ENS 46465: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 12/08/2010 13:00 CST | | event date = 12/08/2010 13:00 CST | ||
| last update date = 12/08/2010 | | last update date = 12/08/2010 | ||
| title = Stuck Shutter | | title = Stuck Shutter on Berthold Model P2608-100 Due to Cement Dust Buildup | ||
| event text = While performing semi-annual shutter checks on a Berthold Waybelt Scale Process Gauge Model P2608-100 containing 5 milliCuries of Cobalt 60, a technician found the shutter partially open and was not able to fully close the shutter due to cement dust buildup on the shutter mechanism. The gauge is located in a secure guarded location not readily accessible to personnel, and does not present a hazard to personnel. The company will shut down the process line on 12/21/10 and perform repairs to the process gauge at that time. | | event text = While performing semi-annual shutter checks on a Berthold Waybelt Scale Process Gauge Model P2608-100 containing 5 milliCuries of Cobalt 60, a technician found the shutter partially open and was not able to fully close the shutter due to cement dust buildup on the shutter mechanism. The gauge is located in a secure guarded location not readily accessible to personnel, and does not present a hazard to personnel. The company will shut down the process line on 12/21/10 and perform repairs to the process gauge at that time. | ||
| URL = http://www.nrc.gov/reading-rm/doc-collections/event-status/event/2010/20101209en.html#en46465 | | URL = http://www.nrc.gov/reading-rm/doc-collections/event-status/event/2010/20101209en.html#en46465 |
Latest revision as of 21:08, 1 March 2018
Where | |
---|---|
Continental Cement Hannibal, Missouri (NRC Region 3) | |
License number: | 24-20263-01 |
Organization: | Continental Cement |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+-4.72 h-0.197 days <br />-0.0281 weeks <br />-0.00647 months <br />) | |
Opened: | William E. Sherman Jr. 14:17 Dec 8, 2010 |
NRC Officer: | Joe O'Hara |
Last Updated: | Dec 8, 2010 |
46465 - NRC Website | |