the standards and/or requirements that will be used to evaluate indications identified during NDE of the reactor vessel head (e.g., the specific industry or procedural standards which will be used to evaluate potential leakage and/or flaw indications).  
                          TI 2515/172 "Reactor Coolant System Dissimilar Metal Butt Welds"
 
Inspectors:               Ronald A. Kopriva, Senior Reactor Inspector (Lead Inspector - ISI)
  - 3 - Enclosure A.3 Boric Acid Corrosion Control Program (BACCP)
                          James Drake, Senior Reactor Inspector
  a) Copy of the procedures that govern the scope, equipment and implementation of the inspections required to identify boric acid leakage and the procedures for boric acid leakage/corrosion evaluation.  
A.     Information Requested for the In-Office Preparation Week
b) Please provide a list of leaks (including Code class of the components) that have been identified since the last refueling outage and associated corrective action documentation. If during the last cycle, the Unit was shutdown, please provide documentation of containment walkdown inspections performed as part of the BACCP. c) Please provide a copy of the most recent self-assessment performed for the BACCP. A.4 Steam Generator Tube (SGT) Inspections
      The following information should be sent to the Region IV office in hard copy or
  a) A detailed schedule of:  
      electronic format (ims.certrec.com preferred), in care of Ronald A. Kopriva, by
i) SGT inspection, data analyses, and repair activities for the upcoming outage. (If occurring)  
      September 28, 2009, to facilitate the selection of specific items that will be reviewed
ii) SG secondary side inspection activities for the upcoming outage. (If occurring)  
      during the onsite inspection week. The inspector will select specific items from the
b) Please provide a copy of your SG ISI Inspection Program and Plan. Please include a copy of the Operational Assessment from last outage and a copy of the following documents as they become available:
      information requested below and then request from your staff additional documents
i) Degradation Assessment ii) Condition Monitoring Assessment  
      needed during the onsite inspection week (Section B of this enclosure). We ask that the
c) If you are planning on modifying your Technical Specifications such that they are consistent with TSTF-449, please provide copies of your correspondence with the NRC regarding deviations from the STS.  
      specific items selected from the lists be available and ready for review on the first day of
d) Copy of SG history documentation given to vendors performing eddy current (ET) testing of the SGs during the upcoming outage.  
      inspection. *Please provide requested documentation electronically if possible. If
e) Copy of SG Eddy Current Data Analyst Guidelines and Site Validated Eddy Current Technique Specification Sheets (ETSS). Additionally, please provide a copy of EPRI Appendix H ETSS Qualification Records.  
      requested documents are large and only hard copy formats are available, please inform
f) Identify and quantify any SGT leakage experienced during the previous operating cycle. Also provide documentation identifying which SG was leaking and  
      the inspector(s), and provide subject documentation during the first day of the onsite
corrective actions completed or planned for this condition. (If applicable)  
      inspection. If you have any questions regarding this information request, please call the
g) Provide past history of the condition and issues pertaining to the secondary side of the steam generators (including items such as loose parts, fouling, top of tube sheet condition, crud removal amounts, etc.).
      inspector as soon as possible.
  - 4 - Enclosure  
A.1   ISI/Welding Programs and Schedule Information
h) Please provide copies of your most recent self assessments of the SG monitoring, loose parts monitoring, and secondary side water chemistry control programs.  
      a)     A detailed schedule (including preliminary dates) of:
i) Please also indicate where the primary, secondary, and resolution analyses are scheduled to take place.  
              i)     Nondestructive examinations (NDEs) planned for Class 1 & 2 systems
j) Please provide a summary of the scope of the SGT examinations, including examination methods such as Bobbin, Rotating Pancake, or Plus Point, and the percentage of tubes to be examined. *Do not provide these documents separately if already included in other information requested.   A.5 Materials Reliability (MRP-139) Program Activities
                      and containment, performed as part of your ASME Section XI, Risk
  a) A list of, with verification, that the baseline inspections of all applicable Dissimilar Metal Butt Welds (DMBWs) have been completed by September 28, 2009.  
                      Informed (if applicable), and augmented ISI programs during the
b) Verification that baseline inspection of hot leg and cold leg temperature DMBWs have been included in the inspection program and that the schedules for the baseline inspections are consistent with the baseline schedules in MRP-139.  
                      upcoming outage.
c) A list and schedule (examination dates) of all DMBW examinations planned for the upcoming refueling outage. If none are scheduled, then data from previous examinations should be available for review.  
                      Provide a status summary of the NDE inspection activities vs. the
d) A list and schedule for any welding to be performed on DMBWs in the upcoming outage. If no welding will be performed then records of previous welding on  
                      required inspection period percentages for this Interval by category per
DMBWs and postweld NDE documentation.  
                      ASME Section XI, IWX-2400 (Do not provide separately if other
e) A list and schedule of any stress improvement (SI) activities planned for the upcoming refueling outage. If none are scheduled then have qualification reports for any SIs previously performed.  
                      documentation requested contains this information)
f) Documentation and description of how the baseline and inservice inspection specifications in MRP-139 are satisfied at your facility.  
              ii)     Reactor pressure vessel head (RPVH) examinations planned for the
g) A list of weld locations controlled by MRP-139 which includes the MRP-139 weld category, pre-mitigation volumetric examination date, type of mitigation or stress improvement, post mitigation volumetric examination date, and plans for future MRP-139 required examinations.  
                      upcoming outage.
A.6 Additional information related to all ISI activities
              iii)   Examinations planned for Alloy 82/182/600 components that are not
  a) A list with a brief description of ISI, BACCP, and SGT inspection related issues (e.g., condition reports) entered into your corrective action program since the beginning of the last refueling outage. For example, a list based upon data base searches using key words related to piping or SG tube degradation such as: ISI, ASME Code, Section XI, NDE, cracks, wear, thinning, leakage, rust, corrosion, boric acid, or errors in piping/SGT examinations.
                      included in the Section XI scope. (If applicable)
  - 5 - Enclosure  
              iv)     Examinations planned as part of your Boric Acid Corrosion Control
b) Please provide names and phone numbers for the following program leads:  
                      Program (Mode 3 walkdowns, bolted connection walkdowns, etc.)
ISI contacts (Examination, planning) Containment Exams RPVH Exams  
                                            -1-                                         Enclosure
Snubbers and Supports Repair and Replacement Program Manager Licensing Contact Site Welding Engineer Boric Acid Corrosion Control Program  
 
SG Inspection Activities (site lead and vendor contact)  
          v)       Welding activities that are scheduled to be completed during the
B. Information to be provided onsite to the inspector(s) at the entrance meeting (October 16, 2009):  
                  upcoming outage (ASME Class 1, 2, or 3 structures, systems, or
B.1 ISI / Welding Programs and Schedule Information
                  components (SSCs))
  a) Updated schedules for ISI/NDE activities, including SGT inspections, planned welding activities, and schedule showing contingency repair plans, if available.  
    b)   A copy of ASME Section XI Code Relief Requests and associated NRC Safety
b) For ASME Code Class 1 and 2 welds selected by the inspector from the lists provided from section A of this enclosure, please provide copies of the following  
          Evaluations applicable to the examinations identified above.
documentation for each subject weld:  
    c)   A list of NDE reports (ultrasonic, radiography, magnetic particle, dye penetrate,
i) Weld data sheet (traveler) ii) Weld configuration and system location iii) Applicable Code Edition and Addenda for weldment  
          Visual VT-1, VT-2, and VT-3), which have identified relevant conditions on Code
iv) Applicable Code Edition and Addenda for welding procedures v) Applicable weld procedures (WPS) used to fabricate the welds vi) Copies of procedure qualification records (PQRs) supporting the WPS from B.1.b.v vii) Copies of mechanical test reports identified in the PQRs above  
          Class 1 & 2 systems since the beginning of the last refueling outage. This should
viii) Copies of the nonconformance reports for the selected welds (If applicable) ix) Radiographs of the selected welds and access to equipment to allow viewing radiographs (If RT was performed) x) Copies of the preservice examination records for the selected welds  
          include the previous Section XI pressure test(s) conducted during start up and
xi) Copies of welder performance qualifications records applicable to the selected welds, including documentation that welder maintained proficiency in the applicable welding processes specified in the WPS (at least six months prior to the date of subject work) xii) Copies of NDE personnel qualifications (VT, PT, UT, RT), as applicable  
          any evaluations associated with the results of the pressure tests. Also, include in
c) For the ISI related corrective action issues selected by the inspector(s) from section A of this enclosure, provide a copy of the corrective actions and supporting documentation.  
          the list the NDE reports with relevant conditions in the RPVH penetration nozzles
d) For the NDE reports with relevant conditions on Code Class 1 & 2 systems selected by the inspector from section A above, provide a copy of the
          which have been accepted for continued service. The list of NDE reports should
  - 6 - Enclosure examination records, examiner qualification records, and associated corrective action documents.  
          include a brief description of the SSC where the relevant condition was identified.
e) A copy of (or ready access to) most current revision of the ISI Program Manual and Plan for the current Interval.
    d)   A list with a brief description (e.g., system, material, pipe size, weld number, and
f) For the NDEs selected by the inspector from section A of this enclosure, provide copy of the NDE procedures used to perform the examinations (including calibration and flaw characterization/sizing procedures). For ultrasonic examination procedures qualified in accordance with ASME Code, Section XI, Appendix VIII, provide documentation supporting the procedure qualification (e.g., the EPRI performance demonstration qualification summary sheets). Also, include qualification documentation of the specific equipment to be used (e.g., ultrasonic unit, cables, and transducers including serial numbers) and NDE personnel qualification records.  
          NDE performed) of the welds in Code Class 1 and 2 systems which have been
B.2 Reactor Pressure Vessel Head (RPVH)
          fabricated due to component repair/replacement activities since the beginning of
  a) Provide the NDE personnel qualification records for the examiners who will perform examinations of the RPVH.
          the last refueling outage, or are planned to be fabricated this refueling outage.
b) Provide drawings showing the following: (If a visual examination is planned for the upcoming refueling outage).  
    e)   If reactor vessel weld examinations required by the ASME Code are scheduled to
i) RPVH and CRDM nozzle configurations ii) RPVH insulation configuration
          occur during the upcoming outage, provide a detailed description of the welds to
The drawings listed above should include fabrication drawings for the nozzle attachment  
          be examined and the extent of the planned examination. Please also provide
welds as applicable.
          reference numbers for applicable procedures that will be used to conduct these
c) Copy of NDE reports from the last RPVH examination.  
          examinations.
d) Copy of evaluation or calculation demonstrating that the scope of the visual examination of the upper head will meet the 95 percent minimum coverage required by NRC Order EA-03-009 (If a visual examination is planned for the upcoming refueling outage).  
    f)   Copy of any 10 CFR Part 21 reports applicable to your SSCs within the scope of
e) Provide a copy of the procedures that will be used to identify the source of any boric acid deposits identified on the RPVH. If no explicit procedures exist which govern this activity, provide a description of the process to be followed including personnel responsibilities and expectations.
          Section XI of the ASME Code that have been identified since the beginning of the
f) Provide a copy of the updated calculation of effective degradation years (EDY) for the RPVH susceptibility ranking.  
          last refueling outage.
    g)   A list of any temporary non-code repairs in service (e.g., pinhole leaks).
g) Provide copy of the vendor qualification report(s) that demonstrates the detection capability of the NDE equipment used for the RPVH examinations. Also, identify any changes in equipment configurations used for the RPVH examinations which differ from that used in the vendor qualification report(s).  
    h)   Please provide copies of the most recent self assessments for the ISI, Welding,
 
          and Alloy 600 Programs.
  - 7 - Enclosure B.3 Boric Acid Corrosion Control Program (BACCP)
A.2 Reactor Pressure Vessel Head (RPVH)
  a) Please provide boric acid walkdown inspection results, an updated list of boric acid leaks identified so far this outage, associated corrective action documentation, and overall status of planned boric acid inspections.  
    a)   Provide the detailed scope of the planned NDE of the reactor vessel head which
          identifies the types of NDE methods to be used on each specific part of the
b) Please provide any engineering evaluations completed for boric acid leaks identified since the end of the last refueling outage. Please include a status of corrective actions to repair and/or clean these boric acid leaks. Please identify specifically which known leaks, if any, have remained in service or will remain in service as active leaks.
          vessel head to fulfill commitments made in response to NRC Bulletin 2002-02
B.4 Steam Generator Tube (SGT) Inspections
          and NRC Order EA-03-009. Also, include examination scope expansion criteria
  a) Copies of the Examination Technique Specification Sheets (ETSS) and associated justification for any revisions.  
          and planned expansion sample sizes if relevant conditions are identified. (If
b) Copy of the guidance to be followed if a loose part or foreign material is identified in the SGs.  
          applicable)
c) Please provide a copy of the ET procedures used to perform the SGT inspections (specifically calibration and flaw characterization/sizing procedures, etc.). Also include documentation for the specific equipment to be used.  
    b)   A list of the standards and/or requirements that will be used to evaluate
d) Please provide copies of your responses to NRC and industry operating experience communications such as Generic Letters, Information Notices, etc. (as applicable to SGT inspections) *Do not provide these documents separately if already included in other information requested such as the degradation  
          indications identified during NDE of the reactor vessel head (e.g., the specific
assessment.  
          industry or procedural standards which will be used to evaluate potential leakage
e) List of corrective action documents generated by the vendor and/or site with respect to SG inspection activities.  
          and/or flaw indications).
 
                                        -2-                                       Enclosure
 
A.3 Boric Acid Corrosion Control Program (BACCP)
    a)     Copy of the procedures that govern the scope, equipment and implementation of
          the inspections required to identify boric acid leakage and the procedures for
          boric acid leakage/corrosion evaluation.
    b)     Please provide a list of leaks (including Code class of the components) that have
          been identified since the last refueling outage and associated corrective action
          documentation. If during the last cycle, the Unit was shutdown, please provide
          documentation of containment walkdown inspections performed as part of the
          BACCP.
    c)     Please provide a copy of the most recent self-assessment performed for the
          BACCP.
A.4 Steam Generator Tube (SGT) Inspections
    a)     A detailed schedule of:
          i)     SGT inspection, data analyses, and repair activities for the upcoming
                  outage. (If occurring)
          ii)     SG secondary side inspection activities for the upcoming outage. (If
                  occurring)
    b)     Please provide a copy of your SG ISI Inspection Program and Plan. Please
          include a copy of the Operational Assessment from last outage and a copy of the
          following documents as they become available:
          i)     Degradation Assessment
          ii)     Condition Monitoring Assessment
    c)     If you are planning on modifying your Technical Specifications such that they are
          consistent with TSTF-449, please provide copies of your correspondence with
          the NRC regarding deviations from the STS.
    d)     Copy of SG history documentation given to vendors performing eddy current (ET)
          testing of the SGs during the upcoming outage.
    e)     Copy of SG Eddy Current Data Analyst Guidelines and Site Validated Eddy
          Current Technique Specification Sheets (ETSS). Additionally, please provide a
          copy of EPRI Appendix H ETSS Qualification Records.
    f)     Identify and quantify any SGT leakage experienced during the previous operating
          cycle. Also provide documentation identifying which SG was leaking and
          corrective actions completed or planned for this condition. (If applicable)
    g)     Provide past history of the condition and issues pertaining to the secondary side
          of the steam generators (including items such as loose parts, fouling, top of tube
          sheet condition, crud removal amounts, etc.).
                                        -3-                                       Enclosure
 
    h)     Please provide copies of your most recent self assessments of the SG
          monitoring, loose parts monitoring, and secondary side water chemistry control
          programs.
    i)     Please also indicate where the primary, secondary, and resolution analyses are
          scheduled to take place.
    j)     Please provide a summary of the scope of the SGT examinations, including
          examination methods such as Bobbin, Rotating Pancake, or Plus Point, and the
          percentage of tubes to be examined. *Do not provide these documents
          separately if already included in other information requested.
A.5 Materials Reliability (MRP-139) Program Activities
    a)     A list of, with verification, that the baseline inspections of all applicable Dissimilar
          Metal Butt Welds (DMBWs) have been completed by September 28, 2009.
    b)     Verification that baseline inspection of hot leg and cold leg temperature DMBWs
          have been included in the inspection program and that the schedules for the
          baseline inspections are consistent with the baseline schedules in MRP-139.
    c)     A list and schedule (examination dates) of all DMBW examinations planned for
          the upcoming refueling outage. If none are scheduled, then data from previous
          examinations should be available for review.
    d)     A list and schedule for any welding to be performed on DMBWs in the upcoming
          outage. If no welding will be performed then records of previous welding on
          DMBWs and postweld NDE documentation.
    e)     A list and schedule of any stress improvement (SI) activities planned for the
          upcoming refueling outage. If none are scheduled then have qualification reports
          for any SIs previously performed.
    f)     Documentation and description of how the baseline and inservice inspection
          specifications in MRP-139 are satisfied at your facility.
    g)     A list of weld locations controlled by MRP-139 which includes the MRP-139 weld
          category, pre-mitigation volumetric examination date, type of mitigation or stress
          improvement, post mitigation volumetric examination date, and plans for future
          MRP-139 required examinations.
A.6 Additional information related to all ISI activities
    a)     A list with a brief description of ISI, BACCP, and SGT inspection related issues
          (e.g., condition reports) entered into your corrective action program since the
          beginning of the last refueling outage. For example, a list based upon data base
          searches using key words related to piping or SG tube degradation such as: ISI,
          ASME Code, Section XI, NDE, cracks, wear, thinning, leakage, rust, corrosion,
          boric acid, or errors in piping/SGT examinations.
                                          -4-                                         Enclosure
 
    b)     Please provide names and phone numbers for the following program leads:
          ISI contacts (Examination, planning)
          Containment Exams
          RPVH Exams
          Snubbers and Supports
          Repair and Replacement Program Manager
          Licensing Contact
          Site Welding Engineer
          Boric Acid Corrosion Control Program
          SG Inspection Activities (site lead and vendor contact)
B. Information to be provided onsite to the inspector(s) at the entrance meeting (October
    16, 2009):
B.1 ISI / Welding Programs and Schedule Information
    a)     Updated schedules for ISI/NDE activities, including SGT inspections, planned
          welding activities, and schedule showing contingency repair plans, if available.
    b)     For ASME Code Class 1 and 2 welds selected by the inspector from the lists
          provided from section A of this enclosure, please provide copies of the following
          documentation for each subject weld:
          i)     Weld data sheet (traveler)
          ii)     Weld configuration and system location
          iii)   Applicable Code Edition and Addenda for weldment
          iv)     Applicable Code Edition and Addenda for welding procedures
          v)     Applicable weld procedures (WPS) used to fabricate the welds
          vi)     Copies of procedure qualification records (PQRs) supporting the WPS
                  from B.1.b.v
          vii)   Copies of mechanical test reports identified in the PQRs above
          viii)   Copies of the nonconformance reports for the selected welds (If
                  applicable)
          ix)     Radiographs of the selected welds and access to equipment to allow
                  viewing radiographs (If RT was performed)
          x)     Copies of the preservice examination records for the selected welds
          xi)     Copies of welder performance qualifications records applicable to the
                  selected welds, including documentation that welder maintained
                  proficiency in the applicable welding processes specified in the WPS (at
                  least six months prior to the date of subject work)
          xii)   Copies of NDE personnel qualifications (VT, PT, UT, RT), as applicable
    c)     For the ISI related corrective action issues selected by the inspector(s) from
          section A of this enclosure, provide a copy of the corrective actions and
          supporting documentation.
    d)     For the NDE reports with relevant conditions on Code Class 1 & 2 systems
          selected by the inspector from section A above, provide a copy of the
                                        -5-                                       Enclosure
 
          examination records, examiner qualification records, and associated corrective
          action documents.
    e)     A copy of (or ready access to) most current revision of the ISI Program Manual
          and Plan for the current Interval.
    f)     For the NDEs selected by the inspector from section A of this enclosure, provide
          copy of the NDE procedures used to perform the examinations (including
          calibration and flaw characterization/sizing procedures). For ultrasonic
          examination procedures qualified in accordance with ASME Code, Section XI,
          Appendix VIII, provide documentation supporting the procedure qualification
          (e.g., the EPRI performance demonstration qualification summary sheets). Also,
          include qualification documentation of the specific equipment to be used (e.g.,
          ultrasonic unit, cables, and transducers including serial numbers) and NDE
          personnel qualification records.
B.2 Reactor Pressure Vessel Head (RPVH)
    a)     Provide the NDE personnel qualification records for the examiners who will
          perform examinations of the RPVH.
    b)     Provide drawings showing the following: (If a visual examination is planned for
          the upcoming refueling outage).
          i)       RPVH and CRDM nozzle configurations
          ii)     RPVH insulation configuration
    The drawings listed above should include fabrication drawings for the nozzle attachment
    welds as applicable.
    c)     Copy of NDE reports from the last RPVH examination.
    d)     Copy of evaluation or calculation demonstrating that the scope of the visual
          examination of the upper head will meet the 95 percent minimum coverage
          required by NRC Order EA-03-009 (If a visual examination is planned for the
          upcoming refueling outage).
    e)     Provide a copy of the procedures that will be used to identify the source of any
          boric acid deposits identified on the RPVH. If no explicit procedures exist which
          govern this activity, provide a description of the process to be followed including
          personnel responsibilities and expectations.
    f)     Provide a copy of the updated calculation of effective degradation years (EDY)
          for the RPVH susceptibility ranking.
    g)     Provide copy of the vendor qualification report(s) that demonstrates the detection
          capability of the NDE equipment used for the RPVH examinations. Also, identify
          any changes in equipment configurations used for the RPVH examinations which
          differ from that used in the vendor qualification report(s).
                                        -6-                                       Enclosure
 
B.3 Boric Acid Corrosion Control Program (BACCP)
    a)     Please provide boric acid walkdown inspection results, an updated list of boric
          acid leaks identified so far this outage, associated corrective action
          documentation, and overall status of planned boric acid inspections.
    b)     Please provide any engineering evaluations completed for boric acid leaks
          identified since the end of the last refueling outage. Please include a status of
          corrective actions to repair and/or clean these boric acid leaks. Please identify
          specifically which known leaks, if any, have remained in service or will remain in
          service as active leaks.
B.4 Steam Generator Tube (SGT) Inspections
    a)     Copies of the Examination Technique Specification Sheets (ETSS) and
          associated justification for any revisions.
    b)     Copy of the guidance to be followed if a loose part or foreign material is identified
          in the SGs.
    c)     Please provide a copy of the ET procedures used to perform the SGT
          inspections (specifically calibration and flaw characterization/sizing procedures,
          etc.). Also include documentation for the specific equipment to be used.
    d)     Please provide copies of your responses to NRC and industry operating
          experience communications such as Generic Letters, Information Notices, etc.
          (as applicable to SGT inspections) *Do not provide these documents separately if
          already included in other information requested such as the degradation
          assessment.
    e)     List of corrective action documents generated by the vendor and/or site with
          respect to SG inspection activities.
B.5 Codes and Standards
B.5 Codes and Standards
  a) Ready access to (i.e., copies provided to the inspector(s) for use during the inspection at the onsite inspection location, or room number and location where available):  
    a)     Ready access to (i.e., copies provided to the inspector(s) for use during the
i) Applicable Editions of the ASME Code (Sections V, IX and XI) for the inservice inspection program and the repair/replacement program.
          inspection at the onsite inspection location, or room number and location where
ii) EPRI and industry standards referenced in the procedures used to perform the SGT eddy current examination.  
          available):
 
          i)       Applicable Editions of the ASME Code (Sections V, IX and XI) for the
  - 8 - Enclosure  
                    inservice inspection program and the repair/replacement program.
Inspector Contact Information:  
          ii)     EPRI and industry standards referenced in the procedures used to
Ronald A. Kopriva   James Drake     Senior Reactor Inspector Senior Reactor Inspector   817-860-8104   817-276-6558    
                    perform the SGT eddy current examination.
Ron.kopriva@nrc.gov  
                                        -7-                                       Enclosure
  James.Drake@nrc.gov
 
  Mailing Address: US NRC Region IV  
Inspector Contact Information:
Attn: Ron Kopriva 612 E. Lamar Blvd, Suite 400 Arlington, TX 76011
Ronald A. Kopriva             James Drake
Senior Reactor Inspector       Senior Reactor Inspector
817-860-8104                   817-276-6558
Ron.kopriva@nrc.gov           James.Drake@nrc.gov
Mailing Address:
US NRC Region IV
Attn: Ron Kopriva
612 E. Lamar Blvd, Suite 400
Arlington, TX 76011
                                    -8-                Enclosure
}}
}}

Latest revision as of 04:16, 14 November 2019

Notification of Inspection (NRC Inspection Report 05000482-09-005 and Request for Information
ML091910434
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 07/10/2009
From: Thomas Farnholtz
Region 4 Engineering Branch 1
To: Muench R
Wolf Creek
References
IR-09-005
Download: ML091910434 (12)


See also: IR 05000482/2009005

Text

UNITED STATES

NUC LE AR RE G UL AT O RY C O M M I S S I O N

R E GI ON I V

612 EAST LAMAR BLVD , SU I TE 400

AR LI N GTON , TEXAS 76011-4125

July 10, 2009

Rick A. Muench, President and

Chief Executive Officer

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

SUBJECT: WOLF CREEK GENERATING STATION - NOTIFICATION OF INSPECTION

(NRC INSPECTION REPORT 05000482/2009005 ) AND REQUEST FOR

INFORMATION

Dear Mr. Muench,

From October 15 through October 30, 2009, reactor inspectors from the Nuclear Regulatory

Commissions (NRC) Region IV office will perform the baseline inservice inspection at the Wolf

Creek Generating Station, using NRC Inspection Procedure 71111.08, "Inservice Inspection

Activities," and TI 2515/172, "Reactor Coolant System Dissimilar Metal Butt Welds." Experience

has shown that this inspection is a resource intensive inspection both for the NRC inspectors

and your staff. In order to minimize the impact to your onsite resources and to ensure a

productive inspection, we have enclosed a request for documents needed for this inspection.

These documents have been divided into two groups. The first group (Section A of the

enclosure) identified information to be provided prior to the inspection to ensure that the

inspectors are adequately prepared. The second group (Section B of the enclosure) identifies

the information the inspectors will need upon arrival at the site. It is important that all of these

documents are up to date and complete in order to minimize the number of additional

documents requested during the preparation and/or the onsite portions of the inspection.

We have discussed the schedule for these inspection activities with your staff and understand

that our regulatory contact for this inspection will be Mr. William Muilenberg, of your licensing

organization. Our inspection dates are subject to change based on your updated schedule of

outage activities. If there are any questions about this inspection or the material requested,

please contact the lead inspector Ronald A. Kopriva, at (817) 860-8104, or

ron.kopriva@nrc.gov.

In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice," a copy of this letter and its

enclosure will be available electronically for public inspection in the NRC Public Document

Room or from the Publicly Available Records (PARS) component of NRCs document

system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-

rm/adams.html (the Public Electronic Reading Room).

Wolf Creek Nuclear Operating Corporation -2-

Sincerely,

/RA/

Thomas Farnholtz, Chief

Engineering Branch 1

Division of Reactor Safety

Docket: 50-482

License: NPF-42

Enclosure:

Inservice Inspection Document Request

Vice President Operations/Plant Manager

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Jay Silberg, Esq.

Pillsbury Winthrop Shaw Pittman LLP

2300 N Street, NW

Washington, DC 20037

Supervisor Licensing

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Chief Engineer

Utilities Division

Kansas Corporation Commission

1500 SW Arrowhead Road

Topeka, KS 66604-4027

Office of the Governor

State of Kansas

Topeka, KS 66612-1590

Attorney General

120 S.W. 10th Avenue, 2nd Floor

Topeka, KS 66612-1597

County Clerk

Coffey County Courthouse

110 South 6th Street

Burlington, KS 66839

Wolf Creek Nuclear Operating Corporation -3-

Chief, Radiation and Asbestos

Control Section

Bureau of Air and Radiation

Kansas Department of Health and

Environment

1000 SW Jackson, Suite 310

Topeka, KS 66612-1366

Chief, Technological Hazards

Branch

FEMA, Region VII

9221 Ward Parkway

Suite 300

Kansas City, MO 64114-3372

Wolf Creek Nuclear Operating Corporation -4-

Electronic distribution by RIV:

Regional Administrator (Elmo.Collins@nrc.gov )

Deputy Regional Administrator (Chuck.Casto@nrc.gov )

DRP Director (Dwight.Chamberlain@nrc.gov )

DRP Deputy Director (Anton.Vegel@nrc.gov )

DRS Director (Roy.Caniano@nrc.gov )

DRS Deputy Director (Troy.Pruett@nrc.gov )

Senior Resident Inspector (Chris.Long@nrc.gov )

Resident Inspector (Charles.Peabody@nrc.gov )

Site Secretary (Shirley.Allen@nrc.gov )

Branch Chief, DRP/B (Vincent.Gaddy@nrc.gov )

Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov )

Public Affairs Officer (Victor.Dricks@nrc.gov )

Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov )

RITS Coordinator (Marisa.Herrera@nrc.gov )

Regional Counsel (Karla.Fuller@nrc.gov )

Congressional Affairs Officer (Jenny.Weil@nrc.gov )

OEMail Resource

SUNSI Review Completed: ___Y___ ADAMS: 7 Yes No Initials: ___TRF_

7 Publicly Available Non-Publicly Available Sensitive 7 Non-Sensitive

S:\DRS\REPORTS\WC 2009005 RFI -RAK ML091910434

SRI:EB1 C:EB1

RAKopriva TFarnholtz

/RA/ /RA/

7/8/09 7/10/09

OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax

INSERVICE INSPECTION DOCUMENT REQUEST

Inspection Dates: October 15 through October 30, 2009

Inspection Procedures: IP 71111.08 "Inservice Inspection (ISI) Activities"

TI 2515/172 "Reactor Coolant System Dissimilar Metal Butt Welds"

Inspectors: Ronald A. Kopriva, Senior Reactor Inspector (Lead Inspector - ISI)

James Drake, Senior Reactor Inspector

A. Information Requested for the In-Office Preparation Week

The following information should be sent to the Region IV office in hard copy or

electronic format (ims.certrec.com preferred), in care of Ronald A. Kopriva, by

September 28, 2009, to facilitate the selection of specific items that will be reviewed

during the onsite inspection week. The inspector will select specific items from the

information requested below and then request from your staff additional documents

needed during the onsite inspection week (Section B of this enclosure). We ask that the

specific items selected from the lists be available and ready for review on the first day of

inspection. *Please provide requested documentation electronically if possible. If

requested documents are large and only hard copy formats are available, please inform

the inspector(s), and provide subject documentation during the first day of the onsite

inspection. If you have any questions regarding this information request, please call the

inspector as soon as possible.

A.1 ISI/Welding Programs and Schedule Information

a) A detailed schedule (including preliminary dates) of:

i) Nondestructive examinations (NDEs) planned for Class 1 & 2 systems

and containment, performed as part of your ASME Section XI, Risk

Informed (if applicable), and augmented ISI programs during the

upcoming outage.

Provide a status summary of the NDE inspection activities vs. the

required inspection period percentages for this Interval by category per

ASME Section XI, IWX-2400 (Do not provide separately if other

documentation requested contains this information)

ii) Reactor pressure vessel head (RPVH) examinations planned for the

upcoming outage.

iii) Examinations planned for Alloy 82/182/600 components that are not

included in the Section XI scope. (If applicable)

iv) Examinations planned as part of your Boric Acid Corrosion Control

Program (Mode 3 walkdowns, bolted connection walkdowns, etc.)

-1- Enclosure

v) Welding activities that are scheduled to be completed during the

upcoming outage (ASME Class 1, 2, or 3 structures, systems, or

components (SSCs))

b) A copy of ASME Section XI Code Relief Requests and associated NRC Safety

Evaluations applicable to the examinations identified above.

c) A list of NDE reports (ultrasonic, radiography, magnetic particle, dye penetrate,

Visual VT-1, VT-2, and VT-3), which have identified relevant conditions on Code

Class 1 & 2 systems since the beginning of the last refueling outage. This should

include the previousSection XI pressure test(s) conducted during start up and

any evaluations associated with the results of the pressure tests. Also, include in

the list the NDE reports with relevant conditions in the RPVH penetration nozzles

which have been accepted for continued service. The list of NDE reports should

include a brief description of the SSC where the relevant condition was identified.

d) A list with a brief description (e.g., system, material, pipe size, weld number, and

NDE performed) of the welds in Code Class 1 and 2 systems which have been

fabricated due to component repair/replacement activities since the beginning of

the last refueling outage, or are planned to be fabricated this refueling outage.

e) If reactor vessel weld examinations required by the ASME Code are scheduled to

occur during the upcoming outage, provide a detailed description of the welds to

be examined and the extent of the planned examination. Please also provide

reference numbers for applicable procedures that will be used to conduct these

examinations.

f) Copy of any 10 CFR Part 21 reports applicable to your SSCs within the scope of

Section XI of the ASME Code that have been identified since the beginning of the

last refueling outage.

g) A list of any temporary non-code repairs in service (e.g., pinhole leaks).

h) Please provide copies of the most recent self assessments for the ISI, Welding,

and Alloy 600 Programs.

A.2 Reactor Pressure Vessel Head (RPVH)

a) Provide the detailed scope of the planned NDE of the reactor vessel head which

identifies the types of NDE methods to be used on each specific part of the

vessel head to fulfill commitments made in response to NRC Bulletin 2002-02

and NRC Order EA-03-009. Also, include examination scope expansion criteria

and planned expansion sample sizes if relevant conditions are identified. (If

applicable)

b) A list of the standards and/or requirements that will be used to evaluate

indications identified during NDE of the reactor vessel head (e.g., the specific

industry or procedural standards which will be used to evaluate potential leakage

and/or flaw indications).

-2- Enclosure

A.3 Boric Acid Corrosion Control Program (BACCP)

a) Copy of the procedures that govern the scope, equipment and implementation of

the inspections required to identify boric acid leakage and the procedures for

boric acid leakage/corrosion evaluation.

b) Please provide a list of leaks (including Code class of the components) that have

been identified since the last refueling outage and associated corrective action

documentation. If during the last cycle, the Unit was shutdown, please provide

documentation of containment walkdown inspections performed as part of the

BACCP.

c) Please provide a copy of the most recent self-assessment performed for the

BACCP.

A.4 Steam Generator Tube (SGT) Inspections

a) A detailed schedule of:

i) SGT inspection, data analyses, and repair activities for the upcoming

outage. (If occurring)

ii) SG secondary side inspection activities for the upcoming outage. (If

occurring)

b) Please provide a copy of your SG ISI Inspection Program and Plan. Please

include a copy of the Operational Assessment from last outage and a copy of the

following documents as they become available:

i) Degradation Assessment

ii) Condition Monitoring Assessment

c) If you are planning on modifying your Technical Specifications such that they are

consistent with TSTF-449, please provide copies of your correspondence with

the NRC regarding deviations from the STS.

d) Copy of SG history documentation given to vendors performing eddy current (ET)

testing of the SGs during the upcoming outage.

e) Copy of SG Eddy Current Data Analyst Guidelines and Site Validated Eddy

Current Technique Specification Sheets (ETSS). Additionally, please provide a

copy of EPRI Appendix H ETSS Qualification Records.

f) Identify and quantify any SGT leakage experienced during the previous operating

cycle. Also provide documentation identifying which SG was leaking and

corrective actions completed or planned for this condition. (If applicable)

g) Provide past history of the condition and issues pertaining to the secondary side

of the steam generators (including items such as loose parts, fouling, top of tube

sheet condition, crud removal amounts, etc.).

-3- Enclosure

h) Please provide copies of your most recent self assessments of the SG

monitoring, loose parts monitoring, and secondary side water chemistry control

programs.

i) Please also indicate where the primary, secondary, and resolution analyses are

scheduled to take place.

j) Please provide a summary of the scope of the SGT examinations, including

examination methods such as Bobbin, Rotating Pancake, or Plus Point, and the

percentage of tubes to be examined. *Do not provide these documents

separately if already included in other information requested.

A.5 Materials Reliability (MRP-139) Program Activities

a) A list of, with verification, that the baseline inspections of all applicable Dissimilar

Metal Butt Welds (DMBWs) have been completed by September 28, 2009.

b) Verification that baseline inspection of hot leg and cold leg temperature DMBWs

have been included in the inspection program and that the schedules for the

baseline inspections are consistent with the baseline schedules in MRP-139.

c) A list and schedule (examination dates) of all DMBW examinations planned for

the upcoming refueling outage. If none are scheduled, then data from previous

examinations should be available for review.

d) A list and schedule for any welding to be performed on DMBWs in the upcoming

outage. If no welding will be performed then records of previous welding on

DMBWs and postweld NDE documentation.

e) A list and schedule of any stress improvement (SI) activities planned for the

upcoming refueling outage. If none are scheduled then have qualification reports

for any SIs previously performed.

f) Documentation and description of how the baseline and inservice inspection

specifications in MRP-139 are satisfied at your facility.

g) A list of weld locations controlled by MRP-139 which includes the MRP-139 weld

category, pre-mitigation volumetric examination date, type of mitigation or stress

improvement, post mitigation volumetric examination date, and plans for future

MRP-139 required examinations.

A.6 Additional information related to all ISI activities

a) A list with a brief description of ISI, BACCP, and SGT inspection related issues

(e.g., condition reports) entered into your corrective action program since the

beginning of the last refueling outage. For example, a list based upon data base

searches using key words related to piping or SG tube degradation such as: ISI,

ASME Code,Section XI, NDE, cracks, wear, thinning, leakage, rust, corrosion,

boric acid, or errors in piping/SGT examinations.

-4- Enclosure

b) Please provide names and phone numbers for the following program leads:

ISI contacts (Examination, planning)

Containment Exams

RPVH Exams

Snubbers and Supports

Repair and Replacement Program Manager

Licensing Contact

Site Welding Engineer

Boric Acid Corrosion Control Program

SG Inspection Activities (site lead and vendor contact)

B. Information to be provided onsite to the inspector(s) at the entrance meeting (October

16, 2009):

B.1 ISI / Welding Programs and Schedule Information

a) Updated schedules for ISI/NDE activities, including SGT inspections, planned

welding activities, and schedule showing contingency repair plans, if available.

b) For ASME Code Class 1 and 2 welds selected by the inspector from the lists

provided from section A of this enclosure, please provide copies of the following

documentation for each subject weld:

i) Weld data sheet (traveler)

ii) Weld configuration and system location

iii) Applicable Code Edition and Addenda for weldment

iv) Applicable Code Edition and Addenda for welding procedures

v) Applicable weld procedures (WPS) used to fabricate the welds

vi) Copies of procedure qualification records (PQRs) supporting the WPS

from B.1.b.v

vii) Copies of mechanical test reports identified in the PQRs above

viii) Copies of the nonconformance reports for the selected welds (If

applicable)

ix) Radiographs of the selected welds and access to equipment to allow

viewing radiographs (If RT was performed)

x) Copies of the preservice examination records for the selected welds

xi) Copies of welder performance qualifications records applicable to the

selected welds, including documentation that welder maintained

proficiency in the applicable welding processes specified in the WPS (at

least six months prior to the date of subject work)

xii) Copies of NDE personnel qualifications (VT, PT, UT, RT), as applicable

c) For the ISI related corrective action issues selected by the inspector(s) from

section A of this enclosure, provide a copy of the corrective actions and

supporting documentation.

d) For the NDE reports with relevant conditions on Code Class 1 & 2 systems

selected by the inspector from section A above, provide a copy of the

-5- Enclosure

examination records, examiner qualification records, and associated corrective

action documents.

e) A copy of (or ready access to) most current revision of the ISI Program Manual

and Plan for the current Interval.

f) For the NDEs selected by the inspector from section A of this enclosure, provide

copy of the NDE procedures used to perform the examinations (including

calibration and flaw characterization/sizing procedures). For ultrasonic

examination procedures qualified in accordance with ASME Code,Section XI,

Appendix VIII, provide documentation supporting the procedure qualification

(e.g., the EPRI performance demonstration qualification summary sheets). Also,

include qualification documentation of the specific equipment to be used (e.g.,

ultrasonic unit, cables, and transducers including serial numbers) and NDE

personnel qualification records.

B.2 Reactor Pressure Vessel Head (RPVH)

a) Provide the NDE personnel qualification records for the examiners who will

perform examinations of the RPVH.

b) Provide drawings showing the following: (If a visual examination is planned for

the upcoming refueling outage).

i) RPVH and CRDM nozzle configurations

ii) RPVH insulation configuration

The drawings listed above should include fabrication drawings for the nozzle attachment

welds as applicable.

c) Copy of NDE reports from the last RPVH examination.

d) Copy of evaluation or calculation demonstrating that the scope of the visual

examination of the upper head will meet the 95 percent minimum coverage

required by NRC Order EA-03-009 (If a visual examination is planned for the

upcoming refueling outage).

e) Provide a copy of the procedures that will be used to identify the source of any

boric acid deposits identified on the RPVH. If no explicit procedures exist which

govern this activity, provide a description of the process to be followed including

personnel responsibilities and expectations.

f) Provide a copy of the updated calculation of effective degradation years (EDY)

for the RPVH susceptibility ranking.

g) Provide copy of the vendor qualification report(s) that demonstrates the detection

capability of the NDE equipment used for the RPVH examinations. Also, identify

any changes in equipment configurations used for the RPVH examinations which

differ from that used in the vendor qualification report(s).

-6- Enclosure

B.3 Boric Acid Corrosion Control Program (BACCP)

a) Please provide boric acid walkdown inspection results, an updated list of boric

acid leaks identified so far this outage, associated corrective action

documentation, and overall status of planned boric acid inspections.

b) Please provide any engineering evaluations completed for boric acid leaks

identified since the end of the last refueling outage. Please include a status of

corrective actions to repair and/or clean these boric acid leaks. Please identify

specifically which known leaks, if any, have remained in service or will remain in

service as active leaks.

B.4 Steam Generator Tube (SGT) Inspections

a) Copies of the Examination Technique Specification Sheets (ETSS) and

associated justification for any revisions.

b) Copy of the guidance to be followed if a loose part or foreign material is identified

in the SGs.

c) Please provide a copy of the ET procedures used to perform the SGT

inspections (specifically calibration and flaw characterization/sizing procedures,

etc.). Also include documentation for the specific equipment to be used.

d) Please provide copies of your responses to NRC and industry operating

experience communications such as Generic Letters, Information Notices, etc.

(as applicable to SGT inspections) *Do not provide these documents separately if

already included in other information requested such as the degradation

assessment.

e) List of corrective action documents generated by the vendor and/or site with

respect to SG inspection activities.

B.5 Codes and Standards

a) Ready access to (i.e., copies provided to the inspector(s) for use during the

inspection at the onsite inspection location, or room number and location where

available):

i) Applicable Editions of the ASME Code (Sections V, IX and XI) for the

inservice inspection program and the repair/replacement program.

ii) EPRI and industry standards referenced in the procedures used to

perform the SGT eddy current examination.

-7- Enclosure

Inspector Contact Information:

Ronald A. Kopriva James Drake

Senior Reactor Inspector Senior Reactor Inspector

817-860-8104 817-276-6558

Ron.kopriva@nrc.gov James.Drake@nrc.gov

Mailing Address:

US NRC Region IV

Attn: Ron Kopriva

612 E. Lamar Blvd, Suite 400

Arlington, TX 76011

-8- Enclosure