The gauge operator remained with the gauge while securing the 15 feet perimeter and contacting the on-site foreman for the subcontractor, the superintendent for the contractor, and GME Testing's RSO.  
The gauge operator remained with the gauge while securing the 15 feet perimeter and contacting the on-site foreman for the subcontractor, the superintendent for the contractor, and GME Testing's RSO.  
Readings were taken at the edge of the 15 foot radius around the gauge, the 3 foot radius, the 1 foot radius, and on the surface of the gauge.  All readings gathered were within the acceptable range when compared to the the radiation profile of the gauge, as provided by the manufacturer. The damaged gauge was securely locked in its shipping case and transported to the GME Testing office.
Readings were taken at the edge of the 15 foot radius around the gauge, the 3 foot radius, the 1 foot radius, and on the surface of the gauge.  All readings gathered were within the acceptable range when compared to the the radiation profile of the gauge, as provided by the manufacturer. The damaged gauge was securely locked in its shipping case and transported to the GME Testing office.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2023/20230407en.html#en56445
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2023/20230410en.html#en56445
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 07:30, 10 April 2023

ENS 56445 +/-
Where
Gme Testing
Fort Wayne, Indiana (NRC Region 3)
License number: 13-32182-01
Organization: Gme Testing
Reporting
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure
Time - Person (Reporting Time:+217.48 h9.062 days <br />1.295 weeks <br />0.298 months <br />)
Opened: Dina Sljivo
15:36 Mar 31, 2023
NRC Officer: Bill Gott
Last Updated: Mar 31, 2023
56445 - NRC Website