Pages that link to "NRC Form 3b6A"
Jump to navigation
Jump to search
The following pages link to NRC Form 3b6A:
Displayed 16 items.
- ML20211G610 (← links)
- 05000331/LER-1998-003, :on 980410,invalid Esfas of Group III PCIS Was Noted.Caused by Procedure Deficiencies & Loss of Instrument AC Control Power.Revised Procedures & Reviewed Electrical Panel Labels & Associated Operating Procedures (← links)
- 05000423/LER-1998-034, :on 980614,manual Reactor Trip Initiated in Response to Malfunction of Control Rod Group Demand Position Indication Counters.Caused by Human Error.Control Rod Group Step Counters Modified to Correct Condition (← links)
- 05000317/LER-1999-005, :on 990720,corrosion Behavior & Onset of Oxide Spalling of High Duty Fuel Noted on Fuel Assemblies.Caused by Normal Phenomenon.Operability Evaluation for Current Cycle Operation Will Be Performed.With (← links)
- 05000269/LER-1998-017-01, :on 981128,missed Surveillance Was Noted.Caused by Inadequate Work Planning.Operations Mgt Expectations for Performance of Qpt SR Were Communicated to Appropriate Operations Personnel (← links)
- 05000336/LER-1990-016-02, :on 901009,inadvertent ESAS Actuation Occurred in Violation of Tech Specs (← links)
- 05000414/LER-1998-004-04, :on 980906,de-energization of Vital Bus & Actuation of LTOP Occurred.Caused by Error During Tagout. Power Was Restored to 2ETB IAW Plant Procedure AP/2/A/5500/ 07 & Individuals Involved Were Counseled Re Subject Error (← links)
- 05000213/LER-1996-012, :on 960611,determined That Feedwater Regulating Valve May Not Close During Slb.Caused by Assumption That Valve Would Isolate Against High Dp.Operator Assigned to Mcb to Verify That Feedwater MOVs Close After RT (← links)
- 05000282/LER-1997-003-02, :on 970325,discovered That Afp Will Trip on Low SG Pressure During Complete Loss of Feedwater ATWS Event. Operability Evaluation of Plant Was Performed (← links)
- 05000414/LER-1994-002, :on 940615,reactor Trip Breakers Opened Due to Component Failure.Failed Firing Cards Were Replaced, Remaining Firing Cards in Stock Tested & Procedures Revised (← links)
- 05000269/LER-1996-003, :on 960214,RC Makeup Sys Technically Inoperable for App R Scenario Due to Design Analysis,Sys Functional Design Deficiency.Compensatory Actions Taken to Limit Leakage & DBD Will Be Revised (← links)
- 05000328/LER-1994-015, :on 941208,failure to Perform Hourly Fire Watch as Required by TS Occurred.Caused by Inadequate Mgt Attention for Spent Fuel Pit Rerack Project.Fire Watch Personnel Briefed on Locked Doors (← links)
- 05000498/LER-1994-013, :on 940804,identified Two Cases of NUMARC 87-00 Criterion Not Being Satisfied.Caused by Failure to Confirm Validity of Blackout Program.Severe Weather Guidelines Revised (← links)
- 05000423/LER-1994-010-01, :on 940726,trains of Charging Declared Inoperable.Caused by Overly Restrictive Acceptance Criterion for Cooling Pump Bearing Oil Level.Cooling Pump Level Changed to Provide Appropriate Operability (← links)
- 05000499/LER-1994-006-01, :on 940711,discovered That Sp Used to Verify Operability of Accident Monitoring Instrumentation & Remote Shutdown Monitoring Instrumentation Inadequate.Sp Revised.W/ (← links)
- 05000423/LER-1993-022-02, :on 931219,manual Containment Isolation Valve Discovered Unlocked Due to Equipment Interface.Short Shank Padlocks Replaced W/Long Shank Padlocks (← links)