{{#Wiki_filter:WATERFORD - UNIT 33/4 6-13AMENDMENT NO. 199
{{#Wiki_filter:CONTAINMENT SYSTEMS AIR TEMPERATURE LIMITING CONDITION FOR OPERATION 3.6.1.5 Primary containment average air temperature shall be > 95&deg;F* and < 120 &deg;F.
, CONTAINMENT SYSTEMS AIR TEMPERATURE LIMITING CONDITION FOR OPERATION 3.6.1.5 Primary containment average air temperature shall be >
APPLICABILITY: MODES 1, 2, 3, and 4.
95&deg;F* and < 120 &deg;F.APPLICABILITY:
ACTION:
MODES 1, 2, 3, and 4.
: a. If the minimum containment average air temperature is less than 95&deg;F* but greater than or equal to 90&deg;F*, then within 8 hours either restore containment air temperature to greater than or equal to 95&deg;F or reduce the peak linear heat generation rate limit in accordance with the COLR. Otherwise, be in at least HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.
ACTION:a.If the minimum containment average air temperature is less than 95&deg;F* but greater than or equal to 90&deg;F*, then within 8 hours either restore containment air temperature to greater
: b. If the minimum containment average air temperature is less than 90&deg;F, then restore containment air temperature to greater than or equal to 95&deg;F within 8 hours or be in at least HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.
 
: c. If maximum containment average air temperature is greater than 120&deg;F, then restore containment air temperature to less than or equal to 120&deg;F within 8 hours or be in at least HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the following 30 hours.
than or equal to 95&deg;F or reduce the peak linear heat generation rate limit in accordance
SURVEILLANCE REQUIREMENTS 4.6.1.5 The primary containment average air temperature shall be the arithmetical average of the temperatures at any three of the following locations and shall be determined at least once per 24 hours:
 
Location
with the COLR. Otherwise, be in at least HOT STANDBY within the next 6 hours and in
: a. Containment Fan Cooler No. 1A Air Intake
 
COLD SHUTDOWN within the following 30 hours.b.If the minimum containment average air temperature is less than 90&deg;F, then restore containment air temperature to greater than or equal to 95&deg;F within 8 hours or be in at
 
least HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the
 
following 30 hours.c.If maximum containment average air temperature is greater than 120&deg;F, then restore containment air temperature to less than or equal to 120&deg;F within 8 hours or be in at least
 
HOT STANDBY within the next 6 hours and in COLD SHUTDOWN within the following 30
 
hours.SURVEILLANCE REQUIREMENTS 4.6.1.5 The primary containment average air temperature shall be the arithmetical average of the temperatures at any three of the following locations
 
and shall be determined at least once per 24 hours:
Location a. Containment Fan Cooler No. 1A Air Intake
: b. Containment Fan Cooler No. 1B Air Intake
: b. Containment Fan Cooler No. 1B Air Intake
: c. Containment Fan Cooler No. 1C Air Intake
: c. Containment Fan Cooler No. 1C Air Intake
Line 46: Line 33:
____________
____________
* The minimum containment average air temperature limit is only applicable at greater than 70%
* The minimum containment average air temperature limit is only applicable at greater than 70%
RATED THERMAL POWER.
RATED THERMAL POWER.
214CorrectedbyletterdatedMay9,2008}}
WATERFORD - UNIT 3                          3/4 6-13                    AMENDMENT NO. 199 , 214 Corrected by letter dated May 9, 2008}}

Revision as of 17:09, 14 November 2019

Tech Spec Page for Correction to Amendment 214 Request to Support Next Generation Fuel; Review & Approval of Revised ECCS Performance Analysis; & Review & Approval of Supplement to ECCS Performance Analysis
ML081270036
Person / Time
Site: Waterford Entergy icon.png
Issue date: 05/09/2008
From:
NRC/NRR/ADRO/DORL/LPLIV
To:
Kalyanam N, NRR/DORL/LPL4, 415-1480
Shared Package
ML081260523 List:
References
TAC MD6299, TAC MD6363, TAC MD6954
Download: ML081270036 (1)


Text

CONTAINMENT SYSTEMS AIR TEMPERATURE LIMITING CONDITION FOR OPERATION 3.6.1.5 Primary containment average air temperature shall be > 95°F* and < 120 °F.

APPLICABILITY: MODES 1, 2, 3, and 4.

ACTION:

a. If the minimum containment average air temperature is less than 95°F* but greater than or equal to 90°F*, then within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> either restore containment air temperature to greater than or equal to 95°F or reduce the peak linear heat generation rate limit in accordance with the COLR. Otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
b. If the minimum containment average air temperature is less than 90°F, then restore containment air temperature to greater than or equal to 95°F within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
c. If maximum containment average air temperature is greater than 120°F, then restore containment air temperature to less than or equal to 120°F within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.1.5 The primary containment average air temperature shall be the arithmetical average of the temperatures at any three of the following locations and shall be determined at least once per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s:

Location

a. Containment Fan Cooler No. 1A Air Intake
b. Containment Fan Cooler No. 1B Air Intake
c. Containment Fan Cooler No. 1C Air Intake
d. Containment Fan Cooler No. 1D Air Intake

____________

  • The minimum containment average air temperature limit is only applicable at greater than 70%

RATED THERMAL POWER.

WATERFORD - UNIT 3 3/4 6-13 AMENDMENT NO. 199 , 214 Corrected by letter dated May 9, 2008