Pages that link to "NRC Form age"
Jump to navigation
Jump to search
The following pages link to NRC Form age:
Displayed 19 items.
- LIC-93-0123, Requests to Credit Licensee on Next Invoice XT0280-93 & Insure That Future Charges for Review of Cents Code Billed to ABB-CE (← links)
- 05000339/LER-1989-008-01, :on 890806,ESF Valve 2-RS-MOV-201B Closed Inadvertently During Initial Performance of 2-PT-36.5.3A. Caused by Misidentification of Interlock for 2-RS-MOV-201B. Tech Spec 3.0.3 Entered & Deviation Rept Done (← links)
- 05000346/LER-1989-011, :on 890713,determined That Testing for Valves for Both Decay Heat Coolers Did Not Fully Satisfy Requirements of ASME Section Xi.Caused by Personnel Error. Procedure EN-DP-01200 Revised (← links)
- 05000321/LER-1989-007-02, :on 890517,recorders Declared Inoperable Since Recorders Found Not to Be Capable of Recording Full Range of Zero to 1E06 R/H as Required by Tech Specs.Caused by Wiring Error by Vendor.Monitors Rewired (← links)
- 05000312/LER-1986-031, :on 860804,hourly Instead of Continuous Fire Watch Performed.Caused by Operator Error.Fire Protection Coordinator Will Establish Agreed Upon Terminology for Fire Staff to Use When Communicating (← links)
- 05000311/LER-1987-002-01, :on 870118,wile Performing Troubleshooting on Nuclear Instrument Sys intermediate-range Channel N36, Reactor Trip Occurred.Caused by Personnel Error.Signs Placed to Caution Personnel Re Pulling Fuses (← links)
- 05000409/LER-1987-003, :on 870311,containment Bldg Gas Monitor Alarmed Causing Containment Bldg Ventilation Dampers & Vent Header Valve to Close.Caused by Dirty Contacts on Monitor Ratemeter Range Switch.Isolation Signal Reset (← links)
- 05000327/LER-1986-012, :on 860415,failure to Properly Stroke Time Containment Isolation Valve Noted.Caused by Incorrect Surveillance Requirement Procedure.Procedure Revised & Valves Stroke Timed to Closed Position (← links)
- 05000409/LER-1986-021, :on 860716,reactor Scram Occurred.Caused by Static Inverter 1A Transferring Alternate Source & Momentarily Deengergizing Scram Trains.Inverter Will Be Replaced Prior to Plant Startup (← links)
- 05000259/LER-1985-039, :on 850815,local Leak Rate Test Results Exceeded Tech Specs for Msivs,Primary Containment Penetrations & Isolation Valves.Cause Not Stated.Repair & Testing Underway (← links)
- 05000369/LER-1985-033-01, :on 851030,momentary Blackout on Train B Occurred.Caused by Nuclear Control Operator Inadvertently Opening Diesel Generator Breaker.Procedures for Blackout Implemented.Collars Installed on Generator (← links)
- 05000259/LER-1985-015-01, :on 850501,while Attempting to Adjust Reactor Cooling Flow by Throttling RHR Loop II Pump Discharge Valve Operation Observed No Indication of Valve Movement.Caused by Shorn Gear Assembly Spline Teeth (← links)
- 05000388/LER-1985-019-01, :on 850524,Limiting Condition for Operation 3.0.3, Motherhood Clause, Declared & Standby Gas Treatment Sys Suction Ductwork Access Doors Opened.Entry Required to Perform Fire Damper Surveillance (← links)
- 05000251/LER-1985-010-01, :on 850515,turbine & Reactor Trip Occurred. Caused by Actuation of ESF Relay Inadvertently Bumped by Const Worker While Performing App R Mods.Const Halted. Post-trip Review Found No Abnormal Conditions (← links)
- 05000259/LER-1985-007-02, :on 850318,handswitch Used for Purging Plant Stack Radiation Monitor Left in on Position,Allowing 2 H Unmonitored Release.Caused by Personnel Error.Switch Turned Off.Individual Reprimanded (← links)
- 05000285/LER-1984-024, :on 841126,unplanned Ventilation Isolation Actuation Sys Actuation Occurred.Caused by Operator Changing Ventilation Discharge Duck Monitor RM-061 to High Alert/Alarm Setpoints During Temp Inversion (← links)
- 05000318/LER-1984-007-01, :on 840824,PORV Override Handswitches Found in Override Position Rendering PORVs Inoperable.Caused by Procedural Inadequacy.Tech Specs Will Be Revised Re Operating Procedures (← links)
- 05000370/LER-1984-013-01, :on 840511,reactor Trip Occurred When Steam Generator 2D Level Dropped Below lo-lo Level Reactor Trip Setpoint.Caused by Failure of Check Valve 2CF-158 to Close. Valve Will Be Repaired During Next Outage (← links)
- 05000364/LER-1989-015, :on 891118,reactor Tripped Due to Turbine Trip. Caused by Voltage Transient in Power Circuit to Digital electro-hydraulic Control Sys & Inverter Failure.Inverter Repaired & Returned to Svc (← links)