ENS 43438: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| facility = Areva Np Inc Richland
| facility = Areva Np Inc Richland
| Organization =  
| Organization =  
| license number = Snm-1227
| license number = SNM-1227
| region = 2
| region = 2
| state = Washington
| state = Washington
Line 16: Line 16:
| event date = 06/21/2007 01:42 PDT
| event date = 06/21/2007 01:42 PDT
| last update date = 06/21/2007
| last update date = 06/21/2007
| title = Fire Due To Sequencing Problem
| title = Fire Due to Sequencing Problem
| event text = At approximately 0142 hours on 6/21/2007, during Solid Waste Uranium Recovery (SWUR) operations, a sequencing problem caused a cardboard box containing combustible waste with about [Deleted] U-235 to be fed on top of a closed feed hopper door. As the equipment cycled the incinerator fire door, the box, which was on top of the feed hopper door ignited. The box was inside the feed hopper containment shroud when it ignited. The integrity of the containment shroud remained intact during the fire. However, some smoke did escape into the room.  
| event text = At approximately 0142 hours on 6/21/2007, during Solid Waste Uranium Recovery (SWUR) operations, a sequencing problem caused a cardboard box containing combustible waste with about [Deleted] U-235 to be fed on top of a closed feed hopper door. As the equipment cycled the incinerator fire door, the box, which was on top of the feed hopper door ignited. The box was inside the feed hopper containment shroud when it ignited. The integrity of the containment shroud remained intact during the fire. However, some smoke did escape into the room.  
Operational personnel put out the fire (a single box of 3.5 cubic feet) using a hand held fire extinguisher.  
Operational personnel put out the fire (a single box of 3.5 cubic feet) using a hand held fire extinguisher.  

Latest revision as of 18:32, 24 November 2018

ENS 43438 +/-
Where
Areva Np Inc Richland
Richland, Washington (NRC Region 2)
License number: SNM-1227
Reporting
10 CFR 70.50(b)(4), SNM fire or explosion
Time - Person (Reporting Time:+7.73 h0.322 days <br />0.046 weeks <br />0.0106 months <br />)
Opened: Robert Link
16:26 Jun 21, 2007
NRC Officer: Jason Kozal
Last Updated: Jun 21, 2007
43438 - NRC Website