- B10717, Advises of Minor Oversight in Documentation of Containment Water Level Monitoring Sys in Response to NUREG-0737,Item II.F.1.5.Design Verification Reveals wide-range Containment Water Level Monitor Measures Vol of 565,000 Gallons + (14:43:24, 26 May 2025)
- EPID:L-2019-LLA-0058 + (14:44:08, 26 May 2025)
- ML20071E019 + (14:44:16, 26 May 2025)
- 05000259/LER-1983-007-03, /03L-0:on 830205,MSRV 1-1-22 Failed to Close & Drywell Unidentified Leakage Exceeded 5 Gpm.Caused by Damaged Vacuum Relief Valve Failing to Reseat.Valve Replaced.Mod Planned During Next Refueling Outage + (14:44:28, 26 May 2025)
- 05000321/LER-1981-094-03, While Testing Standby Gas Treatment Filter Train A,Train Would Not Remove Greater than or Equal to 99% of Halogenated Hydrocarbon Gas,Per Tech Specs.Caused by Defective Charcoal + (14:44:42, 26 May 2025)
- 05000321/LER-1981-094, Forwards Updated LER 81-094/03X-1 + (14:44:47, 26 May 2025)
- 05000272/LER-1982-081, Supplemental LER 82-081/01X-1:on 821104,16 1,000-kip Steam Generator Snubbers Found Out of Spec on Bleed Test & Six Snubbers Failed Acceleration Test.Caused by Flattened Piston Seal Rubber Matl Due to Aging.Seals Rebuilt + (14:44:49, 26 May 2025)
- TAC:49793 + (14:44:51, 26 May 2025)
- ML20071D551 + (14:45:31, 26 May 2025)
- 05000260/LER-1983-004-01, /01T-0:on 830220,reactor Water Level Switch Setpoints Discovered out-of-tolerance.Caused by Setpoint Drift in Barton 288 Switches.Switches Recalibr & Will Be Replaced Per DCR 1398 + (14:45:32, 26 May 2025)
- ML20071D375 + (14:45:59, 26 May 2025)
- ML20071D351 + (14:46:05, 26 May 2025)
- PM-81-714, Forwards Semiannual Rept for Plant Radioactive Effluent Releases,Jan-June 1981 + (14:46:10, 26 May 2025)
- PM-81-713, Forwards Semiannual Rept for Plant Radioactive Effluent Releases,Jan-June 1981 + (14:46:11, 26 May 2025)
- TAC:49449 + (14:46:28, 26 May 2025)
- TAC:67442 + (14:46:35, 26 May 2025)
- PM-82-142, Forwards Semiannual Rept:Plant Radioactive Effluent Releases,Jul-Dec 1981 + (14:46:38, 26 May 2025)
- 05000311/LER-1983-003-03, /03L-0:on 830111,rod Position Indicator Channel 1SA2 Indicated Approx Half Scale,Contrary to Flux Map Indication That No Change in Rod Position Occurred.Caused by Failed Signal Conditioner.Module Replaced + (14:46:53, 26 May 2025)
- 05000254/LER-1983-006-03, /03L-0:on 830213,during Monthly Surveillance Test on Condenser Pit 5-ft Trip Circuits,Level Switch 1-4441-25B Failed to Give Circulating Water Pump Trip Signal.Caused by Broken Wire in Switch Mechanism.Switch Replaced + (14:46:56, 26 May 2025)
- 05000321/LER-1981-136-03, Both off-gas Hydrogen Analyzers Found Inoperable.Caused by Component Failure. Analyzer a Found Out of Calibr.Analyzer a Recalibr & Returned to Svc.Pumps Replaced on Analyzer B + (14:47:02, 26 May 2025)
- 05000321/LER-1981-136, Forwards Updated LER 81-136/03X-1 + (14:47:04, 26 May 2025)
- 05000315/LER-1983-002-03, /03L-0:on 830125,ice Condenser Intermediate Deck Door Weighing Procedure Revealed 70 Doors Exceeded Max Initial Opening Force Specs.Caused by Misalignment &/Or Dented Hinges.Hinges Realigned & Lubricated + (14:47:19, 26 May 2025)
- 05000315/LER-1983-002, Forwards LER 83-002/03L-0 + (14:47:23, 26 May 2025)
- ML20071C177 + (14:48:37, 26 May 2025)
- 05000324/LER-1983-010-03, /03L-0:on 830119,during Plant Operation,Both Doors of Reactor Bldg 20-ft Elevation Personnel Air Lock Opened Simultaneously.Caused by Misalignment of Inner Door Due to Normal Wear Preventing Proper Bolt Engagement + (14:49:09, 26 May 2025)
- 05000318/LER-1983-006-03, /03L-0:on 830123,auxiliary Feedwater Actuating Sys Channel Zd for Steam Generator 21 Level Indicated Low.Caused by Failure of Level Transmitter 2-LT-1114A Due to Defective Zero Adjustment Potentiometer.Transmitter Replaced + (14:49:11, 26 May 2025)
- 05000315/LER-1983-001-03, /03L-0:on 830118,Unit 2 Auxiliary Cable Vault Experienced Inadvertent Carbon Dioxide Discharge,Resulting in Isolation of Unit 1 & 2 Carbon Dioxide Tanks.Valve Closed & Main Isolation Reopened + (14:50:36, 26 May 2025)
- 05000315/LER-1983-001, Forwards LER 83-001/03L-0 (Previously Submitted as Unit 2 LER 83-022/03L-0) + (14:50:42, 26 May 2025)
- 05000321/LER-1981-129-01, Torus to Reactor Bldg Vacuum Relief Isolation Valve Failed to Close.Caused by Water Accumulation in Reactor Bldg Pressure Sensing Lines, Due to Improper Installation.Design Change Implemented + (14:51:01, 26 May 2025)
- 05000416/LER-1983-031, Forwards LER 83-031/99X-0 + (14:51:10, 26 May 2025)
- ML20071B222 + (14:51:54, 26 May 2025)
- ML20071B052 + (14:52:11, 26 May 2025)
- 05000373/LER-1982-090-03, During Startup Test Procedure 17,mechanical Snubber Found Damaged.Caused by Application of Excessive Forces in Lateral Direction Causing Snubber to Bend or Twist.Snubber Replaced + (14:52:16, 26 May 2025)
- 05000373/LER-1982-090, Forwards Revised LER 82-090/03X-1 + (14:52:22, 26 May 2025)
- TXX-9403, Forwards Addl Info Re License Amend Request 93-003 Re Control Room HVAC Sys,Including Control Room Air Conditioning Sys,Per Discussions W/Nrc + (14:52:27, 26 May 2025)
- ML20071A953 + (14:52:30, 26 May 2025)
- 05000318/LER-1983-004, Forwards LER 83-004/03L-0 + (14:52:58, 26 May 2025)
- ML20070W260 + (14:54:01, 26 May 2025)
- TAC:48501 + (14:54:07, 26 May 2025)
- ML20070V984 + (14:54:35, 26 May 2025)
- ML20070V631 + (14:54:52, 26 May 2025)
- 05000416/LER-1982-059-01, While Performing RHR High to Low Pressure Interface Valve Leakage Test,Setpoints for RHR Injection Valve Differential Pressure Switches Found Greater than Tech Specs.Caused by Misinterpretation + (14:55:02, 26 May 2025)
- 05000416/LER-1982-059, Forwards Updated LER 82-059/01X-1 + (14:55:05, 26 May 2025)
- 05000260/LER-1982-035-03, During Refueling Outage, While Performing Surveillance Insp 4.6.H-2,upper Mechanical Snubber on Main Steam Line D Found Inoperable.Snubber Replaced.Engineering Analysis Encl + (14:55:45, 26 May 2025)
- 05000366/LER-1980-073-03, Hydrogen Combiner B Failed to Start During Test.Caused by Temp Controller Setpoint Too Close to Sys Trip Setpoint.Procedure Revised to Lower Controller Setpoint + (14:55:57, 26 May 2025)
- 05000366/LER-1980-073, Forwards Updated LER 80-073/03X-1 + (14:56:00, 26 May 2025)
- 05000281/LER-1981-052-03, Valve MOV-SW-202A Failed to Close Due to Grounded Motor.Grounding Caused by Flooding in Sump.Motor Replaced + (14:56:09, 26 May 2025)
- 05000321/LER-1979-076-01, Plant Engineering Personnel Confirmed NSSS Vendor Info Re Cable Separation Irregularities in HPCI Sys.Caused by Design Error.Cable Will Be Rerouted Per Design Change Request 79-379 + (14:56:18, 26 May 2025)
- 05000321/LER-1979-076, Forwards Updated LER 79-076/01X-1 + (14:56:21, 26 May 2025)
- 05000366/LER-1980-130-03, Primary Containment Hydrogen & Oxygen Analyzer Found Inoperable.Caused by Analyzer Being Out of Calibr.Analyzer Calibr + (14:56:28, 26 May 2025)
- 05000366/LER-1980-130, Forwards Updated LER 80-130/03X-1 + (14:56:31, 26 May 2025)