Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18113A874 + (04:38:24, 6 January 2025)
- ML18113A872 + (04:38:25, 6 January 2025)
- ML18113A870 + (04:38:26, 6 January 2025)
- 05000281/LER-1978-038-03, /03X-1 on 781030:boric Acid Flow from Boric Acid Tank to Blender Was Interrupted.Caused by Blockage of Crystallized Boron at Elbow in Line 1-CH-356-152 + (04:38:28, 6 January 2025)
- 05000281/LER-1978-033-03, /03X-1 on 780926:circulating Water Outlet Valve MOV-CW-200D Failed to Close When Operated Electrically. Caused When Actuator Cam for Shut Torque Switch Became Wedged Against Torque Switch Hold Down Screw + (04:38:30, 6 January 2025)
- ML18113A866 + (04:38:31, 6 January 2025)
- ML18113A865 + (04:38:32, 6 January 2025)
- 05000280/LER-1978-047-03, /03X-1 on 781211:primary to Secondary Leakage in C Steam Generator Exceeded Allowable Limit.Caused by Leakage Through Five Steam Generator Tubes,Combined Flow Resulted in Excessive Leakage + (04:38:33, 6 January 2025)
- 05000280/LER-1978-047, Forwards LER 78-047/03X-1 + (04:38:35, 6 January 2025)
- 05000280/LER-1979-003-03, /03L-0 on 790124:error Detected in Calibr Procedures for Steam Flow Instrumentation.Caused by Error Made When Calibr Procedures Changed + (04:38:37, 6 January 2025)
- 05000280/LER-1979-003, Forwards LER 79-003/03L-0 + (04:38:39, 6 January 2025)
- 05000281/LER-1979-004-03, /03L-0 on 790204:setpoints of Seven Main Steam Safety Valves Not within Tech Spec Limits.Caused by Normal Setpoint Drift + (04:38:41, 6 January 2025)
- 05000281/LER-1979-004, Forwards LER 79-004/03L-0 + (04:38:43, 6 January 2025)
- ML18113A852 + (04:38:45, 6 January 2025)
- 05000281/LER-1979-003-03, /03L-0 on 790122: Following Containment Entrance Equipment Hatch Escape Airlock,Outer Door Was Not Proven Sealed within 72-h from Initial Opening.Caused by Problems in Sealing Exterior Hatch + (04:38:46, 6 January 2025)
- 05000281/LER-1979-002-03, /03L-0 on 790120: During Normal Operation Channel Check Revealed That Pressurizer Pressure Channel I Drifted Above Tech Spec Limit as Compared to Channels II & Iii. Caused by Failure of Channel I Pressure Transmitter + (04:38:48, 6 January 2025)
- 05000281/LER-1979-002, Forwards LER 79-002/03L-0 & 79-003/03L-0 + (04:38:50, 6 January 2025)
- ML18113A847 + (04:38:51, 6 January 2025)
- ML18113A846 + (04:38:52, 6 January 2025)
- ML18113A845 + (04:38:52, 6 January 2025)
- ML18113A844 + (04:38:53, 6 January 2025)
- ML18113A843 + (04:38:54, 6 January 2025)
- ML18113A842 + (04:38:55, 6 January 2025)
- ML18113A839 + (04:38:56, 6 January 2025)
- ML18113A840 + (04:38:56, 6 January 2025)
- 05000280/LER-1979-002-03, /03L-0 on 790115:electrical Penetration Between Turbine Bldg & Emergency Switchgear Room Not Properly Sealed.Caused by Penetration Being Broken During Previous Implementation of Design Change + (04:38:58, 6 January 2025)
- 05000280/LER-1979-002, Forwards LER 79-002/03L-0 + (04:39:00, 6 January 2025)
- ML18113A835 + (04:39:01, 6 January 2025)
- 05000281/LER-1979-001-03, /03L-0 on 790112:personnel Batch Inner Door & Emergency Escape Manway Not Leak Tested within 72-h After Opening Because Escape Manway Safety Lock Believed Broken, Posing Hazard + (04:39:03, 6 January 2025)
- 05000281/LER-1979-001, Forwards LER 79-001/03L-0 + (04:39:05, 6 January 2025)
- ML18113A831 + (04:39:06, 6 January 2025)
- ML18113A830 + (04:39:07, 6 January 2025)
- ML18113A827 + (04:39:08, 6 January 2025)
- ML18113A826 + (04:39:09, 6 January 2025)
- ML18113A825 + (04:39:09, 6 January 2025)
- ML18113A824 + (04:39:10, 6 January 2025)
- ML18113A823 + (04:39:11, 6 January 2025)
- IR 05000280/1978034 + (04:39:12, 6 January 2025)
- ML18113A820 + (04:39:14, 6 January 2025)
- 05000280/LER-1978-038-03, /03X-1 on 781108:review of Operational Data Showed That Quarterly Calibr of Nuclear Power Range Instrumentation Had Not Been Performed Per Schedule,Due to Scheduling Error + (04:39:15, 6 January 2025)
- 05000280/LER-1978-031-03, /03X-1 on 781001:during Normal Operation,Channel I Pressurizer Level (Protection) L-I-459 Drifted High.Caused by Drift of Electronic Zero Adjustment,In Conjunction W/ Leakage Thru Transmitter Bypass/Equalizing Valve + (04:39:17, 6 January 2025)
- 05000280/LER-1978-031, Forwards LER 78-031/03X-1 & 78-038/03X-1 + (04:39:19, 6 January 2025)
- ML18113A815 + (04:39:21, 6 January 2025)
- 05000280/LER-1978-041-03, /03X-1 on 781121:during Performance of PT-39-1 at Full Power,Snubber 1-WAPD-HSS-141B Had 0 Fluid Level in Reservoir,Due to Crack in Reservoir Glass + (04:39:22, 6 January 2025)
- 05000280/LER-1978-041, Forwards LER 78-041/03X-1 + (04:39:24, 6 January 2025)
- ML18113A807 + (04:39:25, 6 January 2025)
- IR 05000280/1978033 + (04:39:27, 6 January 2025)
- ML18113A801 + (04:39:32, 6 January 2025)
- ML18113A802 + (04:39:32, 6 January 2025)
- ML18113A799 + (04:39:33, 6 January 2025)
- ML18113A795 + (04:39:34, 6 January 2025)