Line 1: Line 1:
{{Adams
#REDIRECT [[ET 10-0012, Results of the Sixteenth Steam Generator Tube Inservice Inspection]]
| number = ML101100676
| issue date = 04/08/2010
| title = Results of the Sixteenth Steam Generator Tube Inservice Inspection
| author name = Garrett T
| author affiliation = Wolf Creek Nuclear Operating Corp
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000482
| license number =
| contact person =
| case reference number = ET 10-0012
| document type = Inservice/Preservice Inspection and Test Report, Letter
| page count = 67
}}
 
=Text=
{{#Wiki_filter:WGLF CREEK 'NUCLEAR OPERATING CORPORATION Terry J. Garrett Vice President, Engineering April 8, 2010 ET 10-0012 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
 
==Subject:==
Docket No. 50-482: Results of the Sixteenth Steam Generator Tube Inservice Inspection Gentlemen:
Attachment I, the Steam Generator Tube Inspection Report, is being submitted in accordance with Wolf Creek Generating Station (WCGS) Technical Specification (TS) 5.6.10, "Steam Generator Tube Inspection Report." This report provides the results of WCGS's sixteenth steam generator (SG) tube inservice inspection. The Steam Generator Tube Inspection Report includes the following:
: a. The scope of inspections performed on each SG;
: b. Active degradation mechanisms found;
: c. Nondestructive examination techniques utilized for each degradation mechanism;
: d. Location, orientation (if linear), and measured sizes (if available) of service induced indications;
: e. Number of tubes plugged during the inspection outage for each active degradation mechanism;
: f. Total number and percentage of tubes plugged to date; and
: g. The results of condition monitoring, including the results of tube pulls and in-situ testing; The following items are also included in accordance with the One-time Alternate Repair Criteria, H*, which was approved to support WCGS's Refueling Outage 17 and the subsequent operating cycle:
: h. Following completion of an inspection performed in Refueling Outage 17 (and any inspections performed in the subsequent operating cycle) the primary to secondary LEAKAGE rate observed in each SG (if it is not practical to assign the LEAKAGE to an individual SG, the entire primary to secondary LEAKAGE should be conservatively assumed to be from one SG) during the cycle preceding the inspection which is the subject of the report; P.O. Box 411/ Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HC/VET
 
ET 10-0012 Page 2 of 2
: i. Following completion of an inspection performed in Refueling Outage 17 (and any inspections performed in the subsequent operating cycle) the calculated accident induced leakage rate from the portion of the tubes below 13.1 inches from the top of the tubesheet for the most limiting accident in the most limiting SG. In addition, if the calculated accident induced leakage rate from the most limiting accident is less than 2.50 times the maximum operational primary to secondary leak rate, the report should describe how it was determined; and
: j. Following completion of an inspection performed in Refueling Outage 17 (and any inspections performed in the subsequent operating cycle) the results of monitoring for the tube axial displacement (slippage). If slippage is discovered, the implications of discovery and corrective action shall be provided.
Enclosures 1 and 2 contain all service-induced indications identified in SGs A and D during WCGS's Refueling Outage 17.
No commitments are contained in this correspondence.
If you have any questions concerning this matter, please contact me at (620) 364-4084, or Mr.
Richard Flannigan at (620) 364-4117.
Sincerely, Terry J. Garrett TJG/rlt Attachment : Steam Generator A Service-Induced Indications : Steam Generator D Service-Induced Indications cc:    E. E. Collins (NRC), w/a, w/e G. B. Miller (NRC), w/a, w/e B. K. Singal (NRC), w/a, w/e Senior Resident Inspector (NRC), w/a, w/e
 
Attachment to ET 10-0012 Page 1 of 7 STEAM GENERATOR TUBE INSPECTION REPORT This report is being submitted pursuant to Technical Specification (TS) 5.6.10, "Steam Generator Tube Inspection Report," to report the results of the sixteenth steam generator (SG) tube inservice inspection.
Summary The sixteenth SG tube inservice inspection was completed by Westinghouse Electric Corporation on October 27, 2009, during Refueling Outage 17 (RF17). Initial entry into MODE 4 was achieved on November 16, 2009.
Refueling Outage 17 was the second inspection of the third sequential inspection interval (60 Effective Full Power Months (EFPMs)), and is the approximate midpoint of the third inspection interval. At the Start of Refueling Outage 17 the SGs had operated for a total of 247.16 EFPMs (20.6 Effective Full Power Years (EFPYs)).
Permanent approval of an alternate repair criteria, H*, for indications within the tubesheet could not be achieved prior to Refueling Outage 17. As a result, a One-time Alternate Repair Criteria, H*, was approved which revised TS 5.5.9, "Steam Generator (SG) Program" and TS 5.6.10, "Steam Generator Tube Inspection Report" for Wolf Creek Generating Station's (WCGS's)
Refueling Outage 17 and the subsequent operating cycle. The following alternate tube repair criteria, H*, shall be applied as an alternative to the 40% depth-based criteria:
H* is the distance from the top of the tubesheet (TTS) into the tubesheet expansion region that tubes must be free of stress corrosion flaws to assure that the tubes do not pull out of the tubesheet under the limiting loads with appropriate factors of safety. For WCGS, the H*
distance is 13.1 inches. All defects below the H* distance are not relevant to the integrity of the tube. Therefore, inspection and repair below the H* distance is not required by technical specification. For Refueling Outage 17 and the subsequent operating cycle, tubes with service-induced flaws located greater than 13.1 inches below the top of the tubesheet do not require plugging. Tubes with service-induced flaws located in the portion of the tubesheet from the top of the tubesheet to 13.1 inches below the top of the tubesheet shall be plugged upon detection.
No corrosion related tube degradation mechanisms were detected in any region of the SGs.
Wear at Anti-Vibration Bar (AVB) intersections is an existing damage mechanism.
Secondary side maintenance and inspections were also performed.
The condition of the SGs has met all industry and regulatory structural and leakage integrity requirements.
Section 1 of this report describes the scope of inspections performed, including the nondestructive examination techniques utilized for each degradation mechanism.
Section 2 contains the location, orientation (if linear), and measured sizes (if available) of service induced indications.
Section 3 contains the inspection results, which include:
: a. Active degradation mechanisms found;
 
Attachment to ET 10-0012 Page 2 of 7 STEAM GENERATOR TUBE INSPECTION 'REPORT
: b. Number of tubes plugged during the inspection outage for each active degradation mechanism;
: c. Total number and percentage of tubes plugged to date;
: d. The results of condition monitoring, including the results of tube pulls and in-situ testing;
: e. The primary to secondary leakage rate observed in each SG;
: f. The calculated accident leakage rate from the portion of the tube below 13.1 inches from the top of the tubesheet for the most limiting accident in the most limiting SG; and
: g. The results of monitoring for the tube axial displacement (slippage).
 
Attachment to ET 10-0012 Page 3 of 7 STEAM GENERATOR TUBE INSPECTION REPORT Section 1: Scope and Examination Techniques of Inspections Performed The actual inspections performed during Refueling Outage 17 exceeded both the TS minimum requirements and the requirements of the Electric Power Research Institute (EPRI) Pressurized Water Reactor (PWR) Steam Generator Examination Guidelines. The following primary side inspections were performed:
* 100% Bobbin examination of tubes in SGs A and D, full length except for Rows 1 and 2, which are inspected with the bobbin from tube end to tube support plate (TSP) #7 on both the hot leg (HL) and cold leg (CL).
* 50% Row 1 and Row 2 U-bends, mid-range Plus Point examination in SG A and SG D.
* Hot leg tubesheet +3"/-13.1", mid-range Plus Point examination of SGs A and D: 55%
of tubes, including 100% of the peripheral tubes, 2 pitches into the bundle.
* Cold leg tubesheet peripheral tubes, +/- 3", mid-range Plus Point examination of SGs A and D: 100% of peripheral tubes; 2 pitches into the bundle.
* Dings (freespan) > 5 volts: 50% of all previously identified and new dings >5 volts in the hot leg (including the U-bends) with the mid-range Plus Point probe in SGs A and D.
* Dents (structures) > 2 volts: 50% of all previously identified and new dents >2 volts in the hot leg (including the U-bends) with the mid-range Plus Point probe in SGs A and D.
* Plus Point examination of all "I-code" indications that are not resolved after history review.
* Visual inspection of all plugs in SGs A and D.
* Plus Point examination of a 5% sample of bobbin indications that have not changed since the prior inspection ("H" and "S" codes).
* Plus Point inspection to bound (all surrounding tubes, at least one pitch removed) the tubes exhibiting possible loose parts (PLP) signals during the inspection.
* Plus Point inspection of a sample of tubes to support the scale profiling effort.
In addition, the following secondary side maintenance and inspections were performed:
    "  Sludge Lancing of SGs A and D.
    "  Foreign Object Search and Retrieval (FOSAR) of SGs A and D to locate, identify, and retrieve foreign objects that were present on the steam generator tubesheet. FOSAR was also performed to inspect for any Possible Loose Parts (PLP) identified during the Eddy Current Program.
    "    In-Bundle Inspection (IBI) of SGs A and D to inspect the condition of the top of the tubesheet and to augment the FOSAR effort.
* Upper Steam Drum Inspection in SG A to evaluate the condition of the upper steam drum components with regard to damage of any kind.
 
Attachment to ET 10-0012 Page 4 of 7 STEAM GENERATOR TUBE INSPECTION REPORT Section 2: Indication Listing The following Enclosures contain all service-induced indications for SGs A and D. This encompasses the location, orientation (if linear), and measured sizes (if available) of service induced indications : Steam Generator A Service-Induced Indications : Steam Generator D Service-Induced Indications The key below provides a description of the abbreviations used in the tables.
COL            Column PER            Percent LOCN          Location INCH1          Distance from location
        #H, #C        (# = Support Plate Number) Hot Leg or Cold Leg Side AV#            Anti-Vibration Bar (# = number)
TSH            Tube Sheet Hot Leg FBC            Flow Baffle Cold Leg FBH            Flow Baffle Hot Leg
 
Attachment to ET 10-0012 Page 5 of 7 STEAM GENERATOR TUBE INSPECTION REPORT Section 3: Inspection Results Active Degradation Mechanisms Found The inspection results indicate that wear at AVB locations is an active degradation mechanism in SGs A and D. Other existing degradation mechanisms include wear at the flow distribution baffle and wear due to foreign objects.
Identification of Tubes Plug.ged Steam Generator A:                    Row      Column          Attribution 40        47            AVBWear 40        75            AVBWear 44        44            AVBWear 48        81            AVBWear 49        51            AVBWear 50        71            AVBWear Administrative -
18        81 Geometric anomaly Steam Generator D:                    Row      Column        Attribution 41        59            AVBWear 45        25            AVBWear 45        81            AVBWear 46        31            AVBWear 48        39            AVBWear 48        60            AVBWear 49        29            AVBWear 49        30            AVBWear 49        67            AVBWear 49        91            AVBWear Administrative -
16                  Geometric anomaly Total Number of Tubes Plugged in Each Steam Generator Steam Generator    Total Number of      Total Percentage Tubes Plugged        Plugged A                  *42                  0.75%
B                  53                  0.94%
C                  28                  0.50%
D                    128                2.28%
*An additional 3 plugs are installed in SG A cold leg only, due to tubesheet drilling errors during manufacturing. No tubes are installed in those locations.
 
Attachment to ET 10-0012 Page 6 of 7 STEAM GENERATOR TUBE INSPECTION REPORT Results of Condition Monitorinq The examination results confirm that the Wolf Creek Generating Station (WCGS) SGs currently meet all industry and regulatory structural and leakage integrity guidance. No indications were found to exceed structural limits. No tube pulls or in-situ testing were required.
* AVB wear is an existing degradation mechanism.
* The maximum observed indication (51% through wall depth (TWD) at an AVB location) meets the structural and leakage requirements.
* Two geometric anomalies were reported from the top of tubesheet plus point program.
The plus point data indicated possible degradation in the signals but this was not confirmed by use of the Ghent probe. Both indications were co-located at the site of an axially oriented, linear geometric response running to, and through, the expansion region. The linear responses are seen in the historical data and are likely related to original SG manufacturing. The indication in SG D was present in historic data. The indication in SG A could not be found in the historic data; however, the previous data quality did not support detection of a low level signal such as this. The analyst consensus is that these indications are related to geometric variations and are not indications of degradation.        Nevertheless, Wolf Creek conservatively chose to administratively plug these tubes.
    "  Wear at the flow distribution baffle (FDB) is an existing degradation mechanism that is not progressing. FDB wear is attributed to a prior application of pressure pulse cleaning of the SGs. No new indications were reported as expected; all indications were previously reported at RF13 and RF15. The magnitude of the wear does not challenge the performance requirements for condition monitoring.
* Wear detected at three TSP intersections in SG D is an existing degradation mechanism that is not progressing. This degradation mechanism is not an operational degradation mechanism but is the result of previous transient foreign objects interacting with the tubes. The current indications of wear at the tube support plates meet the performance criteria for condition monitoring.
    "  Volumetric indications detected at the TTS have not changed since the prior inspection at RF13 and RF15. One previously reported TTS volumetric indication was not found at RF17. The reported changes in depth are small and within the normal variability of the sizing technique. The likely source of these indications is wear due a transient foreign object at a prior time. No new wear indications from foreign objects were detected. No foreign objects were found among the tubes with volumetric indications and their neighboring tubes. The largest indication is 17% TWD, which poses no challenge to the condition monitoring performance criteria.
* No corrosion related degradation mechanisms were observed.
* No degradation indications were observed related to potential precursor signals such as dents and dings, or to interferences such as permeability variations, etc.
    "  Leakage is not an issue for any indication detected. There is currently no leakage in the SGs.
    "  All plugs were found to be in acceptable condition based on visual inspection.
    "  No precursor signals (e.g., Distorted Support Indication (DSI)) were found in tubes identified as potentially having an elevated residual stress condition.
* No tube-to-tube contact wear was found on any tubes adjacent to tubes that were previously identified as potentially requiring stabilization due to continuing wear after
 
Attachment to ET 10-0012 Page 7 of 7 STEAM GENERATOR TUBE INSPECTION REPORT plugging for AVB wear. Therefore, in accordance with evaluations documented in the Degradation Assessment, stabilization of any previously plugged tubes was not required.
    " The commitment for H* to calculate accident induced leakage by a prescribed method was met. Because there is no existing normal operating leakage at WCGS and there are no damage mechanisms for which leakage is predicted, the predicted accident induced leakage for WCGS is zero. No adjustment to the administrative shutdown leakage limit is required.
* The commitment for H* to monitor for tube slippage was met. The absence of tube slippage was determined by confirming that there were no tube severances below the H* distance.
* Sludge lancing activities removed 21.5 pounds from SG A and 22 pounds from SG D.
* Foreign object search and retrieval (FOSAR) activities in SGs A and D identified and removed some minor foreign objects. Possible loose part (PLP) indications reported by eddy current testing were further evaluated by visual inspection and bounded using the Plus Point probe. No degradation was associated with any PLP indication. Minor foreign objects remaining in the SG are bounded by a prior analysis and are acceptable for continued operation. The analysis concluded that the.known foreign objects will not limit operation of the SGs.
    " Secondary side visual inspection activities performed at the top of the tubesheet in SGs A and D were successful in gathering additional information which is used to determine future maintenance and cleaning strategies. No immediate concerns were identified.
* Upper steam drum inspections in SG A collected additional data used for monitoring and trending of upper steam drum components. No immediate concerns were identified.
* Analysis of the data collected for scale profiling is currently on-going. This information is used in conjunction with visual inspection data to continue trending the condition of the secondary side of the steam generators in order to plan future maintenance and cleaning strategies. No immediate concerns are expected from this analysis.
to ET 10-0012 Steam Generator A Service-Induced Indications
 
SG    -  A    Service Induced Indications Wolf Creek 1            RFO XVIISAP 20091001      11/03/2009 13:32:20 ROW    COL    PER LOCN            INCHI1
          ------------------------------- +
1 25          8      11    AVI            .001 28        9      11    AV5            .001 27      10        11    AV5            .001 30      10        10    AV2            .001 30      10        14    AV5            .001 30      10        11    AV6            .001 35      14        11    AV1            .001 38      19      12    AV4            .001 40      19      12    AV2            .001 40      19      14    AV5            .001 35      20        15    AV3            .001 40      20        12    AV5            .001 42      22        17    AV5            .00!
38      25        14    AV2            .0 39      25        14    AV2            .001 45      25      28    AV2            .001 45      25      22    AV3            .00 45      25      19    AV4            .001 45      25      32    AV5            .001 27      26      18    AV5            .001 45      26      24    AV3            .00!
45      26      29    AV4            .001 45      26      16    AV5            .001 39      27      16    AV3            .001 40      27      16    AV2            .001
. ROW
  - - - - -.--
COL    PER LOCN
                - -- - - - -.-- --
INCH11
                                  .-- - - - - - - -
I            ST Max
 
SG - A            Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001                    1110312009 13:32:20
    ---    -..-          --+----        -+-------                  +
1 ROW        COL        PER LOCN                          INCH11
      --
      - -          - ---        I-  ---------------------          +
48        27          14      AV4                        .001 48        27          13      AV5                        .001 44        28          13      AV3                        .001 44        28          19      AV5                        .00 37        29          17      AV6                        .001 38        29          17      AV2                        .001 38        29          14      AV3                        .001 40        29          11      AV2                        .001 41        29          14      AV4                        .001 41        29          14      AV4                        .00 41        30          20      AV4                        .001 45        30          21      AV2                        .00 45        30          29      AV3                        .001 45        30          15      AV4                        .001 45        30          17      AV5                        .001 50        30          11      AV5                        .001 23        31          12      AV1                        .001 41        31          16      AV2                        .00 41        31          20      AV4                        .001 44        31          15      AV4                        .001 37        32          10      AV4                        .001 41 41 I32 32 13 27 AV2 AV3
                                                                .001I
                                                                .001 41        32          18      AV4                        .001 45        32          17      AV2                        .001 45        32          23      AV3                        .001 45        32          37 AV4                            .001 45        32          30 AV5                            .001
.  .
ROW COL
            .                ..----------------------------
PER LOCN
- ----.- ----.- ----.- --. ..- --.. ...
INCH11
                                                                ...
2                            ST Max
 
SG - A                Service Induced Indications Wolf Creek 1                      RFO XVIISAP 20091001          11/03/2009 13:32:20 1 ROW          COL          PER LOCN              INCH1I
+---      -+----+---------+------
1 45              32          15      AV6            .001 47          32          17      AV2                I00 47          32          36      AV3            .001 47          32          28      AV4            .001 47          32          16      AV5            .001 47          32          12      AV6            .001 34          33          14      AV4            .001 38          33          15      AV3            .001 45          33          31      AV4          .001 45          34          14      AV2            .001 45          34          20      AV4            .001 47          34          18      AV3            .001 47          34          11      AV4          .001 I50                34          14      AV1          .00 50          34          19      AV2          .001 50          34          11      AV3          .001 48          35          11      AV2          .001 48          35          18      AV3          .001 48          35          17      AV4          .001 48          35          21      AV5          .001 33          36          20      AV2          .001 33          36          16      AV3          .001 33          36          15      AV5          .001 35          36          18      AV5          .001 43          36          15      AV3            .001 43          36          16      AV4            .001 45          36          20      AV2            .001 47          36          15      AV2            .001
+---    ---    --
                  +---            -+-- -  -+------
I ROW COL                    PER LOCN              INCH11
+--------.---                    -+-----+-------.+
3                ST Max
 
SG          -      A      Service Induced Ind catiohs Wolf Creek 1                    RFO XVIISAP 20091001              11/03/2009 13:32:20
    .--  -- + +----.----+--        ---.------                  +
1 ROW COL PER LOCN                                        INCH11 1 36                  37    12    AV3                    .001 36          37    12    AV4                    .001 37          37    14    AV5                    .00 38          37    14    AV5                    .001 45          37    19    AV2                    .001 45          37    29    AV3                    .001 45          37    14    AV4                    .001 45          37    13    AV6                      .001 48          37    22    AV3                      .001 30          38    18    AV5                      .00 40          38    19    AV4                    .001 41            38    15    AV4                      .001 I        43            38    16    AV2                    .001 43            38    39    AV3                    .00 43            38    19    AV4                      .00I 43            38    20    AV5                      .001 45            38    15    AV1                      .001 45            38    25    AV3                      .001 45            38    22    AV4                      .001 48            38    13    TSH                      .031 39          39    20    AV3                      .001 39            39    24    AV4                      .001 39            39    17    AV5                      .001 39            39    22    AV6                      .001 39            39    22    AVI                      .00 44            39    22    AV2                      .001 44            39    17    AV3                      .001 I44                39    33    AV4                      .001 44            39    27    AV5                      .001 44            39    16    AV6                      .001
+---------------+---                      ----------
ROW            COL    PER LOCN                    INCH11
+ . .          -
                .-    . ..-
                        -  . ..--
                              -  .    .- -
                                          . --        - -  --
4                      ST Max
 
SG        A        Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001    11/0312009 13:32:20 1 ROW          COL PER LOCN                    INCH11
          ~------------------------------
38        40        19 AV2                .001 38        40        20 AV3                .001 38        40        16 AV5                .001 38        40        14 AV6                .001 41        40        18    AV2              .001 41        40        15    AV5              .001 41        40        20    AV6              .001 43        40        13    AV5              .001 44        40        12    AV1              .001 44        40        16    AV2              .001 44        40        11    AV3              .001 45        40        18    AV3              .001 45        40        30    AV4              .001 45        40        13    AV5              .001 46        40        16    AV1              .00 46        40        32    AV2              .001 46        40        38    AV4              .001 46        40        34    AV5              .001 27        41        18    AV2              .001 27        41        24    AV5              .00I 28        41        13    AV2            .001 28        41        18    AV5            .001 38        41        13    AV2            .001 38        41        29    AV3            .001 38        41        22    AV4            .001 40        41        17    AV3            .00 40        41        14    AV4            .001 44        41        17    AV4            .001 44        41        32    AV5            .00 44        41        17    AV6            .001 45        41        17    AV2            .001
.----    +----+    ----.---.    -+-----.          .
I ROW          COL    PER LOCN                INCH11
  - ----    ----.-    ------      -+-------
5              ST Max
 
SG        -  A    Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001                  1110312009 13:32:20
                ------------------------------- +
  ~IROW COL                PER LOCN                          INCH11 1 45            41      35        AV3                    .001 45      41    28        AV4                    .001 45      41    27        AV5                    .001 45      41      19        AV6                    .001 26      42      13        AV2                    .0@I 26      42      14        AV5                    .001 27      42      19        AV5                    .001 30      42      16        AV2                    .001 36      42      16        AV1                    .001 36      42      20        AV2                    .001 36      42      17        AV3                    .001 36      42      18        AV4                    .001 36      42      29        AV5                    .001 36      42      11        AV6                    .001
.            40 40 40 42 42 42 15 18 24 AV2 AV3 AV4
                                                                .001
                                                                .001
                                                                .001 40      42      18        AV5                    .001 40      42      14        AV6                    .001 56      42      11        AV6                    .001 28      43      11        AV2                    .001 36      43      23        AV2                    .001 36      43      13        AV5                    .001 41      43      12        AV2                    .001 41      43      22        AV3                    .001 41      43      11        AV4                    .001 41      43      30        AV5                    .001 41      43      13        AV6                    .001 30      44      20        AV5                    .001 35      44      12        AV5                    .001 4------------                4------------------------+
ROW        COL    PER LOCN                          INCH11
  ÷ . ...        ----.- - ---.- - - - -.- -- - -....            ..
6                            ST Max
 
SG - A            Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001              11/03/2009 13:32:20
.
--
ROW
.---
        -  -
COL
        +--.----
                  -        .
PER LOCN
                      --.
                                -------------------
                                -------------------
INCH11 38        44        16    AV5                      .001 41        44        20    AV2                      .00 41        44        26    AV3                      .001 41        44        24    AV4                      .001 41        44        18    AV5                      .001 41        44        14    AV6                      .001 43        44        17    AV3                      .001 43        44        17    AV5                      .001 44        44        41    AV2                      .001 44        44        31    AV3                      .001 44        44        27    AV4                      .001 44        44        30    AV5                      .001 44        44        27    AV6                    .001 28        45        27    AV6                    .001 28        45        16    AV6                    .001 35        45        19    AV1                    .001 35        45        21    AV2                    .001 36        45        10    AV1                    .001 36        45        21    AV2                    .001 36        45        16    AV3                    .00 36        45        22    AV4                    .001 36        45        26    AV5                    .001 36        45        20    AV6                    .001 37        45        16    AV2                    .001 37,      45        13    AV6                    .001 38        45        16    AV3                    .001 38        45        11    AV4                    .001 38        45        19    AV5                    .001 39        45        36    AV4                    .001 39        45        23    AV5                    .001 IA    38.      45  ... 19.        V5                    .01 40        45        13    AV2                    .001 40        45        13    AV3                    .001 I ROW COL              PER LOCN                        INCH11 1.. 9. 45              -36.. - AV4.--....-        ..
7                      ST Max
 
SG - A                              Service Induced Indications Wolf Creek 1                                      RFO XVIISAP 20091001                      11/03/2009 13:32:20
      ... -    -.      .---                    --.. --  --....        -  -... ..      .
* ROW                COL            PER LOCN                        INCH11 4---        -----------------------
1 40                          45            15      AV4                          .001 41                  45            16      AV5                          .00 41                  45            12      AV6                          .001 43                  45            11      AV3                          .001 44                  45            21      AV3                          .001 44                  45            22      AV4                          .00 44                  45            18      AV5                          .001 44                45              11      AV6                          .001 26                  46            13      AV2                          .001 26                  46            16      AV5                          .001 28                  46            21      AV2                          .001 28                  46            34      AV5                          .001 28                46              15      AV6                          .001 30 33                46              14
                                              .22      AV2 AV3                          .001 34                46              12      AV3                          .001 35                46              13      AV2                          .001 35                46              14      AV3                          .001 35                46              14      AV4                          .001 39                46              34      AV2                          .001 39                46              27      AV3                          .001 39                46              29      AV4                          .001 43                46              13      AV2                          .001 43                46              15      AV3                          .001 43                46              32      AV4                          .001 43                46              15      AV5                          .001 43                46              14      AV6                          .001 44                46            22      AV2                          .001 44                46            28      AV3                          .001 44                46              17      AV4                          .001
                                              -..---      -+-----.+
  @
          .---..----                  +---
ROW                COL            PER LOCN                        INCH11
  +----+----+-                          ---.----              +-------.                    +
8                      ST Max
 
SG - A              Service Induced Indications Wolf Creek 1                  RFO0XVIISAP 20091001                  11/03/2009 13:32:20
*l    ROW        COL      PER LOCN                        INCH11
    -----            -- ÷----+--        - -        -----          +
1 44            46        15        AV5                  .00 49        46        26        AV3                  .00I 49        46        20        AV4                  .00I 50        46        15        AV2                  .00 50        46        27        AV3                  .00I 50        46        22        AV4                  .00I I 32            47        15        AV5                  .00I 34        47        23        AV2                  .00 34        47        18        AV3                  .00I 47        24        AV5                  .00I 34 36        47        12        AV3                  .00I 47        15        AV5                  .00 36 47        22        AV3                  .00I 37
.          37 37 47 47 33 22 AV4 AV5
                                                                .00I
                                                                .00I
                                                              .00I 39        47        15        AV2 47        15        AV4                  *001 39 47        16        AV5                .00I 39 40        47        28          AV1                  .00I 47        43          AV2                  .00I 40 47        42          AV3                  .00I 40 47        26          AV4                  .00I 40 47        21          AV5                  .00I 40 40        47        14        AV6                  .00 47                                          *001 42                  16        AV5 47        15        AV6                  .00I 42 47        21          AV2                .00I 44 48        15        AV5                .00I 26 48        19        AV5                .00I 36
                                -----------
                          .----.---------                          +--.
1ROW          COL      PER LOCN                        INCH11
    +----+----.----+-                      -I-.------4..
9                        ST Max
 
SG - A              Service Induced Indications Wolf Creek 1                    RFO XVIISAP 20091001                  11/03/2009 13:32:20
*IROW              COL      PER LOCN                          INCH11
                ----------------------------                          +
37        48          18        AV2                    .001 37        48          13        AV3                    .001 37        48          12        AV5                    .081 38        48        27        AV2                    .00 38        48        25        AV3                    .001 38        48          15        AV4                    .001 38        48        14        AV5                    .001 40        48          18        AV5                    .001 40        48          16        AV6                    .001 44        48          11        AV2                    .001 22        49        15        AV2                    .00 22        49          10        AV6                    .001 24        49        15        AV2                    .00J 36        49        19        AV2                    .00]
I36              49        17        AV3.
36        49        19        AV4                    .001 36        49        17        AV3                    .001 40        49        18        AV2                    .001 40        49        25        AV3                    .00J 40        49        16        AV4                    .001 40        49        12        AV5                    .001 36        50        17        AV2                    .001 36        50        17        AV3                    .001 36        50        20        AV4                    .001 36        50        16        AV5                    .001 36        50        11        AV6                    .001 38        50        17        AV4                    .00 39        50        13        AV4                    .001 27        51        13        AV5                    .001 49        51        18        AV1                    .001 49        51        49        AV2                    .001
  -  ---.----      -4.-.....    - ....            .-------        +
I ROW          COL      PER LOCN                          INCH11
      .--- -- +-.--          - ---.--------------------
                                -                                    +
10                          ST Max
 
SG  - A      Service Induced Indications Wolf Creek 1      RFO XVIISAP 20091001        11/03/2109 13:32:20
.      ~----------------------------+-
  .ROW COL PER LOCN
+----. - ---+- +----- - -+-----+
INCH11 1 49        51  35 AV3            .08 49      51  32 AV4            .001 49      51  35 AV5            .001 49      51  19 AV6            .001 36      52  12  AV2            .001 38      52  22  AV3            .00 38      52  17  AV4            .001 38      52  15  AV5            .001 40      52  23  AV2            .001 40      52  16  AV3            .00 40      52  29  AV4            .001 40      52  29  AV5            .001 40      52  20  AV6            .001 43      52  20  AV2            .001 33      53  18  AV2            .001 3
43      53  15  AV3            .001 33      53  11  AV4            .00 33      53  13  AV5            .001 34      53  17  AV2            .001 36      53  17  AV6            .001 38      53  14  AV3            .001 40      53  11  AV3            .001 41      53  11  AV3            .001 42      53  19  AV2            .001 42      53  15  AV3            .001 42      53  14  AV4            .001 42      53  28  AV5            .001 I 4942      53 53  18 15  AV5 AV3            .001
                                    .081------
49      53  14  AV6            .00 IRO        COL PER LOCN          INCH1
            -----------------------
                                "
11            ST Max
 
SG - A              Service Induced Indications Wolf Creek I                      RFO XVIISAP 20091001                      11/03/2009 13:32:20
  +- - -+-    ....-    +-        -...    --  -. ------------------
RO CLPER LOCN                                        INCH11
        ----------          ---    4--      -  -    -    -    -    - -
35          54          19        AV2                      .001 35          54          15        AV3                      .001 36          54          21        AV3                      .001 36          54          17        AV5                      .001 37          54          15        AV2                        .001 40          54          12        AV2                      .001 41          54          15        AV4                        .001 41          54          33        AV5                      .001 41          54          10        AV6                      .001 42          54          15        AV4                      .001 42          54          22        AV5                        .00O 18          55          18        AV1                        .008 36          55          17        AV5                      .001 38          55          11        AVI                      .001 38          55          16        AV2                      .008 38          55          30        AV3                      .008 38          55          32        AV4                      .001 42          55          13        AV4                      .001 50          55          21        AV2                      .001 35          56          15        AV2                      .001 44          56          22        AV2                      .00 44          56          28        AV3                      .001 44          56          23        AV4                      .001 44          56          20        AV5                      .001 23          57          16        AVI                      .001 23          57          20        AV5                      .001 42          57          17        AV3                      .001
                    ---          -    .--        +.-------------------+
1 ROW          COL          PER LOCN                          INCHI)
- -....-      -....-      ---..-      ----.- ----......
12                        ST Max
 
SG    -      A    Service Induced Indications Wolf Creek 1            RFO XVIISAP 20091001                11/03/2009 13:32:20
* I ROW          COL  PER LOCN                      INCH11 4-- -----------
                          ------      +--------
  +    19-- 58 +A....+  19.. -....              .-.
19          58  19 AV1                          .001 19          58  19 AV6                          .00 31          58  19      AV2                    .001 41          58  27      AV2                    .0I 41          58  18      AV3                    .001 43          58  31      AV2                    .001 43          58  25      AV3                    .001 43          58  26      AV4                    .001 43          58  25      AV5                    .001 34          59  10      AV4                    .001 39          59  14      AV3                    .001 39          59  16      AV5                    .001 41          59  18      AV2                    .001 41          59  26      AV3                    .001 41          59  19      AV4                    .001 44          59  29      AV2                    .001 44          59  32      AV3                    .001 44          59  19      AV4                    .001 44          59  17      AV6                    .001 44          60  21      AV3                    .001 44          60  18      AV4                    .001 44          60  13      AV5                    .001 34          61  22      AV4                    .00 34          61  12      AV5                    .001 38          61  11      AV3                    .001 42          61  19      AV2                    .001 J 50            61  13      AV4                    .00 50          61  11      AV5                    .00 36          62  13      AV2                    ,00 1 ROW          COL  PER LOCN                    INCH11
  +----+----+----+---            --.------                  +
13                    ST Max
 
SG - A                            Service Induced Indications Wolf Creek 1                                RFO XVIISAP 20091001        11/03/2009 13:32:20
* .ROW                  COL            PER LOCN            INCH11
  . . . .I+
  -
  -
                      ....
      ---------------------------
                                                          -- - - -
36                  63          11        AV2            .001 36                    63          12        AV3            .001 44                    63          10        AV2            .001 37                  64            16        AV2            .00 37                    64          15        AV3            .001 37                    64          17        AV4            .001 37                  64            10        AV5            .001 57                  64            17        AV2            .001 40                  65            12        AV2            .001 44                  66            13        AV3            .00 51                  66            20        AV2            .001 51                  66            11        AV3            .001 38                  67            15        AV5            .001 42                  68            19        AV3            .001 49                  68          20        AV2            .001 49                  68            15        AV3            .001 40                  70          17        AV1            .001 40                  70          33        AV3            .001 40                  70          28        AV4            .00I 40                  70          14        AV5          .001 40                  70          12        AV6          .001 50                  70          29        AV2          .001 27                  71          15        AV2          .001 50                    71          25        AV2          .001 50                  71          42        AV3          .001 50                  71          44        AV4            .001 50                  71          46        AV5            .001
  -- -      --        - - --        ---      +- --    -    +-----
I ROW                  COL            PER LOCN            INCH11
+ . . . .          - -. . . .            . .-+-..
                                        - --..      . .-        - - -+
14            ST Max
 
SG          -      A    Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001          11/03/2009 13:32:20 ROW COL PER LOCN                            INCHll 3 ~------------------------------
A....-- - ----
                                  - ....
                        - 74.. 13..
1 37                  74    13 AVI                    .001 37        74    31 AV3                    .00l 37        74    31 AV4                    .001 37        74    31 AV5                    .001 37        74    12 AV6                    .00 39        75    23  AV3                  .001 40          75    34    AVM                .800 40          75    19  AV2                .001 40          75    37  AV3                .001 40          75    36  AV4                .001 40          75    40  AV5                .001 41          75    22  AV2                .001 41          75    27  AV3                .001 41          75    26  AV4                .001 41          75    35  AV5                .001 41          75    18  AV6                .001 O            42          75    23  AV                  .001 44          7 44          75    25  AV3                .001 44          75    28  AV4                .001 44          75    27  AV5                .001 I44              75    21  AV6                .001 39          76    22  AV2                .001 39          77    15  AV3                .001 44          77    23  AV4                .001 44          77    16  AV5                .001 58          77    10  AV6                .001 34          78    19  AV2                .I00 34          78    11  AV3                .001 34          78    22  AV5                .001 39          78    14  AV3                .00 39          78    14  AV5                .001
  .I ROW COL
    +--------------4--
PER LOCN
                                      ----.--------.
INCH11 15                  ST Max
 
SG    -  A    Service Induced Indl*at'ins Wolf Creek 1          RFO XVIISAP 20091001 11/03/2009 13:32:20
    - -- -----      +----      -+------
I ROW COL PER LOCN              INCH11
  +------------------------------
1 39        78    16 AV6          .001 39      79    15    AV3      .081 39      79    21    AV4      .001 39      79    14    AV5      .001 27    80      17 ýAV5        .001 34    80      15    AV1      .001 34    80      18    AV2      .001 40    80      19    AV2      .001 28    81      13    AV2      .001 28    81      13    AV5      .001 39    81      15    AV2      .001 39    81      18  AV4        .001 39    81      16  AV5        .001
. 1    44    81      13  AV2        .001 46    81      13  AV2        .001 46    81      10  AV3        .001 46    81      12    AV5      .00 48    81      32  AV2        .00 48    81      27  AV3        .001 48    81      18  AV4        .001 48    81      40  AV5        .001 56    81      11  AV5        .001 27    82      11  AV2        .001 27    82      17  AV5        .001 36    82      14  AV2        .001 39    82      11  AV2        .001 39    82      15  AV4        .001 40    82      20  AV2        .001 I ROW      COL    PER LOCN      INCH11
  +- ---  +----+--------+------          +
16        ST Max
 
SG    -  A        Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001    11/03/2009 13:32:20
  - -    -    - --  - ..-.---        -------
I ROW            COL    PER LOCN              INCH11
  - --.--.--.--.      -    -----    ----------
1    40          82        16  AV3              .001 40          82        17  AV4            .001 40          82        17  AV5            .001 36          83        17  AV1            .00 46          83        15  AVI            .001 46          83        14  AV2            .00I 25          84        10  AV2            .001 34          84        17    AV2            .00 34          84        17    AV3            .001 34          84        12    AV4            .00I 34          84        13    AV5            .001 36          84        14    AV5            .001 39          84        11    AV1            .001 39          84        35    AV2            .00 I    39          84        35    AV3            .001 39          84        24    AV4            .001 39          84        25    AV5            .001 39          84        22    AV6            .001 44          84        14    AV3            .001 44          84        11    AV4            .001 44          84        14    AV3            .00I 45          84        17    AV4            .001 53          84        13    AV5            .00j 33          85        16    AV4            .001 39          85        15    AV2            .001 39          85        34    AV3            .00 39          85        36    AV4            .001 39          85        23    AV5            .I0 39          85        14    AV6            .001 54          85        12 AV5                .001
. ---------------------------..
  .
ROW COL PER LOCN
              .
INCH11
                      ..---------------------------  +
17            ST Max
 
SG      - A      Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001          11/03/2009 13:32:20 I ROW        COL      PER LOCN                  INCH11 I                                                      I 1 25          86          13  AV5                  .001 30    86          13  AV5                  .001 31    86          22  AV5                  .00 36    86          11  AV2                  .00 46    86          14  AV1                  .001 46    86          19  AV2                  .00 46    86        27    AV3                  .001 46    86          15  AV4                  .001 26    87        14    AV5                  .001 30    87        18    AV5.0 39    87        17    AV1                .001 39    87        13    AV2                .001 39    87        16    AV3                .001 39    87        34    AV4                .001 39    87        16    AV5                .001 39    87        17    AVN                .001 44      87        17    AV2                .00 44      87        15    AV3                .00 50      87        20    AV6                .001 50      87        16    AV2                .001 50      87        18    AV3                .001 50      87        21    AV4                .001 50      87        24    AV5                .001 50      87        18    AV1                .001 50      87        16    AV2                .001 50      87        17    AV3                .001 50      87        20    AV4                .001 50      87        24    AV5                .001 20      88        17    AV6                .001 30      88        19    AV2                .001 1 ROW      COL      PER LOCN                  INCH11
--- ....      ... --  ....    -  ------------
18              ST Max
 
SG    -  A      Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001          11/03/2009 13:32:20
    .--- -+ ....    +....+--            +---------+
* ROW      COL        PER LOCN                  INCH11 1 30          88        18    AV5                  .001 38      89        23    AV5                  .001 39      89        16    AV4                  .001 44      89        18    AV2                  .0@
44      89        20    AV3                  .001 44      89        30    AV4                  .001 44      89        19    AV5                  .001 44      89        21    AV6                  .001 50      90        16    AV4                  .001 50      90        32    AV5                  .001 35      91        17    AV1                  .001 35      91        25    AV4                  .001 36      91        24    AV2                  .001 36      91        28    AV4                  .001 36      91        13    AV4                  .001 36      91        22    AV6                  .001 41      91        12    AV6                  .001 26      92        18    AV5                  .001 35      92        18    AV3                  .00 35      92        13    AV4                  .001 35      92        15    AV5                  .001 35      92        14    AV6                  .001 36      92        11    AV2                  .001 36      92        10    AV5                  .001 44        92        17    AV3                  .00 44        92        26    AV4                  .001 38      93        18    AV5                  .001 39      93        17 AV2                      .001 39      93        29 AV3                      .001
    - 39. .. 93-29----
                    .-.. .--                          - -
I ROW      COL        PER LOCN                  INCH11
  + . . . .  - -.. .  - -.. . .÷ . . . . ÷    . . . . . . . .
19                  ST Max
 
SG          -      A      Service Induced Indications Wolf Creek 1                          RFO XVIISAP 20091001              1110312009 13:32:20
*IROW                  COL PER LOCN
                      ~------------------------------            INCHiI
      - - -+- --.------            +---        - ------                +
39            93      18    AV4                      .001 39            93      15    AV5                      .001 39          94        14    AV3                      .00 39          94        16    AV5                      .001 20          95        15    AV6                      .001 38          95        16    AV4                    .00 38          95        20    AV5                    .001 39          95        14    AV2                    .001 39          95        18    AV3                    .001 39          95        22    AV4                    .001 39          95        13    AV5                    .001 39          96        19    AV3                    .00 39          96        19    AV4                      .001 48          96        13    AV3                    .001 48          96        14    AV5                    .001 27          97        12    AV1                    .001 27          97        18    AV2                    .001 35          97        18    AV4                    .001 37          97        14    AV2                    .001 37          97        16    AV3                    .001 37          97        12    AV4                    .00 37          97        19    AV5                    .001 37          98        12    AV2                    .001 37          98        18    AV3                    .001 38            98        20    AV3                    .001 38            98        23    AV4                    .001 39            98        11    AV3                    .001 35            99        16    AV5                    .001
  +--------------+--                      --      +--------+
I ROW                COL        PER LOCN                    INCH11
  +---            -+  ---    --- +---      -+------÷                +
20                      ST Max
 
SG - A                            Service Induced Indications Wolf Creek 1                                    RFO XVIISAP 20091001              11/03/2009 13:32:20
.    -----.---
I ROW COL
                                  ---+--        ------------
PER LOCN
                      -------------------------------4 INCH11 1 38                            99          16 AV2                      .001 38                  99          24 AV4                      .001 37 100                          13 AV3                      .00 37 100                            17 AV4                      .001 37 100                            14 AV3                      .001 37 100                            16 AV4                      .001 39              101              16    AV3                    .001 39              101              21    AV4                    .001 39              101              17    AV5                    .001 39              102              17    AV4                    .001 40              102              21    AV3                  .001 40              102              18    AV4                  .001 40              102              17    AV5                  .001 40              103              15    AV3                  .001 40              103              15    AV4                  .001 O 40                      103              17    AV6                  .00 43              103              15    AV3                  .001 38              106              175    AV4                  .001 38              106              14    AV5                  .001 26              109              18    AV2                  .001 27              109              19    AV2                    eel 36              109              16    AV4                  .001 36              110              18    AV2                  .001 36              110              16    AV3                  .001 36              110              29    AV4                  .001 36              110              37    AV5                  .001 36              110              20    AV6                  .001
+--+                              ----.-    ----              4 -----        4.
ROW                  COL              PER LOCN                  INCH11
  +--------------+---------------
Tubes: 272                        Records: 607 21                ST Max to ET 10-0012 Steam Generator D Service-Induced Indications
 
SG - D              Service Induced Indications Wolf Creek 1                    RFO XVIISAP 20091001            11/03/2009 13:36:14
  .
  +- ----
  +---
ROW
          -+-
              ---+------------.------+
COL
              --- +----+-
PER LOCN                    INCHIJ
                                      - -+----------------+
27          8        11        AV1                .001 27          8        18        AV6                .001 29        10          12        AV1                .00 29        10          12        AV2                .001 29        10          25        AV5                .001 30        10          16      AV2                .001 30        10          26      AV5                .001 32        11          13      AV2                .001 32        11          19      AV6                .001 33        11          19      AV2                .00 33        11          18      AV5                .001 33        11          22      AV6                .001 31        12          10      AV5                .001
.        32 32 33 12 12 12 18 12 16 AV5 AV6 AV1
                                                            .001
                                                            .001
                                                            .00 33        12          20        AV2                .001 33        12          36      AV4                .001 33        12          31      AV5                .001 33        12          13      AV6                .001 34        12          12        AV6                .001 31        13          11        AV3                .001 31        13          10        AV5                .001 34        13          35        AV3                .001 34        13          17        AV4                .001 34        13          14        AV6                .001 32        14          25        AV4                .001 32        14          13        AV5                .001 32        14          15        AV6                .001 33        14          15 AV2                      .001 I      33-- 14              15..AV2... -....      ..- -
  . ROW COL PER LOCN
    ----------------------------+
INCH11 1                  ST Max
 
SG      - D        Service Induced Indications Wolf Creek 1              RFO XVIISAP 26691061                11/03/2609 13:36:14
              ------------------------------- +
* ROW COL ..PER LOCN                              INCH11
    - ---        +---  -    +-    -------------------
33      14      15    AV3                      .661 33      14      20    AV4                      .001 34      14      15    AV2                      .001 34      14      15    AV6                      .001 35      14      12    AV1                      .001 35      14      21    AV5                      .001 35      14      12    AV6                      .001 36      14      14    AV6                      .001 33      15      21    AV4                      .001 35      15      14    AV2                      .001 35      15      17    AV4                      .001 36      15      24    AV5                      .001 33      16        13    AV3                      .001
* 33      16        14    AV4                      .061 36      16        12    AV3                      .001 36      16      26    AV4                      .001 36      16      14    AV5                      .001 36      16      12    AV6                      .001 37      16      20    AV3                      .001 37      16      22    AV4                      .061 37      16      16    AV5                      .001 37      16      22    AV6                      .001 38        16      23    AV3                      .001 38        16      32    AV4                      .601 38        16      19    AV6                      .001 35        17      26    AV2                      .001 35      17        29    AV3                      .001 37      17        17    AV3                      .001 37      17        29    AV4                      .001 37      17        18    AV5                      .001
            ------------------------------.                    9
* ROW      COL      PER LOCN                      INCH11
      . . . +-..--. .-
  - - -.                  . .-  - --..                  ----
2                    ST Max
 
SG - D        Service Induced Indications Wolf Creek 1        RFO XVIISAP 20091001    11/03/2009 13:36:14
* ROW      COL  PER LOCN          INCH11
  .--- +.--    + ----  +-------------------
37      17    14 AV6              .001 38      17    14 AV1              .00 38      17    13 AV2              .001 38      17    14 AV4              .001 38      17    18 AV6              .001 34      18    14  AV4            .001 35      18    10  AV3            .00 35      18    14  AV5            .001 37      18    14 'AV1              .00 37      18    15 AV3              .001 37      18    13 AV4              .001 37      18    11 AV5              .001 38      18    15  AV4            .001 38      18    11  AV5            .001 38      18    13  AV6            .001 39      18    16  AV2            .001 39      18    19  AV3            .001 41      18    17  AV1            .001 41      18    19  AV3            .001 41      18    20  AV4            .001 41      18    17  AV5            .001 26      19    23    4H          -.591 30      19    14  AV5            .001 33      19    21  AV3            .001 37      19    15  AV1            .001 37      19    27  AV3            .001 37      19    16  AV4            .001 38      19    17  AV1            .001
---3738 --19      31 ---------
19 --27    AV3              0-1
                                      .001 38      19    15  AV4            .001 I ROW COL PER LOCN                  INCH11
..----------------------------. +
3            ST Max
 
SG - D        Service Induced Indications Wolf Creek 1              RFO XVIISAP 20091001            11/03/2009 13:36:14
+.+.--------------------------
IROW COL PER LOCN                                INCHIl
            +-------------------------+
38      19          16 AV5                      .001 38      19          16 AV6                      .001 39      19          31 AV2                      .I00 39      19          22 AV3                      .001 39      19          19 AV5                      .001 39      19          18 AV6                      .001 40      19          16        AV2              .001 140        19          16        AV4              ,00 40      19          12        AV5              .001 40      19          10        AV6              .001 32      29          10        AV3              .001 37      20          11        AV2              .001 37      20            7        AV3              .00-37      20          13        AV4              .001 1 39        20          26        AV2              ,001 39      20          34        AV3              .00 39      20          11        AV4              .001 40      20          34        AV4              .001 40      20          16        AV6              .001 31      21          13        TSH              . 061 37      21          20        AV2              .001 37      20          17        AV4              .001 38      21          19        AV2              .001 38      21          15        AV3              .001 138        21          21        AV4              .001 39      21          20        AV3              .001 39      21          18        AV5              .001 40      21          16        AV4              .001 40      21          18        AV5              .001 40      21          16        AV6              .001
---  *-        .+- - --      -.. - -..------
                            +-                            +
1  ROW    COL        PER LOCN                  INCHiI 4-----.  .--        .----  .-
                            -      --        .    -----
4                  ST Max
 
SG - D              Service Induced Indications Wolf Creek 1                    RFO XVIISAP 20091001          11/03/2009 13:36:14
..----                -    .--------
                                -
1 ROW          COL      PER LOCN                    INCH11
+----.----+            ---.----.          +------..+
38          19        16      AV5                .001 38          19        16      AV6                .001 39          19        31      AV2                .00 39          19        22      AV3                .001 39          19        19      AV5                .001 39          19        18      AV6                .001 1 40              19        16      AV2                .001 40          19        16      AV4                .001 40          19        12      AV5                .001 40          19        10      AV6                .00@
32          20        10      AV3                .001 37          20        11      AV2                .001 37          20          7    AV3                .001 37          20        13      AV4                .001 39          20      26      AV2                .00 I 39                20        34      AV3                .001 39          20        11      AV4                .001 40          20      20      AV4                .00 40          20        16      AV6                .001 31          21        13      TSH                .061 37          2 37          21        20      AV2                .001 37          21        17      AV4                .001 38          21        19      AV2                .001 I38            21        15      AV3                .001 38          21        21      AV4                .001 39          21        20      AV3                ,00 39          21        18      AV5                .001 40          21        16      AV4                .001 40          21        18      AV5                .001 40          21        16      AV6                .001
  - -    -+- -----    - -. -+- - - -.------                  +
I ROW          COL      PER LOCN                    INCH11
+ . . . .    - - --.- - - - -.-- - - -.-- - - -.. . . . .
4                    ST Max
 
SG - D                Service Induced Indications Wolf Creek 1                        RFO XVIISAP 20091001  1110312009 13:36:14 1 ROW          COL PER LOCN                    INCH11
            ~-------------------------------
41            21            15 AVI            .001 41            21            14 AV2            .001 41            21            23 AV5            .001 38            22            11 AV2            .00 38            22            17 AV3          .001 38            22            13 AV4          .001 38            22            15 AV6          .001 40            22            12  AV3        .001 41            22            22  AV2        .001 41            22            28  AV3        .00 41            22            28  AV5        .001 41            22            20  AV6        .001 42              22            13  AV4        .001 42            22            17  AV5        .001 42              22            13  AV6        .001 30              23            16  AV2        .001 35              23            20  AV3        .001 38              23            18  AV5        .001 38            23              17  AV6        .001 I                                    I 40            23              15  AV4        .001 40            23              25  AV5        .001 45            23              12  AV3        .001 39            24              17  AV2        .001 39            24              19  AV4        .001 42            24              19  AV2        .001 42            24              20  AV4        .001 42            24              11  AV6        .001 39            25              22  AV3        .00 39            25              15  AV5        .001
-- 39.. 24 . -19..-                .
                                    ---  4-      -
I ROW COL PER LOCN                              INCH11
  +-----------------------------.
5          ST Max
 
SG          D      Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001                  11/03/2009 13:36:14 1 ROW COL PER LOCN                                      INCH11 S 41-- 25 +--------- 18..AV3...
4-------                        -....                  ...
                                                        - -
4-------------------+
1 41              25    18 AV3                            .001 41        25    20 AV5                            .00 43        25    21  AV2                          .001 43        25    37  AV3                          .001 43        25    29  AV4                          .001 43        25    15  AV5                          .001 43        25    20  AV6                          .001 44        25    28  AV3                          .001 44        25    28  AV4                          .001 44        25    19  AV5                          .001 44        25    15  AV6                          .001 45        25    11  AV1                          .00 45        25    12  AV2                          .001 45        25    26  AV3                          .001 45        25    38  AV5                          .001 45        25    43  AV6                          .001 47        25    29  AV4                          .001 47        25    17  AV6                          .001 32        26    14  AV6                          .001 37        26    19  AV2                          .001 37        26    14  AV5                          .00 37      26      15  AV6                          .001 42      26      14  AV2                          .001 47      26      26  AV5                          .001 47      26      29  AV6                          .001 48      26      23  AV3                          .001 48      26      31  AV4                          .00 48      26      23  AV5                          .001 48      26      28  AV6                          .001 41      27      20  AV2                          .001 41      27      18  AV4                          .00 41      27      15  AV5                          .00
+-.          -- +--    ---      ------------------..
1 ROW          COL    PER LOCN                        INCH11
- ----.- ----.- ----.- ----.- ----......
6                        ST Max
 
SG      -  D    Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001                11/03/2009 13:36:14
-------------                  ------------------            +
1 ROW          COL        PER LOCN                    INCH11 43        27        18  AV2                        .001 43        27        33  AV3                        .001 43        27        14  AV4                        .001 43        27        21  AV5                        .001 43      27        20  AV6                        .001 44        27        13  AV4                        .00 44      27        11  AV5                        .001 45      27        12  AV4                        .001 45      27        11  AV5                        .001 47      27        15  AV5                        .001 47      27        15  AV6                        .001 37      28        21  AV6                        .001 42      28        27  AV2                        .00 42      28        21  AV3                        .001 42      28        17  AV4                        .001 42      28        22  AV6                        .001 45        28        26  AV2                        .001 45        28        25  AV3                        .00 45        28        17  AV4                        .001 45        28        36  AV5                        .001 45        28        33  AV6                        .001 46        28        26  AV5                        .001 46        28        22  AV6                        .001 47        28        24  AV2                        .001 47        28        24  AV3                        .001 47        28        35  AV5                      ,00 47        28        27  AV6                        .001 48        28        31  AV5                      .001 48        28        25  AV6                        .00 1    29          5  FBC                    -. 331 1 ROW          COL      PER LOCN                    INCH11
..-- -+----      + ---.              +-------------------
7                    ST Max
 
SG - D                Service Induced Indications Wolf Creek 1                          RFO XVIISAP 20091001                    11/03/2009 13:36:14 1 ROW            COL          PER LOCN                              INCH11
    ---        4- -  ----4-----4-------------------+
1 44                29            19          AV3                      .001 46          29            18          AV4                      .I01 46          29            15          AV5                      .001 48        29            13          AV6                      .001 49        29            41            AV2                      .00 49        29            19          AV3                      .001 49        29            40            AV4                      .001 49        29            23          AV5                      .001 49        29            26          AV6                      .001 50        29            12          AV4                      .001 50        29            18          AV5                      .001 1      30            14          FBC                      .301 42        30            26            AV2                      .00 42        30            30            AV3                      .001 42          30            22            AV5                      .001 43          30            16            AV2                      .001 43          30            24            AV5                      .001 46          30            28            AV3                    .001 49        30            26            AV1                    .001 49          30            41            AV2                    .00 49          30            43          AV3                      .001 49          30            27          AV4                      .001 49          30            28          AV5                      .001 49          30            31          AV6                      .001 50          30            36          AV6                      .001 1      31              9          FBC                    .301 1      31              2          FBH                  -. 381 1      31              3          FBH                    .111 46          31            17          AV1                      .00 46          31            25          AV2                      .001 4------------                            4------------------------+
I ROW              COL        PER LOCN                              INCH11
-------------                                  ------------------
8                              ST Max
 
SG - D        Service Induced Indications Wolf Creek 1          RFO XVIISAP 20091001      11/03/2009 13:36:14
.      +--------+----+ -------------------
ROW COL PER LOCN                    INCH11 46    31      35  AV3                .00 46    31      45  AV4                .001 46    31      42  AV5                .001 47    31      18  AV2                .001 47    31      14  AV3                .001 47    31      16  AV4                .00 47    31      37  AV5                .00 49    31      21  AV3                .001 49    31      11  AV4                .00 49    31      24  AV5              .00 49    31      18  AV6              .00 50    31      23  AV4              .00 50    31      29  AV5              .00 50    31      12  AV6              .00 1    32      5  FBC            -.311
. 1 1    32 32 3
4 FBH FBH
                                            -. 381
                                              .331 32    32      23  AV3              .00 41      32      21  AV3                eel 41      32      23  AV4              .00 47      32      31  AV4              .00 47      32      37  AV5              .00 47      32      14  AV6              .00 49      32      20  AV1              .00 49      32      33  AV3              .00 49    32      27  AV4              .00 49    32      22  AV5              .001 49    32      24  AV6              .001 50    32      28  AVM              .00 50    32      33  AV2              .00 50    32      26  AV3              .00 50    32      35  AV4              .00 50    32      28  AV5              .001 I ROW      COL      PER LOCN            INCH11
  - - - - -. - - -- -  --.-  -  -- - - -  -----
9                ST Max
 
wqý-    r-1%rTV-w4w,,jý -14" ", 7 SG - D              Service Induced Indications Wolf Creek 1                RFO XVII.SAP 20091001        11/03/2009 13:36:14 1 ROW            COL PER LOCN                    INCH11
                ~-------------------------------.
1        50        32    14 AV6                    .001 1      33        7  FBC              -. 331 1      33    10    FBC                .301 1      33        3  FBH              -.401 1      33        3  FBH                .371 37        33    22    AV2                .001 37        33    26    AV3                .001 37        33    10    AV4                .001 47        33    14    AV2                .00 47        33    13    AV3                .001 47        33    24    AV4                .001 47        33    22    AV5                .001 47        33    24    AV6                .001 48        33    19    AV2                .001 48        33    16    AV3                .001 48        33    19    AV4                .001 48        33    11    AV5                .001 52        33    27    AV6                .001 33        34    19    AV1                .00 33        34    18    AV2                .001 33        34    18    AV3                .001 33        34    19    AV4                .001 33        34    27    AV5                .001 35        34    22    AV3                .001 48        34    12    AVI                .001 48        34    38    AV2                .001 48        34    38    AV3                .001 48        34    23    AV4                .001 48        34    32    AV5                .001 48        34    12    AV6                .001 35        35    21    AV2                .00 35        35    21    AV4                .00I I      35.      35  .. 21..+    V..4 -        . 0
                ------------------------------          +
I ROW            COL    PER LOCN                INCH11
+----.----+----          -----. +..      -----          +
10                ST Max
 
SG - D          Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001            11/03/2009 13:36:14
  +-      -+---------------+
            +
  . ROW
    - -  -+--
COL
                -  -+-
PER LOCN
                          --    +- ---
                                              -----
                                            +-----+
INCH11
                                                            +
1 37          35        27      AV4                .001 37      35        27      AV5                .001 37      35        13      AV6                .001 39      35        13      AV2                .00 45      35        23      AV2                .001 45      35        22      AV3                .001 45      35        22      AV4                .001 45      35        24      AV5                .001 53      35        17      AV2                .001 53      35        37      AV3                .001 53      35        26      AV5                .001 54      35        18      AV5                .001 41      36        11      AV2                .001
.        43 43 36 36 17 15 AV2 AV4
                                                        .001
                                                        .001 43      36        12      AV5                .001 47      36        14      AV4                .00 47      36        11      AV6                .001 39      37        23      AV2                .001 39      37        27      AV3                .001 39      37        27      AV4                .001 39      37        23      AV5                .00I 41      37        26      AV3                .00 41      37        20      AV4                .001 42      37        18      AV4                .001 43      37        15      AV4                .00 43      37        17      AV5                .001 49      37        18      AV2                .001 49      37        28      AV3                .001 49      37        24      AV4                .001
      .        ----
I ROW        COL      PER LOCN                    INCH11
  +---      -+-      +--    -- ------------
                                +-                          +
11                    ST Max
 
SG - D                    Service Induced Indications Wolf Creek 1                            RFO XVIISAP 20091001        11/03/2009 13:36:14
. 1 ROW
    -  --
COL
            +--------------------------
PER LOCN            INCH11 1 49                37                17  AV5              .001 49            37                17  AV6              .001 50            37                17  AV6              .001 51            37                22  AV2              .001 54            37                16  AVM              .001 54            37                11  AV5              .001 40            38                15  AV5              .001 42            38                14  AV2              .001 42            38                16  AV4              .001 42            38                15  AV5              .001 43            38                19  AV2              .001 43            38                35  AV4              .001 43            38                31  AV5              .001 46            38                20  AV3              .001 46            38                16  AV4              .001 46            38                18  AV5              .001 49            38                12  AV3              .00 49            38                22  AV4              .001 49            38                14  AV5              .001 51            38                15  AV4              .001 51            38                14  AV5              .001 44            39                17  AV2              .00 44            39                18  AV4              .001 45            39                19  AV3              .001 46            39                16  AV2              .001 46            39                23  AV4              .00 46            39                21  AV5              .001 48            39                22 AVM                .00 48            39                23 AV2                .001
      ...-----------------------------
1 ROW COL PER LOCN                                        INCH11
  - --- -. ----.                    - ----  - - - -- - -- -- -- - --
12              ST Max
 
SG - D        Service Induced Indications Wolf Creek 1        RFO XVIISAP 20091001        11/03/2009 13:36:14
. ROW    COL    PER LOCN            INCH11 1 48      39    23    AV3              .001 1 48      39    38    AV4              .001 1 48      39    41    AV5              .001 48      39    25    AV6              .001 49      39    16    AV2              .001 49      39    18    AV3              .001 52      39    26    AV3              .001 52      39    38    AV4              .001 52      39    26    AV5              .001 38      40    30    AV2              .001 38      40    16    AV4              .001 38      40    17    AV5              .001 41      40    19    AV3              .001 41      40    19    AV4              .001 41      40    18    AV6              .081 O    39      41    18  AVI                .001 39      41    23  AV2                .00*
39      41    31    AV3              .001 39      41    30  AV4                .001 39      41    22  AV5                .001 42      41    21  AV2                .001 42      41    31  AV3                .001 42      41    24  AV4                .001 42      41    26  AV5                .001 42      41    23  AV6                .001 51      41    25  AV1                .00 51      41    25  AV2                .001 51      41    37  AV3                .001 25      42    13  AV2                .001 25      42    14  AV5              .001 37      42    14  AV3              .001 37      42    25  AV4              .001
          ------------------------------        +
1 ROW    COL    PER LOCN            INCH11
  + - - +- - - -    ---- -----  ----------...
13              ST Max
 
SG      -  D        Service Induced Indications Wolf Creek 1                      RFO XVIISAP 20091001                11/03/2009 13:36:14
    -.--.--.        .........-      ----------                      +
1 ROW          COL          PER LOCN                        INCH11
  .----    +----+--          --    +-----+          -------
1      41        42              14      AV4                    .001 43        42              11      AV5                    .001 45        42              15      AV2                    .001 47        42            21        AV4                    .00 47        42            29        AV5                    .001 47        42            17        AV6                  .001 41        43            36        AV2                    .001 41        43            35        AV3                  .001
      ,41        43            18        AV4                  .001 41        43            32        AV5                  .001 43        43            28        AV2                  .00 43        43            14        AV3                  .001 45        43            22        AV3                  .001 45        43            33        AV4                  .001 45        43            29        AV5                  .001 45        43            24        AV6                  .001 42        44            17        AV4                  ,00 42        44            13        AV5                  .001 43        44            21        AV2                  .001 43        44            33        AV3                  .001 43        44            19        AV5                  .001 43        44            20        AV6                  .001 33        45            15        AV4                  .001 44          45            13        AV5                  .001 46          45            17      AV3                    .00 46        45            17        AV4                  .001 46          45            16        AV6                  .001 51          45            22        AV4                  .001 44          46            12 AVi                          .001
            ~----------------------------+-
I ROW COL PER LOCN                                            INCH1I
  -..--      ..    -        -- -    --...    -------
14                        ST Max
 
                                                                      * :i a~
SG - D            Service Induced Indications Wolf Creek 1            RFO XVIISAP 20091001      11/03/2009 13:36:14
+-----------------------------
* ROW COL PER LOCN                        INCH11
  - --  +-- -------  +----.  +      .-----.    +
44        46    15    AV2            .001 44        46    20    AV5              .001 45        46    18    AV2              .001 45        46    16    AV3            .008 45        46    16    AV4              .001 45        46    18    AV5            .001 45        46    19    AV6            .001 41        47    26    AV2            .001 41        47    21    AV4            .001 41        47    14    AV5            .001 41        47    24    AV6            .001 50        47    12    AV2            .001 50        47    13    AV3            .001 50        47    13    AV4            .001 50        47    19    AV5            .001 50        47    14    AV6            .001 41        48    18    AV3            .001 44        48    24    AV5            .001 44        49    19    AV2            .001 44        49    15    AV4            .001 44        49    24    AV5            .001 44        49    13    AV6            .001 45        49    10    AV4            .00I 45        49    10    AV5            .00@
49        49    17    AV2            .001 58        49    19    AV1            .001 40        50    30    AV3            .001 40        50    30    AV4            .001 40        50    30    AV5            .001 48        50    17    AVI            .001 48        50    36    AV3            .001
- -----  ---      ------- -- -- - .. ......
I ROW COL PER LOCN                        INCH1I
---------------------------- +--
15            ST Max
 
SG    -  D        Service Induced Indications Wolf Creek 1                RFO XVIISAP 20091001            11/03/2009 13:36:14
  -------------------------------+
* ROW COL PER LOCN                                  INCH11
    .-- --  +------      --.      .-------------------      +
1 48              50      35  AV4                    .001 1 48            50      36  AV5                    .001 1 48            50      11  AV6                    .001 51        50      15  AVM                    .001 52          50      14  AV2                    .001 52          50      18  AV3                    .001 52        50      13  AV4                    .001 52          50      16  AV5                    .001 50          51      14  AV1                    .001 50        51      30  AV2                    .001 50        51      23  AV4                    .001 50        51      19  AV5                    .001 50          51      10  AV6                    .001 41          52      19  AV2                    .001 41          52      15  AV3                    .001
:01      41          52      19  AV4                    .001 44          52      18  AV2                    .001 52          52      26  AV2                    .00 52          52      36  AV3                    .00I 59          52      11  AVM                    .001 59          52      11  AV5                    .001 25          53      17  AV2                    .001 25          53      16  AV5                    .00I 30          53      10  AV2                    .001 30          53      11  AV5                    .00 36          53      17  AV2                    .001 36          53      17  AV5                    .001 37          53      15  AV4                    .001 37          53      21  AV5                    .001 39          53      13  AV3                    .001
              ---------------------------------              +
I ROW          COL    PER LOCN                    INCH11
  +----+-------------...          .-----                    +
16                  ST Max
 
SG - D              Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001            11/03/2009 13:36:14 1 ROW          COL        PER LOCN                    INCHI1
  .---    +---      --      -+-------------------+
33          54      16      AV2                  .001 35          54      17      AV3                  .00 35          54      19      AV4                  .00 35        54      21      AV5                  .001 38        54      23      AV3                  .001 38        54      29      AV4                  .00 38        54      29      AV5                  .001 50        54      12      AV2                  .001 50        54      14      AV4                  .001 50        54      18      AV6                  .00 51        54      14      AV2                  .001 51        54      16      AV3                  .001 51        54      25      AV4                  .001 51        54      17      AV5                  .001 I      25        55      16      AV1                  .001 25        55      16      AV2                  .001 39        55      14      AV1                  .001 39        55      11      AV2                  .001 I      39        55      17      AV4                  .001 39        55      11      AV5                  .00 39        55      11      AV6                  .001 41        55      16      AV2                  .001 41        55      29      AV3                  .001 41          55      29      AV4                  .001 41        55      21      AV5                  .001 41        55      16      AV6                  .001 45        55      17      AV2                  .001 45          55      14      AV3                  .001 45          55      25      AV4                  .001 45          55      10      AV5                  .001 45        55      11      AV6                  .001 48          55      21 AV3                        .001 I      45.        55 +    25..+ ....
AV4.                  01 I ROW          COL      PER LOCN                    INCHiI
- -....-    -....-      - -...- --. ..- --.. ......
17                      ST Max
 
SG - D            Service Induced Indications Wolf Creek 1              RFO XVIISAP 20091001              11/03/2009 13:36:14
+.-    -. --- -4.  + ---  +I......  +---------------+
I ROW COL PER LOCN                              INCH11
+
+ ....------ ....
              -      + ....----------
4----    4-----4-------------------+
I+
52        55      18        AV2              .001 34        56      39        AV2              .001 34        56      24        AV3              .001 34        56      10        AV4              .001 34        56      35        AV5              .001 44          56      25        AV6              .001 45        56      16        AVI              .001 45        56      37        AV2              .001 45        56      31        AV3              .001 45          56      34        AV4            .001 45        56      31        AV5            .001 45          56      18      AV6              .001 50        56        12      AV1              .00 50        56        16      AV2              .001 50        56        30      AV3              .001 I    50        56        36      AV4              .001 50        56        24      AV5              .001 50        57        16      AV2              .001 50        57        12      AV3              .001 35        58        10      AV2              .001 36        58        10      AV4              .001 41        58        13      AV2              .001 41        58        19      AV4              .00 41        58        23      AV2              .001 50        58        20      AV3              .001 50        58        20      AV4              .00f 50        58        15      AV5              .001 50        58        12 AV6                    .00i 41        59        47 AV2                    .00 41        59        22 AV3                    .001 41        59        17 AV4                    .001 I    41..      59        17..AV....4÷.            .0 1 ROW        COL PER LOCN                      INCH11
  .        ..----------------------------
18                ST Max
 
SG      - D      Service Induced Indications Wolf Creek 1            RFO XVIISAP 20091001      11/03/2009 13:36:14 1 ROW      COL    PER LOCN            INCH11 1 41          59    20        AV5          .001 50      59    25        AV2          .001 50      59    23        AV4          .001 50      59    17        AV5          .001 50    59    14        AV6          .001 35    60      14        AV3          .001 35    60      26        AV5          .001 40    60      15        AV4          .001 48    60      15        AV1          .I0 48    60      17        AV2          .001 48    60      42        AV3          .001 48    60      31        AV4          .001 48    60      28        AV5          .001 48    60      27        AV6          .001 33    61      17        AV2          .001 33    61      18        AV3          .001 35    61      12        AV2          .001 35    61      20        AV3          .001 44    61      13        AV2          .001 44    61      34        AV3          .001 44    61      21        AV4          .001 44    61      12        AV6          .001 44    61      29          5H      -. 531 55    62      36        AV1          .001 55    62      33        AV2          .001 55    62      18        AV3          .001 40    63      17        AV2          .001 41    63      10        AV5          .001 33    64      15 AV2                  .001 33    64      14 AV3                  .001 33    64      20 AV4                  .001
.  -. .-
ROW
------
          + -... --...-+-... -+....
COL PER LOCN
              ----  ------------------
                                          ... +
INCH11
                                                +
19              ST Max
 
SG - 0              Service Induced Indications Wolf Creek 1                    RFO XVIISAP 20091001        11103/2009 13:36:14 ROW        COL PER LOCN                    INCHIJ
              ------------------------------                +
33        64          14 AV5                  .001 38        64          13 AV2                  .00 38        64          14 AV3                  .001 41        64          21        AV3          .001 41        64          19        AV5          .001 41        64          15        AV5          .331 44        64          11        AV2          .001 47        64          15        AV2          .001 15        65          27            5H        .001 40        65          10        AV2          .001 45        65          11        AV2          .001 31        66          17        AV2          .00
* 31        66          13        AV6          .001 33        66          12        AV2          .001 33        66          11        AV3          .001 41        66          12        AV1          .001 41        66          23        AV2          .001 41        66          25        AV3          .001 41        66          27        AV4          .001 41        66          22        AV5          .001 41        66          31        AV6          .001 4        6I 44        66          14        AV2          .001 I44          66          16        AV3          .001 I                                          I 44        67          18        AV2          ,001 44        67          20        AV3          .001 44        67          18        AV4          .001 49        67          28        AV2          .00 49        67          51        AV3          .001 49        67          51        AV4          .001
      +  .÷.  .  .        .    .+    .    .    ....  ...
I ROW          COL        PER LOCN            INCH11
  +----+              -+-----  ---------------.              +
20            ST Max
 
SG - D          Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001          11/03/2009 13:36:14
  .------------------------------
* ROW COL PER LOCN                                INCH11
  -  -.-- --  -+-----------------                        +
49      67          42      AV5              .001 49      67          26      AV6              .001 34      68          16      AV2              .00 40      68          16      AV2              .001 45      68          20      AV2              .001 46      68          28      AV2              .00I 46      68          20      AV3            .00!
50      68          16      AV4              .001 31      69          10      AV1            .001 31      69          11      AV2            .001 31      69          14      AV5              .001 34      69          16      AV2            .00 34      69          14      AV3            .001 36      69          11      AV3            .001 52      69        .18        AV1            .001 30      70          12      AV1            .001 30      70          12      AV2            .001 33      70          11      AV2            .00 39      70          11      AV2            .001 44      70          18      AV1            .001 44      70          24        AV2            .001 44      70          15      AV3            .001 44      70          26        AV5            .001 44      70          25        AV6            .001 45      70          16        AV2            .001 46      70          30        AV2            .001 46      70          24        AV3            .001
- -----    -----      -----        -----    --------    -
I ROW        COL        PER LOCN                INCH1I
+ ..  ..  -- --. - - --.. ..- ÷-...    .-
                                          ÷---
21                ST Max
 
SG - D                Service Induced Indications Wolf Creek 1                      RFO XVIISAP 20091001      11/83/2009 13:36:14
. ---.---
ROW        COL
                    -----
+----+----.----+--.----------
                                -----
PER LOCN
                                          -+-----+
INCH11 50            70        27      AV2            .001 50            70        25      AV3            .001 55            70        14      AV3            .00I 57            70        21      AV5            .001 58            70        18      AV2            .001 36            71        36      AV              .00.
36            71        28      AV2            .001 36            71        24      AV3            .001 36            71        22      AV4            .001 36            71        29      AV5            .001 36            71        15      AV6            .001 24          72        16      AV2            .001 I 32  32 72 72 29 15 AVI AV2
                                                      .00
                                                      .001 32          72        18      AV5            .001 34          72        13      AV2            .001 36          73        17      AV2            .001 36          73        11      AV4            .00I 36          73        21      AV5            .001 58          73        13      AV2            .001 39          74        17      AV3            .001 39          74        13      AV4            .001 45          74        17      AV1            .001 45          74        15      AV2            .001 48          74        29      AV2            .001 48          74        15      AV3            .001 39          75        17      AV2            .001 39          75        18      AV3            .001
  ...        ---.--        ----- --.---- -.------        +
I ROW COL PER LOCN                                  INCH11
  ..------------------------------
22              ST Max
 
SG - D                      Service Induced Indications Wolf Creek 1                            RFO XVIISAP 20091001                  11/03/2e09 13:36:14
  .I -
      -  ----
ROW CaL
        --------------
                        -----    --------
PER.LOCN 4.---
                                                          ---------
                                                          -4.-----+-
INCH11
                                                                              +
1 39                      75        17        AV4                    .00 39              75        17        AV5                    .001 44              75        17        AV1                    .ee 44              75      23        AV2                    .00 44              75        16        AV3                    .001 44              75      21        AV4                    .001 44                75        16        AV5                    .00 36              76        18        AV1                    .001 36              76        19        AV2                    .001 52                76      16        AV1                      eel 52              76        16        AV2                    .001 52              76        14        AV3                    .00 57              76        28        AV4                    .00 57                76        37        AV5                    .00
.          44 44 39 77 77 78 23 11 29 AV3 AV4 AV3
                                                                          .Ae
                                                                          .001
                                                                        .Il 39              78        18        AV4                    .001 39              78        21        AV5                    .001 41              78        20        AV2                    .001 46              78        20          AV2                    .00 50              78        16        AV1                    .e0 50              78        20          AV2                    .001 50              78        31          AV3                    .001 50              78        17          AV4                    .001 28              79        16          AV2                    .001 28              79        15          AV5                    .00 33              79        18          AV5                    .001 39              79        23          AV2                    .00 1 ROW                COL      PER LOCN                            INCH11
  +----+----+------                          ---..-----..                    +
23                        ST Max
 
SG - D                Service Induced Indications Wolf Creek 1                      RFO XVIISAP 20091001                          11/03/2009 13:36:14
    ....------------...                                  .---------        ÷ 1 ROW              COL    PER LOCN                                    INCH11
  - --    +---------            ---------------
1 42                79      23              AV3                        .001 36            80      13              AV3                        .001 36            80      16              AV4                        .001 37            80      11              AV2                        .001 39            80      25              AV2                        .001 39            80      17              AV4                        .001 50            80      16              AV2                        .001 50            80      14              AV3                        .001 50            80      14              AV4                        .001 56            80      15              AV4                        .001 37            81      13              AV2                        .001 37            81      20              AV3                        .001 37            81      15              AV4                        .001 43            81      13              AV2                        .001 43            81    27              AV3                        .001 43            81      12              AV4                        .001 43            81      19              AV5                        .001 45            81    37              AV2                        .001 45            81    51              AV3                        .001 45            81    44              AV4                        .001 45            81    21              AV5                        .001 47            81    24              AV3                        .001 49            81    23              AV2                        .001 51            81    38              AV2                        .00I 51            81    17              AV3                        .001 51            81    23              AV4                        .001 51            81    22              AV5                        .001 51            81    10              AV6                        .001 24            82    16 AV2                                      .001 24            82    15 AV6                                      .001
          ~----------------------------.9.
I ROW COL PER LOCN                                                    INCH11
  - --.  ----      +-. . ....---                ....-----
24                              ST Max
 
SG - D              Service Induced Indications Wolf Creek 1                        RFO XVIISAP 20091001          1110312009 13:36:14 1 ROW          COL PER LOCN                            INCH11
+4- ...--------      + .. + --. ---.. ...
                .. +--------------------                    . I+
43    82            19        AV2            .001 43    82            24        AV4            .001 45    82            16        AV2            .001 45    82            38        AV3            .001 45    82            15        AV5          .001 45    82            11        AV6          .001 49    82          21        AV2            .001 39    83            31        AV3            .001 39    83            25        AV4            .001 39    83            15        AV5            .001 39    83            15        AV6            .001 40    83            25        AV3            .001 44    83            17        AV2            .00 48    83            15        AV2            .001 48    83            19        AV4            .001 20    84            22        AV6            .001 32    84            17        AV3            .00 32    84            16        AV6            .001 41    84            17        AVM            .001 41    84            25        AV3            .001 41    84            21        AV4            .001 41    84            21        AV5            .001 46    84            17        AV2            .00 46    84            35        AV3            .001 46    84            23        AV4            .001 24    85            21        AV6            .001 35    85            15        AV3            .001 35    85            18        AV4            .001 I ROW          COL        PER LOCN                  INCH11
+ - - - -. - - - -- - - - -              - - --.- -- ------
25              ST Max
 
SG - D                          Service Induced Indications Wolf Creek 1                              RFO XVIISAP 20091001                11/03/2009 13:36:14
  -  ----                --        --    1-
                                            --    --- -    --------
1 ROW                    COL          PER LOCN                        INCH11
+----+----------+--------------
1 46                          85        17      AV3                    .001 46                  85        20      AV4                    .001 49                  85        24      AV2                    .00 49                  85        16      AV3                    .001 49                  85        21      AV4                    .001 49                  85        20      AV5                    .001 50                  85        28      AV4                    .001 50                  85        25      AV5                    .001 50                  85          19      AV6                    .001 26                  86        18      AV5                    .001 40                  86        23      AV3                    .001 41                  86        21      AV4                    .001 28                  87          17      AV2                    .001 30                  87          16      AV2                    .001 36                  87          18      AV1                    .001 38                  87          15      AV3                    .001 40                  87          19      AV1                    .001 40                  87          22      AV2                    .001 40                  87          22      AV3                    .001 40                  87          34      AV4                    .001 40                  87          15      AV5                    .001 47                  87          14      AV1                    .001 50                  87          20      AU                      .00I 50                  87          21      AV5                    .001 20                  88          22      AV1                    .001 35                  88          15      AV3                    .001 38                  88          17 AV2                          .001
                  ~------------------------------
I ROW COL PER LOCN                                                    INCH11
----.----                      +----+--      --.    +------..+
26                        ST Max
 
SG - D        Service Induced Indications Wolf Creek 1        RFO XVIISAP 20091001          11/03/2009 13:36:14
+ -- +----+---------+----------------
1 ROW COL PER LOCN                    INCH11
+....+      -- -          - +-
                      +....---  ---------.
1 38        88    18 AV3                  .001 43      88    15    AVM                .001 45      88    12    AV2                .00 45      88    16    AV3                .001 45      88    20    AV4                .001 45      88    32    AV5                .001 49      88    20    AV3                .001 49    88    21    AV4                .001
    '50    88    21    AV2                .001 50      88    16    AV3                .001 50      88    17    AV4                .001 50    88    21    AV5                .001 53    88    12    AV2                .001 36    89    18    AV3                .001 38    89    25    AV3                .001 38    89    28    AV4                .001 38    89    23    AV5                .001 39    89    18    AV2                .001 47    89    13      MV              .001 50    89    22    AV3                .001 50    89    16    AV4                .001 50    89    17    AV5                .001 1    90      4    FBC            -. 331 1    90      8    FBC                .361
÷ ..36 0    90 89    22 16    AV3 AV4. .    .... .. .001
                                              .1 36    90    17    AV4                .001 36    90    22    AV6                .001 39    90    20    AVM                .001 39    90    21    AV2                .001 ROW 1      COL  PER LOCN              INCH11
  -    1... 90 .... 8...-+ B÷ C      .        36I 27            ST Max
 
SG - 0      Service Induced Indications Wolf Creek 1      RFO XVIISAP 20091001      11/03/2009 13:36:14
  .----------------------------- +
1 ROW COL PER LOCN                INCH11 39    90    14  AV5              .001 45    90    20  AV3              .00f 53    90    24  AV4              .001 53    90    21  AV5              .001 53    90    24  AV6              .001 1    91    7  FBC          -. 361 1    91    5  FBH              .001 32    91    19  AV5              .001 36    91    18  AV2              .00 36    91    17  AV4              .001 37    91    13  AV3              .001 49    91    42    AV2              .00 49    91    15  AV3              .001 49    91    19  AV4              .001 49    91    24    AV5              .001 I    1    92      9  FBC          -. 361 19    92    16  AV6              .001 40    92    18  AV1              .00 40    92    24    AV3              .001 40    92    18  AV5              .001 43    92    13  AV2              .001 43    92    28  AV3              .001 43    92    14  AV4              .00 43    92    15  AV5              .001 45    92    15  AV3              .00 45    92    20    AV4              .001 45    92    23  AV5              .001 49    92    25    AV2              .001 49    92    13  AV3              .001 I  49. 92    13    .
AV3.    .... ..    .1
      ~----------------------------+-
1 ROW COL PER LOCN              INCH11
----------------------------- +
28          ST Max
 
:--!1 SG  -  0      Service Induced Indications Wolf Creek 1              RFO XVIISAP 20091001          11/03/2009 13:36:14 1 ROW        COL      PER LOCN            INCH11 1 49          92        23    AV4            .001 1 49          92        17    AV5            .001 1      93          9    FBC            .301 45        93        14    AV3            .001 45        93        22    AV4            .001 45        93        22    AV5            .001 45        93        16    AV6            .001 1      94          2    FBC            .251 39        94        15    AV3            .001 41        94        32    AV2            .00 41        94          29    AV3            .001 41        94          24    AV4            .001 41        94          21    AV5            .001 41        94          11    AV6            .001 43        94          29    AV2            .001 43        94          16    AV3            .001 43        94          18    AV4            .001 43        94          23    AV5            .001 44        94          16    AV3            .00 44        94          17    AV4            .001 35        95          10    AV1            .001 35        95          13    AV5            .001 38        95          26    AV2            .00@
40        95          18    AV5            .001 40        95        25    AV6            .001 41        95        20    AV2            .00 41        95        15    AV4            .001 41        95        23    AV5            .001 44        95          19    AV2            .001 44        95        27    AV3            .001
                                            . . .
- - - - - - - -. - - --. - - - -. - - - - --.          +
1 ROW      COL      PER LOCN            INCH11
.    .  . -+.  ..----    --  -. .  .    .------.-.
29            ST Max
 
                                                                        * -*r,- * ~* - .1z
                                                                                        *= -. -. .-
SG    -    D        Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001                11/03/2009 13:36:14
                      ---    ----        -+    -----
1 ROW          COL      PER LOCN                    INCH11
+- ----------------                          + -----            +
I45                95      11        AV                  .00 1 45              95      17        AV2                  .001 45          95      17        AV3                  .001 45          95      27        AV4                  .001 45          95      33        AV5                  .001 45          95      21        AV6                  .001 45          95      18      AV2                  .00 41          96      18      AV2                  .001 41            96      33      AV3                  .001 41            96      15      AV5                  .001 I44            96      22      AV2                  .001 44            96      31      AV3                  .001 44            96      17      AV4                  .001 44            96      18      AV6                  .001 45            96      18      AV2                  .00 45            96      28      AV5                  .001 27            97      17      TSH                -. 721 38            97      18      AV4                  .00 38            97      16      AV5                  .001 40            97      18      AV3                  .001 40            97      20      AV4                  .001 41            97      22      AV3                  .001 41            97      33      AV4                  .001 46          97      25      AV3                  .001 40          98      26      AV2                  .001 40          98      27      AV3                  .001 40          98      21      AV4                  .001 40            98      18      AV6                  .001 38          99      20      AV2                  .00 38          99      19      AV3                  .001 41          99      18 AV2                        .001
            ~----------------------------+-
I ROW COL PER LOCN                                    INCH11
--  --    +- ----    ---    +------------                  +
30                      ST Max
 
SG      - D      Service Induced Indications Wolf Creek 1            RFO XVIISAP 20091001                11/03/2009 13:36:14
  . ROW      COL    PER LOCN                      INCHI1
                                .-----------------------------
                                                            +
1 41          99      16 AV3                        .001 41      99      12 AV4                        .001 41      99      15 AV6                        .001 43      99      12      AV5                  .001 34    100      13      AV3                  .001 38    100      20      AV2                  .001 38    100      19      AV3                  .001 38    100      15      AV4                  .001 38    100      21      AV5                  .001 40    100      21      AV2                  .001 40    100      17      AV6                  .001 41    100      29      AV2                  .00 41    100      25      AV3                  .001 41    100      25      AV4                  .001 41    100      19      AV5                  .001 42    100      19      AV3                  .001 42    100      30      AV4                  .001 36    101      17      AV2                  .001 38    101      29      AV3                  .00 38    101      24      AV4                  .001 38    101      16      AV5                  .001 38    102      14      AV3                  .001 40    102      20      AV2                  .00 40    102      36      AV3                  .001 40    102      35      AV4                  .001 26    103      15    AV5                    .001 34    103      11    AV3                    .001 34    103      10    AV4                    .001 34    103      17    AV6                    .001
.  ....    .... + ....          ---....--- +I I ROW        COL    PER LOCN                      INCH11
    ---..      --  --      ----    --------------        +
31                    ST Max
 
SG      -  D      Service Induced Indications Wolf Creek 1                    RFO XVIISAP 20091001                  11/03/2009 13:36:14
      ...-    +~ -~....        -- 4.-. - ..        ---------
1 ROW            COL      PER LOCN                          INCH11 1 36            103        12      AV3                          .001 36      103        17      AV4                        .001 38      103        11      AV2                        .00 38      103        18      AV3                        .001 38      103        34      AV4                        .001 38      103        25      AV5                        .001 40      103        20      AV2                        .001 40      103        30      AV3                        .00 40      103        27      AV4                        .001 40      103        14      AV5                        .001 40      103        17      AV6                        .001 43      103        13      AV4                        .001 32      104        18      AV5                        .001 34      104        17      AV3                        .001 I 35    34      104        15    AV4 AV4-                        .001 35      104        16    AV5                          .001 38      104        20      AV3                        .001 40      104        39    AV2                          .001 40      104        29    AV3                          .001 40      104        17    AV4                          .001 40      104        24    AV5                          .001 40      104        17    AV6                          .001 30      105        13    AV2                          .001 33      105        11    AV3                          .001 33      105        14    AV5                          .001 35      105        13    AV6                          .001 38      105        33    AV3                          .001 38      105        22    AV4                          .001 38      105        10    AV6                          .001
. l ROW
    .---
COL
              .---    +----
PER LOCN
                                  +      .-------------------
INCH1I
                                                                      +
32                        ST Max
 
SG - D                Service Induced Indications Wolf Creek 1                    RFO XVIISAP 20091001              11/03/2009 13:36:14
  ..-- -    - - -    ..---        ..-------------------
1 ROW            COL      PER LOCN                  INCH11
    - -  ---    -----      -------      - --------              +
34      106        15        AV4                .001 34      106        17        AV6                .001 34        106        17        AV6                .001 35        106        21      AV2                .001 35        106        19      AV3                .001 35        106        15      AV4                .001 35      106        17      AV6                .001 36        106        16      AV4                .00 36        106        15      AV5                .001 40      106          13      AV4                .001 35      107          23      AV3                .001 35      107          19      AV4                .00 35      107          16      AV5                .001 35      107        13        AV6                .00 36      107        19        AV4                .001 36      107        18        AV5                .001 35      108        29        AV4                .001 35      108        15        AV5                .00 35      108        17        AV6                .001 37      108        14        AV6                .001 38      108        16        AV6                .001 28      109        13        AV5                .001 32      109        13        AV5                .001 32      109        14        AV6                .001 33      109        16        AV3                .001 33      109        16        AV4                .001 33      109        22        AV5                .001 34      109        14        AV2                .001 34      109        10        AV4                .001
  -.. . - -.. . --.        ..      - ---. ------.    . ..  +
I ROW          COL        PER LOCN                  INCH11
  ....--- ....--                *-        -+------
33                    ST Max
 
SG      -    D    Service Induced Indications Wolf Creek 1                  RFO XVIISAP 20091001  11/03/2009 13:36:14
* ROW          COL PER LOCN              INCH11
  - 34..109 ....12..        - -...      .....
34 109              12 AV5            .001 34 109              14 AV6            .00 36      109        12      AV6      .001 29      110        14      AV5      .001 32      110        14      AV5      .001 35      110        16      AV3      .00 35      110        30      AV4      .001 35      110        19      AV6      .001 29      111        14      AV2      .00 30      111        14      AV2      .001 30      111        16      AV6      .001 32      111        14      AV6      .001 27      113        18      AV2      .001 30      113        21      AV5      .001 24      115        20      AVI      .001 26      115        13      AV1      .001 27      115        11      AV1      .001 27      115        16      AV6      .001 22      116        18      AV6      .001 21      118        10 AVi            .001
              ~-----------------------------+
I ROW COL PER LOCN                        INCH11
  -....--.-----    +----.----+-----
Tubes: 416 Records: 1005 34        ST Max}}