- 05000311/LER-1981-005-03, /03L-0:on 810413,all Reactor Coolant & Residual Heat Removal Pumps Were de-energized Longer than Time Allowed by Tech Specs.Caused by Replacement of Relief Valve 2RH3 in Residual Heat Removal Sys + (10:06:43, 6 January 2025)
- 05000311/LER-1981-005, Forwards LER 81-005/03L-0.Detailed Event Analysis Encl + (10:06:45, 6 January 2025)
- ML18086A518 + (10:06:46, 6 January 2025)
- 05000272/LER-1981-007-03, /03X-2:on 800128,during Review of Sys Diagrams, Demineralized Water Supply Check Valve to Auxiliary Feedwater Storage Tank 1DR7 Found to Be Not Seismically Qualified.Caused by Design Deficiency.Valve Qualified + (10:06:48, 6 January 2025)
- 05000272/LER-1980-007, Forwards LER 80-007/03X-2.Detailed Event Analysis Encl + (10:06:49, 6 January 2025)
- ML18086A512 + (10:06:51, 6 January 2025)
- ML18086A510 + (10:06:52, 6 January 2025)
- 05000272/LER-1981-041-03, /03L-0:on 810426,while in Hot Standby,Action Statement 3.4.6.2 Entered Due to Unidentified RCS Leak. Cause Not Stated.Action Statement Terminated When Valve 1PS8 Was Discovered Leaking.Valve Repacked + (10:06:54, 6 January 2025)
- 05000272/LER-1981-041, Forwards LER 81-041/03L-0.Detailed Event Analysis Encl + (10:06:56, 6 January 2025)
- 05000311/LER-1981-007-03, /03L-0:on 810423,while Attempting to Start Auxiliary Feedwater Pump 22,relay Flags for Phases a & C on Breaker 2B1D Found Dropped.Caused by Drifting of Wipe on Trip Latch.Wipe of Trip Latch Reset + (10:06:58, 6 January 2025)
- 05000311/LER-1981-007, Forwards LER 81-007/03L-0.Detailed Event Analysis Encl + (10:07:00, 6 January 2025)
- ML18086A499 + (10:07:06, 6 January 2025)
- 05000272/LER-1981-039-01, /01T-0:on 810422,svc Water Leak Discovered Coming from Containment Fan Cooling Unit 13.Caused by Leak in Weld Connecting Carbon Steel Nipple to Stainless Steel Flange in Unit Outlet Drain Line.Weld Reworked + (10:07:08, 6 January 2025)
- 05000272/LER-1981-039, Forwards LER 81-039/01T-0.Detailed Event Analysis Encl + (10:07:09, 6 January 2025)
- NG-18-0036, Supplemental Information, Fifth Inservice Inspection Interval Program Plan, Relief Request RR-03 + (10:07:11, 6 January 2025)
- ML18086A494 + (10:07:16, 6 January 2025)
- ML18086A493 + (10:07:17, 6 January 2025)
- ML18086A491 + (10:07:18, 6 January 2025)
- ML18086A490 + (10:07:19, 6 January 2025)
- ML18086A488 + (10:07:21, 6 January 2025)
- ML18086A487 + (10:07:21, 6 January 2025)
- ML18086A485 + (10:07:23, 6 January 2025)
- 05000272/LER-1980-030-03, /03X-3:on 800601,fusible Plug for Battery Room Detectors Melted During Testing.Caused by Not Removing Hot Air Blower Quickly Enough.Detectors Replaced + (10:07:24, 6 January 2025)
- 05000272/LER-1980-030, Forwards LER 80-030/03X-3.Detailed Event Analysis Encl + (10:07:26, 6 January 2025)
- 05000272/LER-1981-018-03, /03X-1:on 810214,diesel Generator 1A Was Declared Inoperable Due to Cooling Water Leak.Caused by Cracked & Leaking Nipple Connecting Jacket Water Valve 1DA45A & Jacket Water Pipe.Nipple Replaced + (10:07:28, 6 January 2025)
- 05000272/LER-1981-018, Forwards LER 81-018/03X-1.Detailed Event Analysis Encl + (10:07:30, 6 January 2025)
- ML18086A478 + (10:07:33, 6 January 2025)
- ML18086A475 + (10:07:34, 6 January 2025)
- ML18086A476 + (10:07:34, 6 January 2025)
- ML18086A471 + (10:07:35, 6 January 2025)
- ML18086A470 + (10:07:36, 6 January 2025)
- IR 05000272/1980016 + (10:07:37, 6 January 2025)
- ML18086A464 + (10:07:39, 6 January 2025)
- ML18086A463 + (10:07:40, 6 January 2025)
- ML18086A461 + (10:07:40, 6 January 2025)
- ML18086A460 + (10:07:41, 6 January 2025)
- 05000272/LER-1981-038-03, /03L-0:on 810404,during Routine Testing,No Audible Fire Alarm Signals Were Generated.Caused by Out of Adjustment Limit Switch.Decoder & Limit Switch Readjusted, Cycled & Tested Satisfactorily + (10:07:43, 6 January 2025)
- 05000272/LER-1981-038, Forwards LER 81-038/03L-0 + (10:07:45, 6 January 2025)
- 05000272/LER-1981-036-03, /03L-0:on 810405,fire Hose Located on Elevation 100-ft Was Discovered to Be Inoperable Due to 6-inch Slash. Caused by Malicious Mischief or Vandalism by Unknown Person or Persons.Hose Replaced + (10:07:48, 6 January 2025)
- 05000272/LER-1981-036, Forwards LER 81-036/03L-0.Detailed Event Analysis Encl + (10:07:50, 6 January 2025)
- 05000272/LER-1981-037-03, /03L-0:on 810404,RHR Pump Declared Inoperable. Caused by Leak from Mechanical Seal.Shaft Sleeve O Rings, Throttle Bushing Assembly & Circulating Ring Assembly Replaced + (10:07:55, 6 January 2025)
- ML18086A452 + (10:07:56, 6 January 2025)
- 05000272/LER-1981-037, Forwards LER 81-037/03L-0 + (10:07:58, 6 January 2025)
- ML18086A446 + (10:08:00, 6 January 2025)
- ML18086A433 + (10:08:00, 6 January 2025)
- ML18086A425 + (10:08:02, 6 January 2025)
- ML18086A422 + (10:08:03, 6 January 2025)
- ML18086A416 + (10:08:04, 6 January 2025)
- IR 05000272/1981004 + (10:08:13, 6 January 2025)
- ML18086A406 + (10:08:15, 6 January 2025)
- ML18086A397 + (10:08:16, 6 January 2025)