- ML17348A281 + (15:12:52, 7 January 2025)
- ML17348A280 + (15:12:53, 7 January 2025)
- L-90-196, Forwards Emergency Power Sys Enhancement Project Repts, Reflecting Current Design Info + (15:12:54, 7 January 2025)
- ML17348A277 + (15:12:56, 7 January 2025)
- 05000250/LER-1989-020, :on 891223,reactor Trip Occurred Due to Closure of MSIV 4A.Caused by Corroded Terminal Board Installed in Incompatible Svc Environ.Procedures Revised to Improve Installation of Boxes + (15:12:57, 7 January 2025)
- ML17348A275 + (15:12:59, 7 January 2025)
- L-17-352, No Active Safety Function Anchor Darling Double Disc Gate Valves + (15:13:00, 7 January 2025)
- ML17348A273 + (15:13:01, 7 January 2025)
- ML17348A271 + (15:13:02, 7 January 2025)
- IR 05000250/1990012 + (15:13:09, 7 January 2025)
- ML17348A268 + (15:13:10, 7 January 2025)
- L-90-156, Forwards Relief Request 6/7 a from Code Requiring Volumetric & Visual Exam of Reactor Coolant Pump Casing Welds & Interior Surfaces.Approval Requested by 900915 to Facilitate Upcoming Outages Beginning Nov & Dec 1990 + (15:13:11, 7 January 2025)
- L-90-197, Forwards Update to 890310 Response to Generic Ltr 88-14, Instrument Air Supply Sys Problems Affecting Safety-Related Equipment. Sys Upgrade Sent Out for Equipment,Const & Engineering Estimates + (15:13:12, 7 January 2025)
- L-90-199, Submits Rept Detailing Investigative Analysis of Unsatisfactory Blind Specimen Results,Identification of Causes & Corrective Actions Taken by Lab to Prevent Recurrence,Per 10CFR26,App A.2.8(e)(4) + (15:13:14, 7 January 2025)
- 05000250/LER-1989-013, :on 890910,boric Acid Transfer (Bat) Pump Not Declared Out of Svc Prior to Refilling Seal Pot.Caused by Noncognitive Error by Util Maint Personnel.Bat Pump 3B Realigned + (15:13:17, 7 January 2025)
- L-90-179, Forwards Progress Summary of Select Sys Assessment for Apr 1990,per NRC 860812 order.Outage-related Mods Include Replacement of RHR Valve 887 & Completion of Installation of Redundant Air Start Motors on Emergency Diesel Generators + (15:13:17, 7 January 2025)
- 05000250/LER-1989-021, :on 890721,discrepancies in Process Control Program Identified.Caused by Document Not Specifying That Containers Must Be Among Those Listed in Process Control Program.Operating Procedure 11550.48 Revised + (15:13:20, 7 January 2025)
- ML17348A260 + (15:13:21, 7 January 2025)
- TAC:73215 + (15:13:22, 7 January 2025)
- ML17348A259 + (15:13:23, 7 January 2025)
- L-90-185, Special Rept:Fire Barriers & Other Fire Protection Sys Inoperable for Greater than 7 Days,Thus,Violating Tech Spec 3.14.5.b.Plant Continues to Implement Compensatory Measures as Applicable + (15:13:25, 7 January 2025)
- ML17348A258 + (15:13:25, 7 January 2025)
- ML17348A256 + (15:13:27, 7 January 2025)
- ML17348A254 + (15:13:28, 7 January 2025)
- L-90-184, Documents Written & Verbal Request for Temporary Waiver of Compliance from Tech Spec 3.4.5.b.2 Re Intake Cooling Water Pump 4B Replacement,Based on 900513 Reduction of Flow from Pump.Waiver Should Extend Until 900522 + (15:13:29, 7 January 2025)
- L-90-178, Monthly Operating Repts for Apr 1990 for Turkey Point,Units 2 & 3 + (15:13:33, 7 January 2025)
- ML17348A245 + (15:13:35, 7 January 2025)
- ML17348A244 + (15:13:37, 7 January 2025)
- ML17348A243 + (15:13:37, 7 January 2025)
- ML17348A241 + (15:13:38, 7 January 2025)
- L-90-163, Forwards Thimble Tube Eddy Current Insp Rept Re NRC Bulletin 88-009, Thimble Tube Thinning in Westinghouse Reactors. Insp Conducted at End of Cycle Xi.One Thimble Required to Be Isolated Until Wear Rate Determined + (15:13:39, 7 January 2025)
- 05000251/LER-1990-003-02, :on 900409,reactor Protection Sys Actuation Occurred Due to Failure of Reactor Coolant Pump Underfrequency Relay Power Supply Capacitor.Caused by Open Supply Breakers.Relay Replaced + (15:13:44, 7 January 2025)
- ML17348A237 + (15:13:46, 7 January 2025)
- L-90-164, Requests M Wagner Take Generic Fundamentals Exam Section of Operator Licensing Exam to Be Administered on 900606 + (15:13:47, 7 January 2025)
- 05000250/LER-1990-006, :on 900406,control Room Ventilation Sys for Common Control Room of Units Tripped While Performing Procedure TP-584.Caused by Personnel Error.Individual Counseled + (15:13:49, 7 January 2025)
- ML17348A232 + (15:13:50, 7 January 2025)
- ML17348A231 + (15:13:52, 7 January 2025)
- L-90-160, Provides Revised Response to Emergency Power Sys Enhancement Project,Per 900426 Discussion + (15:13:53, 7 January 2025)
- ML17348A228 + (15:13:53, 7 January 2025)
- 05000250/LER-1990-007, :on 900408,CCW Pump 3B Automatically Started Due to Low Pump Discharge Header Pressure.Caused by Inadequate Procedural Controls in Operating Surveillance Procedure 3-OSP-030.7.Procedures Changed + (15:13:56, 7 January 2025)
- ML17348A219 + (15:13:57, 7 January 2025)
- ML17348A218 + (15:13:59, 7 January 2025)
- ML17348A217 + (15:13:59, 7 January 2025)
- ML17348A215 + (15:14:00, 7 January 2025)
- IR 05000250/1990010 + (15:14:02, 7 January 2025)
- ML17348A212 + (15:14:03, 7 January 2025)
- ML17348A211 + (15:14:04, 7 January 2025)
- ML17348A210 + (15:14:05, 7 January 2025)
- L-90-137, Forwards Select Sys Assessment Progress Summary for Mar 1990,per 860812 Order + (15:14:06, 7 January 2025)
- 05000250/LER-1989-014, :on 890912,discovered That Component Cooling Water Flow Rate to Emergency Containment Coolers Below DBA Requirements.Caused by Inadequate Administrative Controls. Mechanical Stops Readjusted to Prior Setting + (15:14:08, 7 January 2025)
- ML17348A207 + (15:14:10, 7 January 2025)