ENS 47325: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
Line 16: Line 16:
| event date = 10/05/2011 14:00 EDT
| event date = 10/05/2011 14:00 EDT
| last update date = 10/06/2011
| last update date = 10/06/2011
| title = Item Relied On For Safety Not As Described In The Integrated Safety Analysis
| title = Item Relied on for Safety Not as Described in the Integrated Safety Analysis
| event text = During a review of the Integrated Safety Analysis (ISA) for a 3-gallon can elevator used in the Dry Scrap Recycle (DSR) area, it was determined that the ISA incorrectly describes the IROFS used to control movement of SNM. The system is composed of two sequential can elevators that are used to move SNM to different floors. A Fuel Business System (FBS) automated control and associated gate controls are designated as one of the Items Relied On For Safety (IROFS). In the ISA, this IROFS is incorrectly attributed to the 2nd can elevator instead of the 1st can elevator. Based on a review of this condition, determined at approximately 1400 on October 5, 2011, it was determined that the system was different than analyzed in the ISA and resulted in a failure to meet performance requirements.
| event text = During a review of the Integrated Safety Analysis (ISA) for a 3-gallon can elevator used in the Dry Scrap Recycle (DSR) area, it was determined that the ISA incorrectly describes the IROFS used to control movement of SNM. The system is composed of two sequential can elevators that are used to move SNM to different floors. A Fuel Business System (FBS) automated control and associated gate controls are designated as one of the Items Relied On For Safety (IROFS). In the ISA, this IROFS is incorrectly attributed to the 2nd can elevator instead of the 1st can elevator. Based on a review of this condition, determined at approximately 1400 on October 5, 2011, it was determined that the system was different than analyzed in the ISA and resulted in a failure to meet performance requirements.
The FBS and associated gate control were in place at all times on the 1st can elevator, was operating correctly, and supported by management measures. No unsafe condition existed. The ISA and associated documentation are being updated to designate the correct can elevator and associated controls.
The FBS and associated gate control were in place at all times on the 1st can elevator, was operating correctly, and supported by management measures. No unsafe condition existed. The ISA and associated documentation are being updated to designate the correct can elevator and associated controls.

Revision as of 21:05, 1 March 2018

ENS 47325 +/-
Where
Global Nuclear Fuel - Americas
Wilmington, North Carolina (NRC Region 2)
License number: Snm-1097
Reporting
Part 70 App A (B)(1)
Time - Person (Reporting Time:+19.27 h0.803 days <br />0.115 weeks <br />0.0264 months <br />)
Opened: Phillip Ollis
13:16 Oct 6, 2011
NRC Officer: Bill Huffman
Last Updated: Oct 6, 2011
47325 - NRC Website
Loading map...