ML17252A246: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(9 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17252A246
| number = ML17252A246
| issue date = 11/04/1976
| issue date = 11/04/1976
| title = Dresden Unit 3, Letter Submitting Reportable Occurrence Number 050-249/1976-23 in Accordance with Technical Specifications, Section 6.6.B
| title = Letter Submitting Reportable Occurrence Number 050-249/1976-23 in Accordance with Technical Specifications, Section 6.6.B
| author name = Stephenson B B
| author name = Stephenson B
| author affiliation = Commonwealth Edison Co
| author affiliation = Commonwealth Edison Co
| addressee name = Keppler J G
| addressee name = Keppler J
| addressee affiliation = NRC/RGN-III
| addressee affiliation = NRC/RGN-III
| docket = 05000237, 05000249
| docket = 05000237, 05000249
Line 14: Line 14:
| page count = 3
| page count = 3
}}
}}
See also: [[followed by::IR 05000249/2019076]]


=Text=
=Text=
{{#Wiki_filter:.**. Comrnonv.h Edison * Dresde,1 Nuclear Power Station R.R. #i Morris, Illinois 60450 Telephone 815/942-2920 BBS Ltr. #76-775 November 4, 1976 Mr. James Keppler, Regional Director Directorate of Operations -.Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Enclosed please find Reportable Occurrence report number 50-249/1976-23. This report is being submitted to your office in accordance with the Dresden Nuclear Station Techriical Section 6.6.B. A n n . : . *1Y) _/) .. * -I-. .. . B. Stephensori * tation Superintendent. . Dresden Nuclear Power Station BBS :jo Enclosure cc: Director of Inspection & *Enforcement . Direct'or of Management Information & Program Control File/NRC  
{{#Wiki_filter:.* . Comrnonv.h Edison
. LICENSEE EVd\JT REPOR. *. -. . * .. ' CONTROL BLOCK: I ' I *.1 1. I I (PLEASE PRll'JT ALL REQUIRED INFORMATION) ' 1 6 .* '*. LICENSEE * < NAME .@El I I I L. ID IR I s 13 I 7 8 9 ' 14 CATEGORY REPORT TYPE. LICENSE NUMBER 10101-10101010101-10101 15 25 REPORT SOURCE OOCl\ET NUM6ER * LICENSE TYPE 1!1111111111 26 ' 30 EVENT TYPE 10131 '31 ' 32' EVENT* DATE REPORT DATE lof1 I coN1 I I I 7 8 57 58' llJ 59 LLl 60 61 68 11 IOIOl?l71(,l .*II II 1014171(, L 69 74 75 80 EVENT DESCRIPTION . (filg].lD!JRtAJ.G-REFUELING-OUTAGE LDC.AL l.t:Ak-:-RATE TESTING; *LPC/ PRtrnARV I 7* 8' 9 . ' 80. lol31 ltSO.L..ATION'. CA*IE:CI< VfU;V* 3-!S-O/-J.5& &#xa3;XHtBtT&#xa3;.D A l...EAr<AC-&#xa3; RAT&#xa3;. ... U!J' I, 7 Ei' 9 ' . ,. ' ' ' ' 80 IEXC&#xa3;$$'0F /HT:; T&#xa3;CH SP&#xa3;.C. /_JM/{ OF SC'l="H. TH* VAL.VE: I 7 8 9 ' ' ' ' ' ' 80 10'51 lusED VO f6R<YYI THE. 4'?'-Psf(:; DECAY 7EST BouJVDl1R..Y .. fYlANuALf 7 8 9 i ' ' ' ' ' ' ' " 80 lolsl I VAt..VE'.' 3-15&deg;0! -:Y,,B J 1-lfJD A $ IGNI FICA NT WATER HC/IJ) PR&#xa3;s&#xa3;NTj CONSEQLJOJT1..y,, I 7 8 9. * . . . PRIME * . (5,&#xa3;* /IT!FICHEV -<;;ft&#xa3;GT) 80 . * SYSTEM CAUSE COMPONENT COMPON!:NT -. . CODE CODE * COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION @0 ISIFLlsJ 1v1AIL1v1&#xa3;1x1 lt!J L'Ll 7 8 9 10 ' 11 12 17 ' 43 44 4 7 48 . CAUSE DES.CA!PTION l::TJ1&#xa3; VA/..-1/E f:fll L-UR.6 CAUSED Bi EXCESS I 116 ])15C-To -SEAi J 7 8 9 ' 80 lo'91 l1r1cs J.&#xa3;AK-fK-G: A77R.t8UIED, .. To TH&#xa3; PREsEl'JCG.* OE DtRTA*No * I 7 8 9 ' ', ' ' ' 80. ' (iE1 .I S:CRATc.HC:S OtJ THE $&#xa3;fl'0 APPARENTLY IHE REs()t,..T oF.Jv'ORWl,fiL .W&#xa3;AR. J ' ''7 ;*, 8 9,: FACILllY '' '' ' METHOD OF ' . co ' STATUS * % .. POWER OTHER STATUS -OISCOVEAY * DISCOVERY DESC.RIPTION EE] , lHJ * l O 16 l 61 *1..__"'""-'.AJ'--A _ ___,I . lBJ ,__,,..-.N-.;,..11'-'--. _ ___,! . 7. ** 0** 9* * .10 * * 12 13 44 ** 45 **. 46 so FORM OF ACTIVITY CONTENT *RELEASED OF RELEASE AMOUNT OF ACTIVITY rn . lZJ * *I.__* __ ______. I LOCATION OF RELEASE 7 8 9 10 11 44 45 ' 80 PERSONNEL EXPOSURES NUMBER * * TYPE DESCRIPTION lo Io JO I : . 7 * *a s 11 * 12.. 13 ea. '. PERS'ONNEL INJURIES NUMBER . OESCRIPTION v. [EJ*1n10.l.ol L--..;. .. _**-* _A_f1_. _* --------------------J 7 8 11 12 80 OFFSITE CONSEQUENCES .Elfil I A/A 7 8 9 80 . LOSS DAMAGE . TO FACILITY TYPE .DESCRIPTION * A)ff' 7 8 9 10 80 PUBLICITY l:illl 7 8 ADDITIONAL FACTOfiS (1JUJ /v*>0' 7 89 80 EEi 7 89 BC NAME: __ R;._A_/i_V_])_o_'-_* *_?_1: ...... 1 _c_.* _w_c._:-_r_D_M_'E----'R"-. PHONE: &#xa3;xT. d...G 5
* Dresde,1 Nuclear Power Station R.R. #i Morris, Illinois 60450 Telephone 815/942-2920 BBS Ltr. #76-775                                 November 4, 1976 Mr. James G~ Keppler, Regional Director Directorate of R~gulatory Operations -.Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Enclosed please find Reportable Occurrence report number 50-249/1976-23.
, . . ... .. ,. '* .. ;; . . ; ** EVENT DESCRIPTION (Continued) the as-found leakage of 61.0 SCFH was attributed entirely to leakage through check valve 1501-25B. A second leak test using valves 1501-26B, i501-22B, and 1001-SB as boundaries yielded a leakage rate of 4.2 SCFH: Since .the second test volume included the volume of the previous test, total through-leakage for the penetration was well under the Tech Spec limit. A similar valve on Unit-2 failed 16cal testing in early 1975. (50-249/1976-23) CAUSE DESCRIPTION. (Continued) The valve was disassembled, the seat was lapped, and the packing and _Flexitallic gasket were replaced. Leak-rate testing of the reassembled valve was satisfactory. In 1975, a test/drain line was installed on this penetration which permitted leak-rate testing of check valve 3-1501-25B for the first time since unit oper-ation began. Since this valve has performed* satisfactorily over a period of . several years, testing of this vaLve on an approximately annual basis should permit timely identification of a recurring problem. * Valve 3-15.0l-25B is a 16-inch tilting disc check valve, manufactured by.Atwood and Morrill Company, Inc.
This report is being submitted to your office in accordance with the Dresden Nuclear Powe~ Station Techriical ~pecifications, Section 6.6.B.
}}
A   n n.: .*1Y).. _/) ~. * -I- .
h un~              ~
                                                  . B. Stephensori
* tation Superintendent.       .
Dresden Nuclear Power Station BBS :jo Enclosure cc:   Director of Inspection & *Enforcement
    . Direct'or of Management Information & Program Control File/NRC
 
                              ~*                                                  .     LICENSEE EVd\JT REPOR.                                                   *.         -. .                 *..
                                  ' CONTROL BLOCK:                         I '           I *.1 1. I I                                             (PLEASE PRll'JT ALL REQUIRED INFORMATION)
                                                                        '   1                             6 LICENSEE                                                                                                                LICENSE                        EVENT
        * <                         NAME                                                       LICENSE NUMBER                                                TYPE                          TYPE
        .@El II I L. ID IR I s 13 I                                       10101-10101010101-10101                                              1!1111111111 10131 7       8 9                                         ' 14           15                                                      25         26                         ' 30 '31 ' 32' REPORT            REPORT CATEGORY                TYPE.          SOURCE                  OOCl\ET NUM6ER
* EVENT* DATE                                REPORT DATE lof1 IcoN1 I I I llJ LLl                                                     101s101~101~1~191                              11 IOIOl?l71(,l                             .*II   II 1014171(, L 7        8            57        58'              59            60          61                                    68      69                                    74     75                           80 EVENT DESCRIPTION .
(filg].lD!JRtAJ.G-                         REFUELING- OUTAGE                                   LDC.AL l.t:Ak-:-RATE TESTING; *LPC/                                                     PRtrnARV           I 7*       8' 9       .                                                   '                                                                                                                                 80.
7 lol31Ei' 9ltSO.L..ATION'.
CA*IE:CI<
VfU;V       3-!S-O/-J.5&
                                                                                                                                &#xa3;XHtBtT&#xa3;.D                 A         l...EAr<AC-&#xa3; RAT&#xa3;.... U!J'
                                                                                                                                                                                '      '                        80 I,
7
        ~ IEXC&#xa3;$$'0F /HT:; T&#xa3;CH SP&#xa3;.C. /_JM/{ OF .J.Cf.~f!/_. SC'l="H. TH OTH~g*. VAL.VE:
8 9'           ' ' ''       '                                                                                                                                                                   80 I
10'581      lusED             VO             f6R<YYI THE. 4'?'-Psf(:; PRESSUfV~                                          DECAY                 7EST BouJVDl1R..Y .. fYlANuALf 7           9                   i                                                                       '   '     ''         '                 '                             '       "               80 lolsl I VAt..VE'.' 3- 15&deg;0! -:Y,,B J                                         1-lfJD A $ IGNI FICA NT WATER HC/IJ) PR&#xa3;s&#xa3;NTj CONSEQLJOJT1..y,, I 7       8 9.           * ..                                     .                               PRIME               *       .                           (5,&#xa3; /IT!FICHEV -<;;ft&#xa3;GT)                   80
        .
* SYSTEM         CAUSE                                                           COMPONENT                 COMPON!:NT                                               -             .
                      . CODE         CODE
* COMPONENT CODE                   SUPPLIER               MANUFACTURER                     VIOLATION
        @0 ISIFLlsJ                                         1v1AIL1v1&#xa3;1x1                               lt!J             1A1s1*~1s1                                L'Ll 7       8 9       10           ' 11                 12                                 17     ' 43             44                         47                48
                  . CAUSE DES.CA!PTION
        ~ l::TJ1&#xa3; VA/..-1/E f:fll L-UR.6 'WA~ CAUSED Bi EXCESS I 116 ])15C-To -SEAi 1-&#xa3;AKAG-~.                                                                                                                    J 7       8 9                                                 '                                                                                                                                           80 lo'91 l1r1cs J.&#xa3;AK-fK-G: i,.JA~ A77R.t8UIED, ..To TH&#xa3; PREsEl'JCG.* OE DtRTA*No
* SIYIAL-t~                                                                                                                I 7       8 9                 '                                                                                                                         ', '                                       ' ' 80. '
,.~.: (iE1 .I S:CRATc.HC:S OtJ THE Vf/LV~ $&#xa3;fl'0 APPARENTLY IHE REs()t,..T oF.Jv'ORWl,fiL .W&#xa3;AR. J
  ' '' 7 ;*, 8 9 ,: FACILllY         ''       ''             '                                                 METHOD OF                                 '    'Js:t:E-:/rrjA~/t;F,.P ~}:/.!)            . co
                        ' STATUS                 * %.. POWER                             OTHER STATUS       -   OISCOVEAY
* DISCOVERY DESC.RIPTION EE] , 9*lHJ
* lO 16 l *6112                *1..__"'""-'.AJ'--A_      ___,I44 .** lBJ           ,__,,..-.N-.;,..11'-'--.---~..,.-.-'-._-_                                 ___,!
    . 7.
* 0**                         * .10
* 13                                       45     **. 46                                                                           so FORM OF ACTIVITY         CONTENT rn .lZJ 7        8
                      *RELEASED 9
OF RELEASE
* l~J 10          11 AMOUNT OF ACTIVITY
                                                              *I.__*--~N_ll_ _______.
44 I
45    '
LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER           *
* TYPE               DESCRIPTION
        ~            lo Io JO11I : *~                        . ~-.....::.JtJ_tt~--,---.,.---------~-------~-~-"-'-'-'-:-'-'------__.___,
7 * *a        s                            12.. 13                                                                                                                                                      ea.
            '.     PERS'ONNEL INJURIES NUMBER .                OESCRIPTION            v.
[EJ*1n10.l.ol                            L - -.
                                                        ; ._ * * -
* _A_f1_._*- - - - - - - - - - - - - - - - - - - - J 7        8  ~                11      12                                                                                                                                                                80 OFFSITE CONSEQUENCES
      .Elfil I                      A/A 7        8 9                                                                                                                                                                                            80
                  . LOSS ~F;l DAMAGE . TO FACILITY TYPE        .DESCRIPTION *
        ~ .~                                            A)ff' 7        8 9            10                                                                                                                                                                              80 PUBLICITY l:illl8 7            81..;_---L.~L-----------------,-------------'-----.,---~--'-----"------.---::-2~J ADDITIONAL FACTOfiS (1JUJ                                    /v*>0' 7      89                                                                                                                                                                                              80 EEi89 7                                                                                                                                                                                                      BC NAME: _ _            R;._A_/i_V_])_o_'-_**_?_1:...... 1 _c_.*_w_c._:-_r_D_M_'E----'R"-.---~ PHONE: &#xa3;xT.                                      d...G 5
 
EVENT DESCRIPTION (Continued) the as-found leakage of 61.0 SCFH was attributed entirely to leakage through check valve 1501-25B. A second leak test using valves 1501-26B, i501-22B, and 1001-SB as boundaries yielded a leakage rate of 4.2 SCFH: Since .the second test volume included the volume of the previous test, total through-leakage for the penetration was well under the Tech Spec limit. A similar valve on Unit-2 failed 16cal leak~rate testing in early 1975. (50-249/1976-23)
CAUSE DESCRIPTION. (Continued)
The valve was disassembled, the seat was lapped, and the packing and _Flexitallic gasket were replaced. Leak-rate testing of the reassembled valve was satisfactory.
In 1975, a test/drain line was installed on this penetration which permitted leak-rate testing of check valve 3-1501-25B for the first time since unit oper-ation began. Since this valve has performed* satisfactorily over a period of     .
several years, testing of this vaLve on an approximately annual basis should permit timely identification of a recurring problem.
* Valve 3-15.0l-25B is a 16-inch tilting disc check valve, manufactured by.Atwood and Morrill Company, Inc.
~  ..
;;  .}}

Latest revision as of 08:07, 24 February 2020

Letter Submitting Reportable Occurrence Number 050-249/1976-23 in Accordance with Technical Specifications, Section 6.6.B
ML17252A246
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 11/04/1976
From: Stephenson B
Commonwealth Edison Co
To: James Keppler
NRC/RGN-III
References
BBS Ltr. #76-775
Download: ML17252A246 (3)


Text

.* . Comrnonv.h Edison

  • Dresde,1 Nuclear Power Station R.R. #i Morris, Illinois 60450 Telephone 815/942-2920 BBS Ltr. #76-775 November 4, 1976 Mr. James G~ Keppler, Regional Director Directorate of R~gulatory Operations -.Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Enclosed please find Reportable Occurrence report number 50-249/1976-23.

This report is being submitted to your office in accordance with the Dresden Nuclear Powe~ Station Techriical ~pecifications, Section 6.6.B.

A n n.: .*1Y).. _/) ~. * -I- .

h un~ ~

. B. Stephensori

  • tation Superintendent. .

Dresden Nuclear Power Station BBS :jo Enclosure cc: Director of Inspection & *Enforcement

. Direct'or of Management Information & Program Control File/NRC

~* . LICENSEE EVd\JT REPOR. *. -. . *..

' CONTROL BLOCK: I ' I *.1 1. I I (PLEASE PRll'JT ALL REQUIRED INFORMATION)

' 1 6 LICENSEE LICENSE EVENT

  • < NAME LICENSE NUMBER TYPE TYPE

.@El II I L. ID IR I s 13 I 10101-10101010101-10101 1!1111111111 10131 7 8 9 ' 14 15 25 26 ' 30 '31 ' 32' REPORT REPORT CATEGORY TYPE. SOURCE OOCl\ET NUM6ER

  • EVENT* DATE REPORT DATE lof1 IcoN1 I I I llJ LLl 101s101~101~1~191 11 IOIOl?l71(,l .*II II 1014171(, L 7 8 57 58' 59 60 61 68 69 74 75 80 EVENT DESCRIPTION .

(filg].lD!JRtAJ.G- REFUELING- OUTAGE LDC.AL l.t:Ak-:-RATE TESTING; *LPC/ PRtrnARV I 7* 8' 9 . ' 80.

7 lol31Ei' 9ltSO.L..ATION'.

CA*IE:CI<

VfU;V 3-!S-O/-J.5&

£XHtBtT£.D A l...EAr<AC-£ RAT£.... U!J'

' ' 80 I,

7

~ IEXC£$$'0F /HT:; T£CH SP£.C. /_JM/{ OF .J.Cf.~f!/_. SC'l="H. TH OTH~g*. VAL.VE:

8 9' ' ' ' 80 I

10'581 lusED VO f6R<YYI THE. 4'?'-Psf(:; PRESSUfV~ DECAY 7EST BouJVDl1R..Y .. fYlANuALf 7 9 i ' ' ' ' ' " 80 lolsl I VAt..VE'.' 3- 15°0! -:Y,,B J 1-lfJD A $ IGNI FICA NT WATER HC/IJ) PR£s£NTj CONSEQLJOJT1..y,, I 7 8 9. * .. . PRIME * . (5,£ /IT!FICHEV -<;;ft£GT) 80

.

  • SYSTEM CAUSE COMPONENT COMPON!:NT - .

. CODE CODE

  • COMPONENT CODE SUPPLIER MANUFACTURER VIOLATION

@0 ISIFLlsJ 1v1AIL1v1£1x1 lt!J 1A1s1*~1s1 L'Ll 7 8 9 10 ' 11 12 17 ' 43 44 47 48

. CAUSE DES.CA!PTION

~ l::TJ1£ VA/..-1/E f:fll L-UR.6 'WA~ CAUSED Bi EXCESS I 116 ])15C-To -SEAi 1-£AKAG-~. J 7 8 9 ' 80 lo'91 l1r1cs J.£AK-fK-G: i,.JA~ A77R.t8UIED, ..To TH£ PREsEl'JCG.* OE DtRTA*No

  • SIYIAL-t~ I 7 8 9 ' ', ' ' ' 80. '

,.~.: (iE1 .I S:CRATc.HC:S OtJ THE Vf/LV~ $£fl'0 APPARENTLY IHE REs()t,..T oF.Jv'ORWl,fiL .W£AR. J

' 7 ;*, 8 9 ,: FACILllY ' METHOD OF ' 'Js:t:E-:/rrjA~/t;F,.P ~}:/.!) . co

' STATUS * %.. POWER OTHER STATUS - OISCOVEAY

  • DISCOVERY DESC.RIPTION EE] , 9*lHJ
  • lO 16 l *6112 *1..__"'""-'.AJ'--A_ ___,I44 .** lBJ ,__,,..-.N-.;,..11'-'--.---~..,.-.-'-._-_ ___,!

. 7.

  • 0** * .10
  • 13 45 **. 46 so FORM OF ACTIVITY CONTENT rn .lZJ 7 8
  • RELEASED 9

OF RELEASE

  • l~J 10 11 AMOUNT OF ACTIVITY
  • I.__*--~N_ll_ _______.

44 I

45 '

LOCATION OF RELEASE 80 PERSONNEL EXPOSURES NUMBER *

  • TYPE DESCRIPTION

~ lo Io JO11I : *~ . ~-.....::.JtJ_tt~--,---.,.---------~-------~-~-"-'-'-'-:-'-'------__.___,

7 * *a s 12.. 13 ea.

'. PERS'ONNEL INJURIES NUMBER . OESCRIPTION v.

[EJ*1n10.l.ol L - -.

._ * * -
  • _A_f1_._*- - - - - - - - - - - - - - - - - - - - J 7 8 ~ 11 12 80 OFFSITE CONSEQUENCES

.Elfil I A/A 7 8 9 80

. LOSS ~F;l DAMAGE . TO FACILITY TYPE .DESCRIPTION *

~ .~ A)ff' 7 8 9 10 80 PUBLICITY l:illl8 7 81..;_---L.~L-----------------,-------------'-----.,---~--'-----"------.---::-2~J ADDITIONAL FACTOfiS (1JUJ /v*>0' 7 89 80 EEi89 7 BC NAME: _ _ R;._A_/i_V_])_o_'-_**_?_1:...... 1 _c_.*_w_c._:-_r_D_M_'E----'R"-.---~ PHONE: £xT. d...G 5

EVENT DESCRIPTION (Continued) the as-found leakage of 61.0 SCFH was attributed entirely to leakage through check valve 1501-25B. A second leak test using valves 1501-26B, i501-22B, and 1001-SB as boundaries yielded a leakage rate of 4.2 SCFH: Since .the second test volume included the volume of the previous test, total through-leakage for the penetration was well under the Tech Spec limit. A similar valve on Unit-2 failed 16cal leak~rate testing in early 1975. (50-249/1976-23)

CAUSE DESCRIPTION. (Continued)

The valve was disassembled, the seat was lapped, and the packing and _Flexitallic gasket were replaced. Leak-rate testing of the reassembled valve was satisfactory.

In 1975, a test/drain line was installed on this penetration which permitted leak-rate testing of check valve 3-1501-25B for the first time since unit oper-ation began. Since this valve has performed* satisfactorily over a period of .

several years, testing of this vaLve on an approximately annual basis should permit timely identification of a recurring problem.

  • Valve 3-15.0l-25B is a 16-inch tilting disc check valve, manufactured by.Atwood and Morrill Company, Inc.

~ ..

.