| title = Forwards LERs 79-019/03L-0,79-027/03L-0 & 79-028/03L-0 | | title = Forwards LERs 79-019/03L-0,79-027/03L-0 & 79-028/03L-0 | ||
| release date = 05/31/2018 | |||
| package contents = {{Adams package content | | package contents = {{Adams package content | ||
| number = ML17317B187 | | number = ML17317B187 | ||
| issue date = 05/09/1979 | | issue date = 05/09/1979 | ||
| title = | | title = LER 79-028/03L-0 on 790410:torque Required to Open Lower Ice Condenser Inlet Door 3-R Exceeded Tech Specs.Caused by Sheet Metal Screws Loose at Bottom of Door.Door Frame Edge Depressed | ||
| author name = | | author name = Beilman T | ||
| author affiliation = INDIANA MICHIGAN POWER CO. | | author affiliation = INDIANA MICHIGAN POWER CO. | ||
| addressee name = | | addressee name = | ||
Line 20: | Line 21: | ||
| number = ML17317B186 | | number = ML17317B186 | ||
| issue date = 05/09/1979 | | issue date = 05/09/1979 | ||
| title = | | title = LER 79-027/03L-0 on 790416:during Refueling W/Emergency Diesel Generator AB inoperable,600 Volt Bus 11D Made Inoperable by Removal of Normal Feed Breaker T1112 for Cleaning.Caused by Personnel Error.Operators Reinstructed | ||
| author name = | | author name = Lease R | ||
| author affiliation = INDIANA MICHIGAN POWER CO. | | author affiliation = INDIANA MICHIGAN POWER CO. | ||
| addressee name = | | addressee name = | ||
Line 35: | Line 36: | ||
| number = ML17317B185 | | number = ML17317B185 | ||
| issue date = 05/09/1979 | | issue date = 05/09/1979 | ||
| title = | | title = LER 79-019/03L-0 on 790413:while Performing Hydraulic Snubber Surveillance Insp,Snubbers GBD-S573 & GBD-S574 Found W/Drained Reserviors.Caused by Loose Pipe Unions Between Snubbers & Remote Reservoirs.Snubbers Replaced | ||
| author name = | | author name = Brown M | ||
| author affiliation = INDIANA MICHIGAN POWER CO. | | author affiliation = INDIANA MICHIGAN POWER CO. | ||
| addressee name = | | addressee name = | ||
Line 51: | Line 52: | ||
| issue date = 05/09/1979 | | issue date = 05/09/1979 | ||
| title = Forwards LERs 79-019/03L-0,79-027/03L-0 & 79-028/03L-0 | | title = Forwards LERs 79-019/03L-0,79-027/03L-0 & 79-028/03L-0 | ||
| author name = | | author name = Shaller D | ||
| author affiliation = INDIANA MICHIGAN POWER CO. | | author affiliation = INDIANA MICHIGAN POWER CO. | ||
| addressee name = KEPPLER J G | | addressee name = KEPPLER J G |
Latest revision as of 08:50, 7 March 2020
Date released: 05/31/2018 | Download: ML17317B184 |
---|---|
ML17317B187 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 05/09/1979 |
From: | Beilman T INDIANA MICHIGAN POWER CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML17317B187 (2) | |
ML17317B186 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 05/09/1979 |
From: | Lease R INDIANA MICHIGAN POWER CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML17317B186 (2) | |
ML17317B185 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 05/09/1979 |
From: | Michael Brown INDIANA MICHIGAN POWER CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML17317B185 (2) | |
ML17317B182 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 05/09/1979 |
From: | Shaller D INDIANA MICHIGAN POWER CO. |
To: | KEPPLER J G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML17317B182 (1) | |