Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19274D413 + (09:56:17, 3 January 2025)
- ML19274D411 + (09:56:18, 3 January 2025)
- ML19274D412 + (09:56:18, 3 January 2025)
- ML19274D408 + (09:56:19, 3 January 2025)
- ML19274D407 + (09:56:20, 3 January 2025)
- ML19274D406 + (09:56:21, 3 January 2025)
- 05000324/LER-1978-079, Forwards LER 78-079/03L-0 + (09:56:26, 3 January 2025)
- ML19274D402 + (09:56:27, 3 January 2025)
- 05000295/LER-1978-137-03, /03L-0 on 781211:operators Noticed 1FI543 Failed Low.Caused by Broken Fuseholder in Power Supply Hagen Model 4111085-001.Fuseholder Replaced & Channel Returned to Svc + (09:56:28, 3 January 2025)
- ML19274D399 + (09:56:29, 3 January 2025)
- ML19274D398 + (09:56:30, 3 January 2025)
- 05000295/LER-1978-137, Forwards LER 78-137/03L-0 + (09:56:31, 3 January 2025)
- ML19274D395 + (09:56:32, 3 January 2025)
- 05000295/LER-1978-136-03, /03L-0 on 781211:during Testing of Aircraft Fire Detection,Sys Failed to Trip Fan & Close Diesel Room Intake Damper.Caused by Blown Fuses in Control Box & Frozen Pneumatic Control Valve.Fuses Replaced + (09:56:34, 3 January 2025)
- 05000295/LER-1978-136, Forwards LER 78-136/03L-0 + (09:56:36, 3 January 2025)
- ML19274D386 + (09:56:38, 3 January 2025)
- ML19274D384 + (09:56:38, 3 January 2025)
- TAC:07713 + (09:56:39, 3 January 2025)
- ML19274D383 + (09:56:41, 3 January 2025)
- ML19274D381 + (09:56:41, 3 January 2025)
- ML19274D380 + (09:56:42, 3 January 2025)
- ML19274D379 + (09:56:43, 3 January 2025)
- ML19274D377 + (09:56:44, 3 January 2025)
- 05000324/LER-1978-064-03, /03L-1 on 780820:during Testing 3 Hydraulic Snubbers Found Inoperable.Snubber E11-95SS20 Was Low on fluid,G41-22SS85 Was Mechanically Disconnected & E11-37SS95 Had Cracked Support.Each Was Repaired or Replaced + (09:56:45, 3 January 2025)
- 05000267/LER-1978-039-03, /03L-0 on 781224:degraded Mode Operations Occurred During 2 Separate Repairs to a Buffer Helium Dryer Purge Valve.Caused by Leakage Past Valve Seat Which Required Bypass of Dryer + (09:56:47, 3 January 2025)
- 05000324/LER-1978-064, Forwards LER 78-064/03L-1 + (09:56:49, 3 January 2025)
- ML19274D371 + (09:56:50, 3 January 2025)
- ML19274D370 + (09:56:51, 3 January 2025)
- 05000333/LER-1978-109-03, /03L-0 on 781224:the a Residual Heat Removal Loop Could Not Be Maintained Full of Water Because a Discharge Check Valve Was Not Closing Properly.Disassembly Revealed No Cause for Sticking + (09:56:52, 3 January 2025)
- ML19274D367 + (09:56:53, 3 January 2025)
- 05000312/LER-1978-017-03, /03L-0:on 781215,during Refueling Shutdown, Blowdown Heat Transfer Pump Started & Sys Subjected to Sizable Water Hammer.Caused by Incomplete Valve Lineup. Hangers & Failed Snubber Repaired, & Personnel Notified + (09:56:55, 3 January 2025)
- ML19274D364 + (09:56:56, 3 January 2025)
- 05000312/LER-1978-017, Forwards LER 78-017/03L-0 + (09:56:58, 3 January 2025)
- 05000333/LER-1978-109, Forwards LER 78-109/03L-0 + (09:57:00, 3 January 2025)
- ML19274D359 + (09:57:04, 3 January 2025)
- ML19274D356 + (09:57:05, 3 January 2025)
- ML19274D358 + (09:57:05, 3 January 2025)
- ML19274D355 + (09:57:06, 3 January 2025)
- ML19274D354 + (09:57:07, 3 January 2025)
- ML19274D353 + (09:57:08, 3 January 2025)
- 05000245/LER-1978-031-03, /03L-0 on 781218:during Nuclear Review Board Audit a Surveillance Requirement (Reduced High Flux Prior to Startup) Was Found Unaccomplished Since Its Introduction. Caused by Procedural Error + (09:57:10, 3 January 2025)
- 05000245/LER-1978-031, Forwards LER 78-031/03L-0 + (09:57:12, 3 January 2025)
- ML19274D349 + (09:57:13, 3 January 2025)
- ML19274D348 + (09:57:14, 3 January 2025)
- 05000304/LER-1978-022-03, LER-022/03X-1 on 780222:grab Samples Not Obtained from 4 Tech Spec Rad Monitors Which Were Inoperable.Caused by Personnel Error + (09:57:16, 3 January 2025)
- 05000304/LER-1978-022, Forwards LER 78-022/03X-1 Update + (09:57:18, 3 January 2025)
- ML19274D343 + (09:57:19, 3 January 2025)
- SBK-L-19110, Supplement to License Amendment Request 18-02. Application to Revise the Technical Specifications Associated with Movable Control Rods + (09:57:20, 3 January 2025)
- ML19274D339 + (09:57:21, 3 January 2025)
- A15094, Effect of an Aluminum Alloy on Sanicro 31 at Elevated Temps. Final Rept on Metallurgical Examination Re Potential of Aluminum Alloy Chip.Steam Generator Leak Cracking from Liquid Metal Embrittlement Unlikely + (09:57:22, 3 January 2025)
- 05000237/LER-1978-067-03, /03L-0 on 781217:while Attempting to Put Drywall Continuous Air Monitor in Svc,Discovered Inboard Isolation Valve A.O.2-9207A Would Not Close.Caused by Dirty Parts & Water in Valve + (09:57:26, 3 January 2025)