Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19262C047 + (14:08:11, 3 January 2025)
- ML19262C046 + (14:08:13, 3 January 2025)
- ML19262C045 + (14:08:15, 3 January 2025)
- ML19262C044 + (14:08:16, 3 January 2025)
- ML19262C043 + (14:08:18, 3 January 2025)
- ML19262C042 + (14:08:19, 3 January 2025)
- ML19262C040 + (14:08:20, 3 January 2025)
- ML19262C039 + (14:08:22, 3 January 2025)
- ML19262C038 + (14:08:24, 3 January 2025)
- ML19262C037 + (14:08:26, 3 January 2025)
- ML19262C035 + (14:08:28, 3 January 2025)
- ML19262C034 + (14:08:29, 3 January 2025)
- ML19262C033 + (14:08:30, 3 January 2025)
- ML19262C032 + (14:08:31, 3 January 2025)
- ML19262C031 + (14:08:33, 3 January 2025)
- ML19262C030 + (14:08:35, 3 January 2025)
- 05000309/LER-1979-026-03, During Emergency Diesel Generator Test,Diesel Generator Turbocharger Failed.Fire Started within Engine Exhaust Sys & Engine Shut Down.Caused by Thrust Bearing Failure.Bearing Replaced + (14:08:38, 3 January 2025)
- 05000309/LER-1979-026, Forwards Updated LER 79-026/03X-1 + (14:08:45, 3 January 2025)
- 05000213/LER-1980-001-01, /01T-0:on 800103,during Routine Operability Verification Test,Timer for Containment Air Recirculation Fan F 17-3 Failed to Meet Tech Spec Limits.Caused by Four Timers Having Premature time-out Condition.Units Cleaned + (14:08:50, 3 January 2025)
- 05000213/LER-1980-001, Forwards LER 80-001/01T-0 + (14:08:55, 3 January 2025)
- 05000333/LER-1979-117-03, /03L-0:on 791227,during Preparation for Reactor Startup,Average Power Range Monitor Channel D Scram Trip Setpoint Was Found Set at 23%,compared to Tech Spec Limit of 15%.Caused by Instrument Drift of 15% Trip Point + (14:09:27, 3 January 2025)
- 05000333/LER-1979-117, Forwards LER 79-117/03L-0 + (14:09:52, 3 January 2025)
- ML19262C020 + (14:09:55, 3 January 2025)
- ML19262C019 + (14:09:56, 3 January 2025)
- 05000325/LER-1979-117-03, /03L-0:on 791222,during Normal Operation, Containment Atmospheric Monitor Was Registering Approx 1% Below Actual Drywell Oxygen Concentration.Caused by Faulty Analyzer Calibr.Analyzer Recalibr + (14:10:29, 3 January 2025)
- 05000325/LER-1979-117, Forwards LER 79-117/03L-0 + (14:10:45, 3 January 2025)
- 05000325/LER-1979-110-03, /03L-0:on 791218,while Performing Reactor Vessel Shroud Calibr,Switch 1 on 1-B21-LITS-N037 Was Found Out of Calibr.Caused by Bump from Nearby Scaffolding or by Calibr of Brooks Converter.Switch Was Recalibr + (14:10:50, 3 January 2025)
- 05000325/LER-1979-110, Forwards LER 79-110/03L-0 + (14:10:56, 3 January 2025)
- ML19262C010 + (14:11:00, 3 January 2025)
- 05000324/LER-1979-097-03, /03L-0:on 791217,during Normal Plant Operation, torus-to-drywell Vacuum Breaker CAC-X18E Had No Closed Indication.Caused by Valve Flapper Not Completely Closing. Replaced Permanent Magnet Holding Flapper Closed + (14:11:03, 3 January 2025)
- ML19262C008 + (14:11:06, 3 January 2025)
- 05000324/LER-1979-097, Forwards LER 79-097/03L-0 + (14:11:09, 3 January 2025)
- ML19262C004 + (14:11:11, 3 January 2025)
- ML19262C003 + (14:11:12, 3 January 2025)
- ML19262C002 + (14:11:14, 3 January 2025)
- 05000313/LER-1979-023-03, /03L-0:on 791221,during Normal Makeup Operation, Boric Acid Pumps Left Operating,Resulting in Overboration of Reactor Coolant & Automatic Withdrawal of Rod.Caused by Reactor Operator Oversight.Operator Counseled + (14:11:16, 3 January 2025)
- ML19262C000 + (14:11:19, 3 January 2025)
- 05000313/LER-1979-023, Forwards LER 79-023/03L-0 + (14:11:21, 3 January 2025)
- 05000348/LER-1979-066-03, /03L-0:on 791220,while Performing Surveillance One Containment Pressure Channel Declared Inoperable Due to Faulty Connection in B Train Sodium Selection Panel Input Cabinet 1.Caused by Contact Film Build Up + (14:11:26, 3 January 2025)
- 05000368/LER-1979-102-03, /03L-0:on 791221,during Mode 1 Operation,Core C Protection Calculator Failed.Caused by Speed Input Failure. Since Failure Was in Conservative Direction,Unit Returned to Svc + (14:11:35, 3 January 2025)
- ML19262B994 + (14:11:37, 3 January 2025)
- 05000368/LER-1979-101-03, /03L-0:on 791217,during Mode 1 Operation,Refueling Water Tank Level Indicator 2LI-5636-1 Failed High.Caused by Freeze Protection Heat Tracing Not Operating Properly, Allowing Transmitter Sensing Line to Freeze + (14:11:40, 3 January 2025)
- 05000348/LER-1979-066, Forwards LER 79-066/03L-0 + (14:11:43, 3 January 2025)
- 05000368/LER-1979-102, Forwards LER 79-102/03L-0 & Updated LER 79-008/03X-1 + (14:11:45, 3 January 2025)
- 05000368/LER-1979-101, Forwards LER 79-101/03L-0 + (14:11:48, 3 January 2025)
- ML19262B986 + (14:11:49, 3 January 2025)
- ML19262B985 + (14:11:51, 3 January 2025)
- ML19262B984 + (14:11:53, 3 January 2025)
- ML19262B983 + (14:11:54, 3 January 2025)
- ML19262B982 + (14:11:54, 3 January 2025)
- 05000302/LER-1979-109-03, /03L-0:on 791221,following Reactor Trip,Chem/Rod Sampling Showed Reactor Coolant Dose Equivalent I-131 Exceeded 1.0 Uci Per G Contrary to Tech Specs.Caused by Leaking Fuel Pins & Iodine Transient + (14:11:57, 3 January 2025)