Pages that link to "05000395/LER-1982-016, Forwards Revised LER 82-016/03L-1.Detailed Event Analysis Encl"
Jump to navigation
Jump to search
The following pages link to 05000395/LER-1982-016, Forwards Revised LER 82-016/03L-1.Detailed Event Analysis Encl:
Displayed 24 items.
- 05000395/LER-1982-016 (redirect page) (← links)
- ML20064F453 (redirect page) (← links)
- 05000395/LER-1982-061, Forwards LER 82-061/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-044, Forwards LER 82-044/01T-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-045, Forwards LER 82-045/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-046, Forwards LER 82-046/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-048, Forwards LER 82-048/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-049, Forwards LER 82-049/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-043, Forwards LER 82-043/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-042, Forwards LER 82-042/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-039, Forwards LER 82-039/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-040, Forwards LER 82-040/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-038, Forwards LER 82-038/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-037, Forwards LER 82-037/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-036, Forwards LER 82-036/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-020, Forwards LER 82-020/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-017, Forwards LER 82-017/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-011, Forwards LER 82-011/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-064, Forwards LER 82-064/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-063, Forwards LER 82-063/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-062, Forwards LER 82-062/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-035-03, /03L-0:on 821103,plant Entered Mode 3 W/Boric Acid Tank B Level Instrument LI-163A Inoperable.Caused by Instrument Out of Calibr Due to Zero Shift on Transmitter. Instrument Recalibr (← links)
- 05000395/LER-1982-037-03, /03L-0:on 821104,steam Generator Blowdown Radiation Monitor (RM-L3) & Steam Generator Blowdown Discharge Radiation Monitor (RM-L10) Taken Out of Svc.Caused by Insufficient Sample Flow.Sys Aligned for RM-L10 (← links)
- 05000395/LER-1982-016, Forwards LER 82-016/03L-0.Detailed Event Analysis Encl (redirect page) (← links)
- ML20027D940 (redirect page) (← links)
- ML20027D941 (← links)
- 05000395/LER-1982-007, Forwards LER 82-007/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-006, Forwards LER 82-006/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-004, Forwards LER 82-004/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-005, Forwards LER 82-005/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-002, Forwards LER 82-002/03L-0 (← links)
- 05000395/LER-1982-055, Forwards LER 82-055/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-054, Forwards LER 82-054/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-052, Forwards LER 82-052/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-051, Forwards LER 82-051/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-001, Forwards LER 82-001/03L-0 (← links)
- 05000395/LER-1982-047, Forwards LER 82-047/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-041, Forwards LER 82-041/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-035, Forwards LER 82-035/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-034, Forwards LER 82-034/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-027, Forwards LER 82-027/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-028, Forwards LER 82-028/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-026, Forwards LER 82-026/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-025, Forwards LER 82-025/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-014, Forwards LER 82-014/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-010, Forwards LER 82-010/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-066, Forwards LER 82-066/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-003, Forwards LER 82-003/03L-0 (← links)
- 05000395/LER-1982-064-03, /03L-0:on 821223,nuclear Sampling Sys Valves 9398A (B) Failed to Close within Required Isolation Time Identified in Surveillance Requirement 4.6.4.3.Caused by Crud Buildup on Valve Seats.Crud Buildup Dislodged (← links)
- 05000395/LER-1982-066-03, /03L-0:on 821226,during Mode 1 Operation,Reactor Bldg Sump Leakage Detection Sys Declared Inoperable When High Level Alarm Remained in Alarm State.Caused by Failure of Capacitance Level Detection Sys.Sys Recalibr (← links)
- 05000395/LER-1982-063-03, /03L-0:on 821220,isotopic Iodine Analysis Not Performed within 6 H After Plant Went from 5% to 21% Thermal Power within 1 H.Caused by Failure to Notify Chemistry Dept to Perform Analysis.Procedure Developed (← links)
- 05000395/LER-1982-062-03, /03L-0:on 821220,seismic Switch YM-1782 Found to Have out-of-tolerance Trip Point on Transverse Sensor. Caused by Setpoint Drift on Horizontal Transverse Sensor. Switch Calibr & Returned to Svc (← links)
- 05000395/LER-1982-003-03, /03L-0:on 820820,isolation Valve in Fire Svc Sys Found Closed,Rendering Fire Suppression Sys Inoperable for Control Bldg Cable Spreading Rooms & Chases.Caused by Header Valve Being Tagged Prior to Entering Mode 6 (← links)
- 05000395/LER-1982-061-03, /03L-0:on 821218,diesel Generator B (XEG001B) Failed Monthly Operability Test by Tripping on Low Lube Oil Pressure.Cause Unknown.Diesel Generator B Satisfactorily Restarted within 30 Minutes (← links)
- 05000395/LER-1982-044-01, /01T-0:on 821202,surveillance Test Performed on 821005 for RHR Pump a Signed Off Approved When Acceptance Criteria Not Met.Caused by Personnel Error Due to Lack of Experience (← links)
- 05000395/LER-1982-045-03, /03L-0:on 821116,plant Entered Mode 1 W/O Performing Surveillance Test Procedure 134.001 Re Shutdown Margin Calculation Per Tech Specs.Caused by Personnel Oversight.Tech Specs Reviewed.Surveillance Program Revised (← links)
- 05000395/LER-1982-046-03, /03L-0:on 821117,main Control Board Indication for Steam Generator Feedwater Flow Read Zero.Caused by Personnel Leaving Equalizing Valves on Transmitters Open.Valves Closed & Personnel Indoctrinated (← links)
- 05000395/LER-1982-048-03, /03L-0:on 821117,condensate Polisher Backwash Water Released to Site Settling Ponds W/O Sampling.Caused by Inadequate Procedures for Release Process.Station Order Generated to Address Group Interface Prior to Release (← links)
- 05000395/LER-1982-047-03, /03L-0:on 821118,operations Personnel Failed to Document Tavg on 30-minute Basis Greater than 551 Degrees w/Tavg-Tref Deviation Alarm Not Reset.Caused by Failure of Operator to Recognize Surveillance Requirements (← links)
- 05000395/LER-1982-049-03, /03L-0:on 821118,Surveillance Requirement 4.7.9.1.1(e) Not Performed on Fire Suppression Water Sys. Caused by Fire Protection Group Being Unaware of Mode 6 Restriction.Personnel Counseled & Tracking Program Updated (← links)
- 05000395/LER-1982-043-03, /03L-0:on 821113,nuclear Instrumentation Power Range Channel (N42) low-range Trip Setpoint Found Set at 50% Instead of 25% of Rated Thermal Power.Caused by Personnel error.Low-range Trip Setpoint Reset (← links)
- 05000395/LER-1982-042-03, /03L-0:on 821110,RCS Temp Average Decreased When Control Rods Inserted.Caused by Simultaneous Rod Insertion & Main Steam Dumping.Control Rods Withdrawn & Steam Dump Isolated to Recover Temp Average (← links)
- 05000395/LER-1982-041-03, /03L-0:on 821109,during Mode 2,radiation Monitor RM-A1 (Control Room Isolation) Failed Surveillance Test Procedure 360.032.Caused by Instrument Drift.Monitor Calibr & Returned to Svc (← links)
- 05000395/LER-1982-039-03, /03L-0:on 821108,steam Generator Steam Flow Transmitter (FT-476) Power Supply Found Defective.Caused by Failure on Transmitter Power Supply (FQY-476).Channel Placed in Tripped Condition.Circuit Board Replaced & Tested (← links)
- 05000395/LER-1982-040-03, /03L-0:on 821108,Tech Spec 3.3.2 Had Not Been Complied W/Due to Improper Interpretation.Caused by Personnel Error.Ltr Issued Delineating Correct Interpretation of Tech Spec (← links)
- 05000395/LER-1982-038-03, /03L-0:on 821114,main Control Board Indication for Steam Generator a Steam Flow (FT-474) Failed to Indicate Sys Flow.Caused by Indicator Needle Sticking to Lower Stop. Channel Calibr Performed (← links)
- 05000395/LER-1982-034-03, /03L-0:on 821103,during Mode 4,radiation Monitor RM-G19C (Main Steam Line C Monitor) Failed to High Radiation Alarm Setpoint.Caused by Moisture Penetration of Cable Connectors Between Detector & Preamp.Detector Replaced (← links)
- 05000395/LER-1982-036-03, /03L-0:on 821103,plant Entered Mode 3 W/Control Room Evacuation Panel Pressurizer Relief Tank Level Indicator LI-470A Inoperable.Caused by Level Transmitter Being Out of Calibr.Transmitter Calibr (← links)
- 05000395/LER-1982-027-03, /03L-0:on 821022,plant Entered Mode 2 for Initial Criticality W/One of Two Containment Hydrogen Monitors Inoperable.Caused by Inoperable Detector Cell in Containment Hydrogen Monitor B.Cell Replaced (← links)
- 05000395/LER-1982-028-03, /03L-0:on 821022,Mode 2 Entered for Initial Criticality W/Loose Parts Monitoring Sys Inoperable.Caused by Mods Being Performed on Sys Before Applicable Surveillances Performed.Mods Completed (← links)
- 05000395/LER-1982-026-03, /03L-0:on 821019,operator Noticed Frequent Auto Reactor Coolant Makeup to Vol Control Tank of Chemical Vol & Control Sys.Caused by Cracked Safety Injection Filter B Vent Valve.Leak Test Performed W/Results of 12 Gpm (← links)
- 05000395/LER-1982-025-03, /03L-0:on 821020,during Performance of Surveillance Test Procedure,Porv PCV-445A Found Leaking. Caused by Degraded Seat/Disk Interface Due to Steam Impingement.Valves Will Be Repaired (← links)
- 05000395/LER-1982-020-03, /03L-0:on 821011,reactor Bldg Base Mat Seismic Monitoring Instrument IYA-1780 Tested Unsatisfactorily. Caused by Battery Charger Failure Resulting in Battery Discharge.Battery Replaced & Surveillance Performed (← links)
- 05000395/LER-1982-021-03, /03L-0:on 821011,steam Line Pressure Dropped Below Tech Spec Min.Caused by Safety Valve 2806P Inadvertently Lifting After Being Freed from stuck-closed Position.Valve & Power Range Neutron Flux High Setpoint Reset (← links)
- 05000395/LER-1982-017-03, /03L-0:on 821006,controlled Leakage Exceeded Tech Specs During Surveillance Test Procedure.Caused by Improperly Set Needle Valves Located in Reactor Coolant Pump Seal Injection Line.Valves Positioned Correctly (← links)
- 05000395/LER-1982-014-03, /03L-0:on 821002,air Pressure Equalizing Valves Would Not Cycle in Proper Sequence,Rendering Reactor Bldg Airlock Inoperable.Caused by Chain Drive Sprocket Shearing Key,Allowing Sprocket to Slip Into Associated Drive Shaft (← links)
- 05000395/LER-1982-010-03, /03L-0:on 821001,PORV Block Valve MVG-8000A Would Not Reopen at Conclusion of Reactor Vessel O-ring Leak Test. Caused by Wear in Valve Stem Packing Which Contributed to Overtorque Condition.Stem Packing Replaced (← links)
- 05000395/LER-1982-012-03, /03L-0:on 820928,reactor Bldg high-range Radiation Monitor RM-G7 Had Problems W/Spiking That Caused High Radiation Alarms.Spikes Caused by Electrical Interference in Detection Cable.Monitor Tested & Returned to Svc (← links)
- 05000395/LER-1982-011-03, /03L-0:on 820930,Mode 3 Entered W/Pressurizer Relief Tank Level Indication LI-470A Inoperable at Control Room Evacuation Panel.Caused by Transmitter Not Calibr Properly,Due to Defective Amplifier & Calibr Circuit Card (← links)
- 05000395/LER-1982-013-03, /03L-0:on 821001,differential Pressure Level Transmitter Accumulator Tank a Level Found Below Tech Specs by Approx 7% Following Recalibr.Caused by Transmitter Showing Incorrect Level Indication.Transmitter Recalibr (← links)
- 05000395/LER-1982-007-03, /03L-0:on 820925,diesel Generator Bldg Preaction Sprinkler Sys Heat Detectors Failed to Actuate Sprinkler Valve.Caused by Degraded Circuit Card in Sprinkler Sys Control Cabinet.Card Replaced (← links)
- 05000395/LER-1982-006-03, /03L-0:on 820922,several High Range Monitors Failed High.Caused by Moisture Accumulation in Detector Preamp Connections.Plant Completed Initial Fuel Load But Was Not Critical.Monitors Replaced Except RM-G19B (← links)
- 05000395/LER-1982-004-03, /03L-0:on 820915,test Signal Generated Causing B Train RHR Header Isolation Valve to Shut & Isolate Suction. Pump Manually Tripped.Surveillance Test Procedure Revised to Line Up Alternate RHR Train W/Valve Locked Out (← links)
- 05000395/LER-1982-005-03, /03L-0:on 820916,five Smoke Detectors at 400-ft & 412-ft Elevations of Control Bldg Disabled,Rendering Preaction Sprinkler Sys Automatic Actuation Capability Inoperable.Caused by Need to Perform Welding in 400-ft Area (← links)
- 05000395/LER-1982-002-03, /03L-0:on 820818,after Calibr Pressure Transmitter for RHR Train a Suction Isolation Valve,Valve Operator re-energized & Suction Isolation Valve Shut.Caused by Switch Being Left in Test Position.Personnel Reinstructed (← links)
- 05000395/LER-1982-055-03, /03L-0:on 821208,while in Mode 1,reactor Operators Noticed Frequent Auto Makeup to Rcs.Caused by Leaking Seal Injection Filter Drain Valve XVT-8386B.Second Isolation Valve in Series Installed in Drain Line (← links)
- 05000395/LER-1982-054-03, /03L-0:on 821208,loose Part Detection Sys Failed Daily Channel Check.Caused by Microprocessor Failure. Microprocessor Replaced (← links)
- 05000395/LER-1982-052-03, /03L-0:on 821204,during Mode 1,main Steam Line a Radiation Monitor RM-G19A Gave Spurious Alarms.Caused by Instrument Drift.Monitor Calibr & Returned to Svc (← links)
- 05000395/LER-1982-051-03, /03L-0:on 821202,Sys Test Procedure 145.002 Unsatisfactorily Performed on Waste Evaporator.Caused by Thermal Cut Out Switch Being Disconnected from Evaporator Distillate Pump Junction Box.Switch Replaced (← links)
- 05000395/LER-1982-001-03, /03L-0:on 820813,while Performing Test on Feeder Breaker for Control Room Train B Normal Ventilation Fan, Breaker Would Not Manually Reset.Caused by Random Failure of Square D Breaker (Fhl 36050-15M).Breaker Replaced (← links)
- 05000395/LER-1982-065-03, /03L-0:on 821222,electrical Power Lost to Train a Radiation Monitoring Sys.During Investigation of Loss of Power,Maint Personnel Accidently Short Circuited Train B. Caused by Blown Power Fuses Due to Personnel Error (← links)
- 05000395/LER-1982-059-03, /03L-0:on 821215,w/plant in Mode 1,several Fire Doors Not Verified Closed.Caused by Doors Not Being Included in Auxiliary Operator Logs Rev & Therefore Not Checked.Log Being Revised to Ensure That Doors Checked (← links)
- 05000395/LER-1982-059, Forwards LER 82-059/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-016, Forwards Revised LER 82-016/03L-2.Detailed Event Analysis Encl (redirect page) (← links)
- ML20028E125 (redirect page) (← links)
- 05000395/LER-1982-057-03, /03L-0:on 821213,turbine Bldg Sump Normal Discharge to Site Settling Ponds Temporarily Bypassed Via Auxiliary Pump & Fire Hose.Caused by Sump Pumps Becoming Clogged W/Debris from Const Repair Work Being Done (← links)
- 05000395/LER-1982-057, Forwards LER 82-057/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-058-03, /03L-0:on 821214,urgent Failure Alarm Due to Loss of Power Occurred During Restoration of Rod Control Sys Upon Completion of Power Operational Testing.Caused by Oxidation Between Fuse & Fuse Block Mating Surfaces (← links)
- 05000395/LER-1982-058, Forwards LER 82-058/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-060-03, /03L-0:on 821215,Surveillance Requirement 4.3.3.6 Discovered Unperformed in Modes 1,2 & 3.Caused by Personnel Error.Procedure Revised (← links)
- 05000395/LER-1982-060, Forwards LER 82-060/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-056-03, /03L-0:on 821209,surveillance Test Procedure, Nis Power Range Heat Balance, Not Performed in Specified Intervals.Caused by Personnel Oversight.Administrative Procedures for Control of Surveillances Revised (← links)
- 05000395/LER-1982-056, Forwards LER 82-056/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-053-03, /03L-0:on 821206,during Mode 1,spurious High & Low Meter Indications Observed on Main Control Board Indicator FI-494 for Steam Generator C Flow.Caused by Failure of Circuit Board FY-494.Board Replaced (← links)
- 05000395/LER-1982-053, Forwards LER 82-053/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-032-03, /03L-0:on 821029,auxiliary Operator Discovered Nuclear Blowdown Monitor Tank Damaged.Caused by Distorted Diaphragm Blocking Tank Overflow & Vent Paths.Diaphragm Removed & Tank Repaired (← links)
- 05000395/LER-1982-029-03, /03L-0:on 821025,during Zero Power Testing, Isolation Amplifier Resistor Input on Power Range Channel NI-44 Found Out of Calibr Tolerance.Caused by Instrument Drift.Channel Removed from Svc & Calibr (← links)
- 05000395/LER-1982-029, Forwards LER 82-029/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-032, Forwards LER 82-032/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-031-03, /03L-0:on 821030,w/plant in Mode 4,source Range Channel NI-32 Failed Low.Caused by Loose Connection on Dry Bulb Voltage Attenuator Connector.Connection Repaired & Channel Operable by 821101 (← links)
- 05000395/LER-1982-031, Forwards LER 82-031/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-030-03, /03L-0:on 821028,in Mode 2,svc Water Booster Pump Discharge Check Valve XVC-3135B Found Stuck in Closed Position.Valve Disassembled,Inspected,Lubricated,Reassembled & Tested Satisfactorily (← links)
- 05000395/LER-1982-030, Forwards LER 82-030/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-033-03, /03L-0:on 821031,during Water Pump Test,Speed Switch XES-2003A Failed in Midposition During Fast to Slow Speed Transfer,Rendering Svc Water Train a Inoperable.Caused by Bad Relay Contact on Speed Switch.Relay Repaired (← links)
- 05000395/LER-1982-033, Forwards LER 82-033/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-024-03, /03L-0:on 821018,plant Went Into Mode 4 W/O Performing Surveillance Test Procedure 114.002, Operational Leak Test. Caused by Procedural Inadequacies.Procedure Revised to Comply W/Tech Spec Requirements (← links)
- 05000395/LER-1982-024, Forwards LER 82-024/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-022-03, /03L-0:on 821012,circuit Breaker for Reactor Bldg Cooling Unit Fan XFN-62B Discovered Open & in Discharged Position.Cause Undetermined.All 480-volt Safeguard Switchgear Checked.Procedures Revised to Verify Position (← links)
- 05000395/LER-1982-022, Forwards LER 82-022/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-019-03, /03L-0:on 821010,during Initial Startup in Mode 3, Pressurizer PORV Block Valve Mvg 8000C in RCS Found Leaking in Open Position.Caused by Worn Valve Packing.Packing Replaced.Valve Tested & Returned to Operable Status (← links)
- 05000395/LER-1982-019, Forwards LER 82-019/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-023-03, /03L-0:on 821014,while in Mode 3,B Train Control Room Ventilation Sys Declared Inoperable for Maint Due to Failure of Pressure Regulator for Damper Actuator.Caused by Ruptured Regulator Diaphragm.Diaphragm Replaced (← links)
- 05000395/LER-1982-023, Forwards LER 82-023/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-015-03, /03L-0:on 821003,sample Pumps on Reactor Bldg Air Sample Radiation Monitor RMA-2 Tripped Due to Overheating in Cabinet.Caused by Inadequate Cabinet Ventilation.Pumps Cooled & Restarted After Approx 4-h (← links)
- 05000395/LER-1982-015, Forwards LER 82-015/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-018-03, /03L-0:on 821008,during Surveillance Test Procedure 303.006,pressure Bistable Failed to Change Output State.Caused by Failure of Printed Circuit Logic Card.Card Replaced & Test Procedure Performed Satisfactorily (← links)
- 05000395/LER-1982-018, Forwards LER 82-018/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-009-03, /03L-0:on 820929,Surveillance Test Procedure 128.007 Performed Instead of 128.017 Which Implements Tech Spec to Verify Position of Locked Closed Fire Doors.Caused by Personnel/Numerical Error.Personnel Counseled (← links)
- 05000395/LER-1982-009, Forwards LER 82-009/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1982-008-03, /03L-0:on 820929,svc Water Pond Level Indication Not Verified for Modes 1,2,3 & 4 from 820922-29.Caused by Pond Level Entry Omitted from Operator Logs Due to Personnel Error.Logs Reviewed & Revised (← links)
- 05000395/LER-1982-008, Forwards LER 82-008/03L-0.Detailed Event Analysis Encl (← links)
- ML20027D940 (redirect page) (← links)