{{#Wiki_filter:TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A | |||
==SUMMARY== | |||
DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY | |||
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to | |||
the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island | |||
Nuclear Station Unit 1. | |||
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971) | |||
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS | |||
Section | |||
==1.0 GENERAL== | |||
===1.1 OPERATING=== | |||
ENVIRONMENT | |||
===2.0 SEISMIC=== | |||
DESIGN DESCRIPTION | |||
===2.1 GENERAL=== | |||
APPROACH | |||
====2.1.1 CRITERIA==== | |||
===2.2 METHOD=== | |||
====2.2.1 GENERAL==== | |||
====2.2.2 PROCEDURE==== | |||
====2.2.3 UTILIZATION==== | |||
====2.2.4 DETAILED==== | |||
ANALYSIS | |||
===2.3 RESULTS=== | |||
2.4 | |||
==SUMMARY== | |||
===3.0 DESIGN=== | |||
SUMMARIES - MAJOR COMPONENTS | |||
===3.1 HOUSINGS=== | |||
===3.2 RELIEF=== | |||
VALVES | |||
3.3 MIST ELIMINATORS | |||
===3.4 COILS=== | |||
3.5 FAN MOTOR UNITS 3.5.1 FANS | |||
====3.5.2 MOTORS==== | |||
==4.0 REFERENCES== | |||
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES | |||
Figure Title 6A-1 Reactor Building Fan Assembly-External View | |||
6A-2 Met Ed - Total House | |||
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program | |||
6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section | |||
6A-5 Fan High Pressure Test Duct | |||
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A | |||
==SUMMARY== | |||
DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY | |||
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to | |||
the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island | |||
Nuclear Station Unit 1. | |||
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971) | |||
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS | |||
Section | |||
==1.0 GENERAL== | |||
===1.1 OPERATING=== | |||
ENVIRONMENT | |||
===2.0 SEISMIC=== | |||
DESIGN DESCRIPTION | |||
===2.1 GENERAL=== | |||
APPROACH | |||
====2.1.1 CRITERIA==== | |||
===2.2 METHOD=== | |||
====2.2.1 GENERAL==== | |||
====2.2.2 PROCEDURE==== | |||
====2.2.3 UTILIZATION==== | |||
====2.2.4 DETAILED==== | |||
ANALYSIS | |||
===2.3 RESULTS=== | |||
2.4 | |||
==SUMMARY== | |||
===3.0 DESIGN=== | |||
SUMMARIES - MAJOR COMPONENTS | |||
===3.1 HOUSINGS=== | |||
===3.2 RELIEF=== | |||
VALVES | |||
3.3 MIST ELIMINATORS | |||
===3.4 COILS=== | |||
3.5 FAN MOTOR UNITS 3.5.1 FANS | |||
====3.5.2 MOTORS==== | |||
==4.0 REFERENCES== | |||
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES | |||
Figure Title 6A-1 Reactor Building Fan Assembly-External View | |||
6A-2 Met Ed - Total House | |||
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program | |||
6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section | |||
6A-5 Fan High Pressure Test Duct}} |
Latest revision as of 13:50, 9 October 2018
ML16127A500 | |
Person / Time | |
---|---|
Site: | Three Mile Island |
Issue date: | 04/11/2016 |
From: | Exelon Generation Co |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML16127A520 | List:
|
References | |
TMI-16-035 | |
Download: ML16127A500 (22) | |
Text
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A
SUMMARY
DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to
the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island
Nuclear Station Unit 1.
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS
Section
1.0 GENERAL
1.1 OPERATING
ENVIRONMENT
2.0 SEISMIC
DESIGN DESCRIPTION
2.1 GENERAL
APPROACH
2.1.1 CRITERIA
2.2 METHOD
2.2.1 GENERAL
2.2.2 PROCEDURE
2.2.3 UTILIZATION
2.2.4 DETAILED
ANALYSIS
2.3 RESULTS
2.4
SUMMARY
3.0 DESIGN
SUMMARIES - MAJOR COMPONENTS
3.1 HOUSINGS
3.2 RELIEF
VALVES
3.3 MIST ELIMINATORS
3.4 COILS
3.5 FAN MOTOR UNITS 3.5.1 FANS
3.5.2 MOTORS
4.0 REFERENCES
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES
Figure Title 6A-1 Reactor Building Fan Assembly-External View
6A-2 Met Ed - Total House
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program
6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
6A-5 Fan High Pressure Test Duct
TMI-1 UFSAR APPENDIX 6A 6A-i REV. 18, APRIL 2006 APPENDIX 6A
SUMMARY
DESCRIPTION THREE MILE ISLAND NUCLEAR STATION UNIT 1 REACTOR BUILDING FAN COOLER ASSEMBLY
The material contained in Appendix 6A is a synopsis of American Air Filter's Topical Report to
the Metropolitan Edison Co. covering Reactor Building Fan Assemblies for Three Mile Island
Nuclear Station Unit 1.
(Originally issued with Amendment 17 to the FSAR, Dated 25, 1971)
TMI-1 UFSAR APPENDIX 6A 6A-ii REV. 18, APRIL 2006 TABLE OF CONTENTS
Section
1.0 GENERAL
1.1 OPERATING
ENVIRONMENT
2.0 SEISMIC
DESIGN DESCRIPTION
2.1 GENERAL
APPROACH
2.1.1 CRITERIA
2.2 METHOD
2.2.1 GENERAL
2.2.2 PROCEDURE
2.2.3 UTILIZATION
2.2.4 DETAILED
ANALYSIS
2.3 RESULTS
2.4
SUMMARY
3.0 DESIGN
SUMMARIES - MAJOR COMPONENTS
3.1 HOUSINGS
3.2 RELIEF
VALVES
3.3 MIST ELIMINATORS
3.4 COILS
3.5 FAN MOTOR UNITS 3.5.1 FANS
3.5.2 MOTORS
4.0 REFERENCES
TMI-1 UFSAR APPENDIX 6A 6A-iii REV. 18, APRIL 2006 LIST OF FIGURES
Figure Title 6A-1 Reactor Building Fan Assembly-External View
6A-2 Met Ed - Total House
6A-3 Met-Ed - End Section (Right End Shown) Adjusted to "Reduce" Number of Membersfor Computer Program
6A-4 Met-Ed - Center Section -Adjusted to Correspond with End Section
6A-5 Fan High Pressure Test Duct