Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000333/LER-1992-032, :on 920605,determined That Portion of Primary Containment Isolation Logic Had Not Been Tested Due to Procedural Deficiency.Surveillance Test Procedure Will Be Corrected + (01:10:39, 26 May 2025)
- ML20101Q096 + (01:10:41, 26 May 2025)
- ML20101Q094 + (01:10:46, 26 May 2025)
- ML20101Q090 + (01:10:47, 26 May 2025)
- ML20101Q056 + (01:10:52, 26 May 2025)
- ML20101Q046 + (01:10:54, 26 May 2025)
- ML20101Q037 + (01:10:56, 26 May 2025)
- L-82-033, Forwards NUREG-0737,Suppl 1 Compliance Submittal,Including Proprietary SAR for Spds,Brunswick Steam Electric Plant Emergency Response Facilities Info Sys, Per Generic Ltr 82-33 & 840222 Order.Sar Withheld (Ref 10CFR2.790) + (01:10:59, 26 May 2025)
- 05000416/LER-1992-011, :on 920608,discovered Possibility of Potential Secondary Containment Bypass Leakage Paths & Control Room Boundary Leakage Paths.On 911009,temporary Shaft Seal Installed in Sgts.Also Reported Per Part 21 + (01:11:11, 26 May 2025)
- ML20101P747 + (01:11:24, 26 May 2025)
- ML20101M792 + (01:13:32, 26 May 2025)
- 05000302/LER-1995-023, :on 951027,engineering Personnel Determined Bldg Spray Flow Valves Used in Various Engineering Calculations Inconsistent.Caused by Design Analysis Deficiency.Problem Rept Issued + (01:13:34, 26 May 2025)
- 05000374/LER-1984-079-01, :on 841121,reactor Water Cleanup Sys Isolated on High Differential Flow.Caused by Addl Sys Perturbation. Sys Restarted + (01:13:36, 26 May 2025)
- ML20101M771 + (01:13:38, 26 May 2025)
- 05000397/LER-1984-123, :on 841202,normal Div I Critical Switchgear Room Cooling Lost Due to Manual Shutdown Caused by Vibration of Fan Unit.All Div I Equipment Declared Inoperable.Fan Shaft Replaced & Bearings Installed + (01:13:44, 26 May 2025)
- 05000397/LER-1984-122, :on 841002,fire Door Supervisory Alarm Circuit on Door to Diesel Generator Terminated Due to Drawing Error. Door Discovered Inoperable on 841026.Hourly Fire Watch Posted + (01:13:46, 26 May 2025)
- 05000397/LER-1984-121, :on 841026,samples from Three Diesel Fuel Oil Storage Tanks Delivered to Warehouse for Shipment.Acceptable Results Not Received Until 841128 Because Samples Not Shipped Rush.Procedure Modified + (01:13:49, 26 May 2025)
- 05000416/LER-1984-054, :on 841129,time Limit for Tech Specs 4.11.2.2 & 4.11.2.3 Exceeded When Effluent Cumulative Dose Calculations & Surveillance Not Performed.Caused by Personnel Error. Surveillance Completed on 841130 + (01:13:50, 26 May 2025)
- 05000296/LER-1984-001, :on 840103,emergency Diesel Generator Overheated.Caused by Clam Shells Blocking Emergency Equipment Cooling Water Sys Inlet Tube Sheet.Flushing of Main Header Established + (01:13:52, 26 May 2025)
- 05000454/LER-1984-017-07, :on 841123,train a Safety Injection (SI) Actuated.Caused by Operator Placing Main Control Board Safety Injection Switch in Incorrect Position.Addl Training Re Protection Sys Initiated + (01:13:54, 26 May 2025)
- TAC:54596 + (01:13:59, 26 May 2025)
- 05000325/LER-1984-033, :on 841119,discovered Common Chlorine Detection Sys Failed to Meet Fsar/Tech Spec Design Criteria.Caused by Inadequate Chlorine Detection Sys Signal.Plant Mod to Meet Design Criteria Implemented + (01:14:02, 26 May 2025)
- ML20101M576 + (01:14:04, 26 May 2025)
- 05000416/LER-1984-052, :on 841124,scram Occurred on Low Reactor Water Level.Caused by Opening of Feedwater Isolation Valve Per Cleanup Procedure.Level Restored by Resetting Reactor Feed Pump Turbine a + (01:14:05, 26 May 2025)
- 05000327/LER-1984-072, :on 841207,functional Discrepancy for post- Accident Radiation Monitors for Reactor Coolant Drain Tank Discharge Piping Identified.Caused by Incorrect Drawings. Monitors Revised + (01:14:09, 26 May 2025)
- 05000454/LER-1984-014-06, :on 841121,12 H Grab Samples from Process Monitors Not Obtained Per Tech Specs.Caused by Personnel Error.Tighter Administrative Controls Implemented + (01:14:13, 26 May 2025)
- ML20101M547 + (01:14:15, 26 May 2025)
- 05000454/LER-1984-015-07, :on 841125,auxiliary Bldg Vent Stack Monitor Inoperable & Gas Grab Sample Missed.Caused by Personnel Error.Control Room Personnel & rad-chem Foremen Required to Verify Action Prior to Sampling Termination + (01:14:18, 26 May 2025)
- 05000328/LER-1992-003, :on 920327,snubber Observed Disconnected from Pipe Clamp & Various Support Attachment Bolts Found Loose or Missing.Caused by Temporary Worker Failing to Follow Procedure.Work Request Initiated + (01:14:28, 26 May 2025)
- 05000336/LER-1992-010-02, :on 920530,discovered That Main Steam Safety Valve Setpoint Drifted.Cause Unknown.Setpoint Adjustments Made & Passed Retest + (01:14:30, 26 May 2025)
- ML20101M464 + (01:14:32, 26 May 2025)
- ML20101M449 + (01:14:33, 26 May 2025)
- ML20101M447 + (01:14:35, 26 May 2025)
- 05000373/LER-1984-082, :on 841124,reactor Water Cleanup Sys Isolated on High Differential Flow.Caused by Reactor Startup Due to Water Temp,Pressure & Density Differences Between Startup Operations & Instrument Calibr + (01:14:39, 26 May 2025)
- ST-HL-AE-1165, Forwards 110 Oversize Electrical & Instrumentation & Control Drawings,Per Section 1.7 of Reg Guide 1.70 & NRC Question 032.01.Aperture Cards Available in PDR + (01:14:51, 26 May 2025)
- ML20101M270 + (01:14:53, 26 May 2025)
- ML20101M195 + (01:15:02, 26 May 2025)
- ML20101M190 + (01:15:04, 26 May 2025)
- 05000296/LER-1984-012-03, :on 841120,reactor Scrammed by Reactor Operator When Control Room Indication Showed Low Water Level Scram Setpoint Exceeded.Caused by Procedural Inadequacy.Procedures Revised + (01:15:05, 26 May 2025)
- 05000370/LER-1984-028-01, :on 841113,upper Head Injection Hydraulic Sys Alarm for Train B Received in Control Room.Caused by Component Malfunction.Calibr Procedure Revised + (01:15:09, 26 May 2025)
- 05000321/LER-1984-014, :on 841011,cracking Found in RCS Pressure Boundary.Caused by IGSCC in 21 of 22 Welds.Five Welds Found Acceptable.Remaining 17 Welds Will Be Repaired Via Weld Overlay + (01:15:11, 26 May 2025)
- ML20101M092 + (01:15:12, 26 May 2025)
- 05000327/LER-1984-071, :on 841121,radiation Monitors for Containment Ventilation Isolation Not Adequately Verified.Caused by Misinterpretation of Surveillance Requirement.Surveillance Instruction 6 Will Be Revised + (01:15:16, 26 May 2025)
- 05000373/LER-1984-081, :on 841123,HPCS Pump Suction Valve to Suppression Pool Opened While Normal Suction Valve to Cycled Condensate Tank Closed.Caused by High Suppression Pool Level.Pool Level Lowered + (01:15:29, 26 May 2025)
- 05000374/LER-1984-076-01, :on 841120,turbine Bypass Sys Declared Inoperable When Solenoid on Bypass Valves Showed Infinite Resistance.Caused by Malfunctioning Solenoid.Solenoid Valve Assembly Replaced + (01:15:32, 26 May 2025)
- 05000424/LER-1996-002-01, :on 960313,discovered That ECCS Valves Cycled on Five Occasions from 960222-29 Leading to Unit Operation in Condition Prohibited by Ts.Caused by Cognitive Personnel Error.Involved Personnel Counseled + (01:15:39, 26 May 2025)
- 05000454/LER-1995-008-01, :on 951109,inadequate Test for Compliance with Llrt.Caused by a Procedure That Did Not Adequately Identify That Plugs Were Removed.C/A:Procedure Revision Initiated and Maint Foreman Counseled + (01:15:42, 26 May 2025)
- 05000395/LER-1992-004, :on 920521,reactor Tripped from 9% Power on low-low SG Water Level in C Sg.Caused by Condenser Steam Dump Valves Not Fully Opening on Demand.Transducers Were Replaced W/Lower Impedance Transducers + (01:16:02, 26 May 2025)
- 05000254/LER-1992-011-03, :on 920530,Unit 1 in Shutdown Mode Performing Cooldown to Cold Condition for Maint Outage.Caused by Procedural Inadequacy.Cooldown Rate Minimized & Thermocouple Replaced + (01:16:05, 26 May 2025)
- ML20101L697 + (01:16:10, 26 May 2025)
- ML20101L686 + (01:16:13, 26 May 2025)