{{#Wiki_filter:TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A
==SUMMARY==
DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to
the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island
Nuclear Station Unit 1.
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS
Section 
==1.0 GENERAL==
===1.1 OPERATING===
ENVIRONMENT
===2.0 SEISMIC===
DESIGN DESCRIPTION
===2.1 GENERAL===
APPROACH
====2.1.1 CRITERIA====
===2.2 METHOD===
====2.2.1 GENERAL====
====2.2.2 PROCEDURE====
====2.2.3 UTILIZATION====
====2.2.4 DETAILED====
ANALYSIS
===2.3 RESULTS===
2.4
==SUMMARY==
===3.0 DESIGN===
SUMMARIES - MAJOR COMPONENTS
===3.1 HOUSINGS===
===3.2 RELIEF===
VALVES
3.3 MIST ELIMINATORS
===3.4 COILS===
3.5 FAN MOTOR UNITS 3.5.1 FANS
====3.5.2 MOTORS====
==4.0 REFERENCES==
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES
Figure Title 6A-1 Reactor Building Fan Assembly-External View
6A-2 Met Ed - Total House
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program
6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
6A-5 Fan High Pressure Test Duct
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A
==SUMMARY==
DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to
the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island
Nuclear Station Unit 1.
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS
Section 
==1.0 GENERAL==
===1.1 OPERATING===
ENVIRONMENT
===2.0 SEISMIC===
DESIGN DESCRIPTION
===2.1 GENERAL===
APPROACH
====2.1.1 CRITERIA====
===2.2 METHOD===
====2.2.1 GENERAL====
====2.2.2 PROCEDURE====
====2.2.3 UTILIZATION====
====2.2.4 DETAILED====
ANALYSIS
===2.3 RESULTS===
2.4
==SUMMARY==
===3.0 DESIGN===
SUMMARIES - MAJOR COMPONENTS
===3.1 HOUSINGS===
===3.2 RELIEF===
VALVES
3.3 MIST ELIMINATORS
===3.4 COILS===
3.5 FAN MOTOR UNITS 3.5.1 FANS
====3.5.2 MOTORS====
==4.0 REFERENCES==
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES
Figure Title 6A-1 Reactor Building Fan Assembly-External View
6A-2 Met Ed - Total House
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program
6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
6A-5 Fan High Pressure Test Duct}}

Latest revision as of 13:50, 9 October 2018

022_06 Appendix 06A Reactor Building Fan Cooler Assembly
ML16127A500
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 04/11/2016
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16127A520 List: ... further results
References
TMI-16-035
Download: ML16127A500 (22)


Text

TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A

SUMMARY

DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY

The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to

the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island

Nuclear Station Unit 1.

(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)

TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS

Section

1.0 GENERAL

1.1 OPERATING

ENVIRONMENT

2.0 SEISMIC

DESIGN DESCRIPTION

2.1 GENERAL

APPROACH

2.1.1 CRITERIA

2.2 METHOD

2.2.1 GENERAL

2.2.2 PROCEDURE

2.2.3 UTILIZATION

2.2.4 DETAILED

ANALYSIS

2.3 RESULTS

2.4

SUMMARY

3.0 DESIGN

SUMMARIES - MAJOR COMPONENTS

3.1 HOUSINGS

3.2 RELIEF

VALVES

3.3 MIST ELIMINATORS

3.4 COILS

3.5 FAN MOTOR UNITS 3.5.1 FANS

3.5.2 MOTORS

4.0 REFERENCES

TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES

Figure Title 6A-1 Reactor Building Fan Assembly-External View

6A-2 Met Ed - Total House

6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program

6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section

6A-5 Fan High Pressure Test Duct

TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A

SUMMARY

DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY

The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to

the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island

Nuclear Station Unit 1.

(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)

TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS

Section

1.0 GENERAL

1.1 OPERATING

ENVIRONMENT

2.0 SEISMIC

DESIGN DESCRIPTION

2.1 GENERAL

APPROACH

2.1.1 CRITERIA

2.2 METHOD

2.2.1 GENERAL

2.2.2 PROCEDURE

2.2.3 UTILIZATION

2.2.4 DETAILED

ANALYSIS

2.3 RESULTS

2.4

SUMMARY

3.0 DESIGN

SUMMARIES - MAJOR COMPONENTS

3.1 HOUSINGS

3.2 RELIEF

VALVES

3.3 MIST ELIMINATORS

3.4 COILS

3.5 FAN MOTOR UNITS 3.5.1 FANS

3.5.2 MOTORS

4.0 REFERENCES

TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES

Figure Title 6A-1 Reactor Building Fan Assembly-External View

6A-2 Met Ed - Total House

6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program

6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section

6A-5 Fan High Pressure Test Duct