Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20095L530 + (NPDES Noncompliance Rept:On 840801-02,unit Operated W/Less than Two Fine Mesh Screens.Caused by Clogging of Circulating Water Pump by Marine Growth & Back pressure-induced Trip Due to Impinged Jellyfish.Bar Rack Replaced & Screens Cleaned)
- ML20127M657 + (NPDES Noncompliance Rept:On 850418,biological Oxygen Demand of Sample from Discharge Point 108 in Sewage Treatment Plant Exceeded Permit Limit.Caused by Pin Floc Carryover from Clarifier.Pressure Filters Utilized)
- ML20066K577 + (NPDES Noncompliance notification:58,330 Gallons of 25.3 Mg Iron Concentration Waste Discharged on 821020.Caused by Addition of Const Wastes.Mod Initiated to Provide Option for Treatment of Tanks)
- ML20114C762 + (NPDES Noncompliance notification:841227 Iron Concentration in Effluent Sample 3.1 Ppm,Exceeding 1.0 Ppm Max Daily Limit.Caused When Heating Boiler Drained Into Lake)
- ML17334B757 + (NPDES Noncompliance notification:980327,boiler Condensate Spill Occurred.Caused by Small Amount of Condensate on Metal Skirting Surrounding Containment Berm.Failed Condensate Valve Was Replaced)
- ML20064D086 + (NPDES Noncompliance on 781020,6,500 Gallons of Water Containing Ph of 10.5 Discharged,Exceeding Permit Limit of 6-9.0.Caused by air-operated Valve Failing in Open Position)
- ML20023D865 + (NPDES Noncompliance:On 830525,daily Max Ph Effluent Limit Exceeded.Util Commenced Investigation of Incident.Ltr to Be Sent to Dept of Natural Resources Outlining Results & Corrective Action)
- ML20101G729 + (NPDES Noncompliance:On 841129 Weekly Analysis of Discharge Point 001 Showed Oil & Grease Concentration Above Tech Spec Limits.Caused by Large Amount of Oil in Turbine Bldg Sump. Sump Pump Shut Off & Sump Pumped Out)
- RBG-30513, NPDES Noncompliance:On 890406,effluent Limitations for Total Residual Chlorine in Outfall 004 Exceeded Permit Limits. Caused by Inability to Adjust Chlorine Dosage within Fluctuating Flow & Oxidant Demand + (NPDES Noncompliance:On 890406,effluent Limitations for Total Residual Chlorine in Outfall 004 Exceeded Permit Limits. Caused by Inability to Adjust Chlorine Dosage within Fluctuating Flow & Oxidant Demand)
- ML20069N421 + (NPDES Noncompliance:On 940501,oil Discharged from Hydraulic Oil Reservoir Below Lake Anna Main Dam.Caused by Worn o-ring in Inlet Valve Key Lock Switch.Switch Replaced & All Hose Replaced.Listed Options Being Evaluated)
- ML20065B922 + (NPDES Noncompliances Notification:On 940204,discharge 001 Maximum Daily Limit of 1.0 mg/1 Total Zinc Was Exceeded. Caused by Low Ph Transient in Unit 2 Cooling Tower Water Sys.Isolated Acid Injection Sys)
- ML20042D389 + (NPDES Notification Re 891227 Oil Spill.Caused by Hydraulic Overflow of Oil Separation Unit Which Drains Into Station Cooling Water Discharge Canal.Cleanup of Oil Using Absorbent Matl Began Following Discovery & Confirmation of Spill)
- ML20236S660 + (NPDES Notification of Wastewater Discharge Permit Violation: on 980623,Rancho Seco Laboratory Records Indicate Combined Plant Effluent Ph Greater than Supply Water Ph.Caused by Improper Reporting of Ph Values.Reviewing Existing Methods)
- ML18344A428 + (NPDES Notification, Incident No. PAL-90-11-NCFD1)
- ML20265B029 + (NPDES Outfalls Receiving Streams Map)
- ML20138R468 + (NPDES Permit 3IB00016 Cd,Issued to Cleveland Electric Illuminating Co)
- ML20134M134 + (NPDES Permit 3IB00016*ED,issued to Oh EPA)
- ML20058L666 + (NPDES Permit 5633,issued to Monticello Nuclear Generating Plant,Northern States Power Co)
- ML20065D667 + (NPDES Permit AL0024619,issued to Alabama Power Co Farley Nuclear Plant)
- ML20101H179 + (NPDES Permit AL0024619,issued to Southern Nuclear Operating Co Farley Nuclear Plant)
- ML20010B560 + (NPDES Permit AR 0009920,issued to AR Power & Light Co)
- ML20080P304 + (NPDES Permit AR0001392,issued to Arkansas Power & Light Co)
- HNP-14-064, NPDES Permit Application Amendment Request + (NPDES Permit Application Amendment Request)
- HNP-12-029, NPDES Permit Application Modification Request + (NPDES Permit Application Modification Request)
- ML20148R825 + (NPDES Permit CA0001228, Monitoring & Reporting Program 88-001, Issued to Southern California Edison Co)
- CY-05-080, NPDES Permit CT0003123 Renewal Application + (NPDES Permit CT0003123 Renewal Application)
- ML20126M600 + (NPDES Permit CT0003263,issued to Northeast Nuclear Energy Company)
- ML030300754 + (NPDES Permit December 2002)
- ML19268A327 + (NPDES Permit FL0000159,issued to Fl Power Corp)
- ML17273A043 + (NPDES Permit Fl 0002208,issued to Fl Power & Light)
- ML20211N637 + (NPDES Permit GA0004120,issued to Southern Nuclear Operating Co)
- ML20238E310 + (NPDES Permit Ga 0004120,issued to Georgia Power Co)
- ML20248B100 + (NPDES Permit Ga 0026786 Issued to Georgia Power Co)
- ML20128F639 + (NPDES Permit I-NE07-P002,issued to Kansas Gas & Electric Co)
- ML20237C931 + (NPDES Permit IL0036919,issued to Illinois Power Co)
- ML20141F236 + (NPDES Permit IL0048151,issued to Comm Ed)
- ML20037B614 + (NPDES Permit Il 0002224,issued to Comm Ed)
- ML061000537 + (NPDES Permit Implementation and Control Procedure Number 36001-C Rev 31)
- ML20198J496 + (NPDES Permit KS-0079057,issued to Wolf Creek Nuclear Operating Corp)
- ML20235T433 + (NPDES Permit KS-0079057,issued to Wolf Creek Nuclear Operation Corp)
- ML20137C139 + (NPDES Permit LA0042731,issued to Gulf States Utils Co)
- ML20151R411 + (NPDES Permit MD0002399,issued to Bg&E)
- ML20195J660 + (NPDES Permit MD0002399,issued to Bg&E)
- ML20059A157 + (NPDES Permit MI0037028,issued to Michigan Water Resources Commission)
- ML20148H953 + (NPDES Permit MO-0098001 Issued to Union Electric Co)
- ML20091A369 + (NPDES Permit MO-0098001,issued to Union Electric Co)
- ML20138M327 + (NPDES Permit MO-0098001,issued to Union Electric Co)
- ML20073Q121 + (NPDES Permit Ma 0003557 Issued to Boston Edison Co)
- ML17325A079 + (NPDES Permit Mi 0005827,issued to Indiana & Michigan Electric Co.Mod Authorizes Discharge of make-up Plant Prefilter Backwash Water to Lake Michigan)
- ML17318A681 + (NPDES Permit Mi 0005827,issued to in & Mi Power Co)
- ML20132D363 + (NPDES Permit Mi 0039110,issued to Detroit Edison Co)