- 05000301/LER-1980-008-01, /01T-0:on 800912,following Trip from Full Power, Main Steam Stop Valve B Failed to Close Upon Receiving Close Signal.Caused by Deposit Buildup on Valve Shaft &/Or Hardening of Gland Packing + (18:48:15, 25 December 2024)
- 05000313/LER-1980-033-03, /03L-0:on 800906,during Normal Cooldown Operations,Rcs Makeup Block Valve Failed to Close Fully on Command.Caused by High Differential Across Valve,Resulting in Operation of Close Torque Limit Switch + (18:48:25, 25 December 2024)
- 05000325/LER-1980-068-03, /03L-0:on 800901,during rod-block Monitor Blocks, a rod-block Monitor Trip Actuated at Less than Required Setpoint.Caused by Instrument Drift.Monitors Recalbr + (18:48:40, 25 December 2024)
- 05000368/LER-1980-058, Forwards Updated LER 80-058/03X-1 + (18:48:47, 25 December 2024)
- ML19338F142 + (18:48:55, 25 December 2024)
- 05000301/LER-1980-008, Forwards LER 80-008/01T-0 + (18:48:58, 25 December 2024)
- 05000313/LER-1980-033, Forwards LER 80-033/03L-0 + (18:49:03, 25 December 2024)
- 05000324/LER-1980-052-03, /03L-0:on 800903,during Reactor Startup Following Refueling Outage,Several Control Rods Were Found to Have Position Indication Problems.Caused by Defective Transistors in Probe Buffer Cards.Transistors Replaced + (18:49:18, 25 December 2024)
- 05000325/LER-1980-068, Forwards LER 80-068/03L-0 + (18:49:22, 25 December 2024)
- B10074, Application to Amend Ol.Forwards Revision to App B of ETS to Delete Section 4.2 Re Shad Monitoring Program.Also Forwards Population Dynamics of American Shad (Alosa Sapidissima) in CT River,1940-1977 + (18:49:25, 25 December 2024)
- ML19338F131 + (18:49:28, 25 December 2024)
- ML19338F130 + (18:49:31, 25 December 2024)
- ML19338F129 + (18:49:33, 25 December 2024)
- 05000313/LER-1980-032-04, /04L-0:on 800905,during Cooldown Following Steam Generator Tube Leak,Excessive Release of Radioactive Matls in Gaseous Wastes Occurred.Caused by Premature Lifting of Letdown Relief Valve PSV-1236.Valve Was Readjusted + (18:49:39, 25 December 2024)
- ML19338F124 + (18:49:45, 25 December 2024)
- 05000324/LER-1980-052, Forwards LER 80-052/03L-0 + (18:49:52, 25 December 2024)
- ML19338F121 + (18:49:54, 25 December 2024)
- ML19338F119 + (18:50:01, 25 December 2024)
- ML19338F118 + (18:50:02, 25 December 2024)
- 05000313/LER-1980-032, Forwards LER 80-032/04L-0 + (18:50:05, 25 December 2024)
- ML19338F115 + (18:50:07, 25 December 2024)
- 05000339/LER-1980-060-03, /03L-0:on 800913,in Mode 1,procedure 2-PT-62.4 Revealed That Leakage Past Outer Seals on Personnel Air Lock Door Exceeded Tech Specs.Caused by Misaligned Personnel Hatch on Outer Door + (18:50:10, 25 December 2024)
- 05000368/LER-1979-056, Forwards Updated LER 79-056/03X-1 + (18:51:19, 25 December 2024)
- ML19338F110 + (18:51:23, 25 December 2024)
- ML19338F109 + (18:51:25, 25 December 2024)
- 05000334/LER-1980-070-01, /01T-0:on 800922,unplanned Dilution of RCS Occurred.Caused by Boric Acid Blender Procedure Not Accounting for Manual Emergency Boration Flow Path Being in Svc.Procedure Has Been Changed + (18:51:28, 25 December 2024)
- 05000293/LER-1980-062-03, /03L-0:on 800903,following Surveillance Testing, a Diesel Generator Declared Inoperable Due to Snapped Fuel Line in Area of Diesel Generator Cylinder 9R.Caused by Severed Fuel Crossover T Type Connector + (18:51:40, 25 December 2024)
- 05000339/LER-1980-063-03, /03L-0:on 800920,during Performance of incore- Excore Detector Calibr Startup Test,Found Zero Point Shift of Delta T/T Avg Channel III Summing Amp.Cause Undetermined. Channel Placed in Trip & New Summing Amp Installed + (18:52:18, 25 December 2024)
- ML19338F104 + (18:52:21, 25 December 2024)
- 05000339/LER-1980-060, Forwards LER 80-060/03L-0 + (18:53:00, 25 December 2024)
- 05000334/LER-1980-070, Forwards LER 80-070/01T-0 + (18:53:40, 25 December 2024)
- 05000293/LER-1980-062, Forwards LER 80-062/03L-0 + (18:54:57, 25 December 2024)
- ML19338F094 + (18:55:00, 25 December 2024)
- 05000339/LER-1980-063, Forwards LER 80-063/03L-0 + (18:55:21, 25 December 2024)
- 05000339/LER-1980-061-03, /03L-0:on 800919,LHSI Pump B Relieve Valve Actuated at 190 Psia Rather than 220 Psia.Probably Caused by Weakened Spring Action Allowing Lower Pressure to Open Valve.Spring Tension Reset & Valve Returned to Svc + (18:55:51, 25 December 2024)
- 05000339/LER-1980-050-03, /03L-0:on 800902,during Mode 5,pressurizer power- Operated Relief Valve Was Inoperable When Nitrogen Supply Dropped.Caused by Low Nitrogen Pressure.Pressure Was Restored in 12-h by Renewing Supply & Pressurizing Tanks + (18:56:20, 25 December 2024)
- 05000285/LER-1980-022-03, /03L-0:on 800911,during Safety Injection Actuation Signal Surveillance test,86B/VIAS Lockout Failed to Trip. Caused by Burned Coil.Coil Replaced W/Spare & Tested Satisfactorily for Proper Operation + (18:56:44, 25 December 2024)
- ML19338F087 + (18:56:46, 25 December 2024)
- 05000254/LER-1980-022-03, /03L-0:on 800903,during Calibr Surveillance,Temp Switch TS 1-2371A Tripped at 212 F Rather than 200 F.Caused by Setpoint Drift.Switch Replaced + (18:57:04, 25 December 2024)
- ML19338F085 + (18:57:08, 25 December 2024)
- 05000346/LER-1980-069-03, /03L-0:on 800902,during Diesel Generator 1-1 Oil Change,Bolt Fragment Discovered in Crankcase Sump.Caused by Loose Bolts in Idler Gear to Support Spider of Turbocharger Spring Drive Assembly.Modified Assembly Installed + (18:58:26, 25 December 2024)
- 05000285/LER-1980-022, Forwards LER 80-022/03L-0 + (18:58:47, 25 December 2024)
- 05000339/LER-1980-061, Forwards LER 80-061/03L-0 + (18:58:57, 25 December 2024)
- 05000254/LER-1980-022, Forwards LER 80-022/03L-0 + (18:59:09, 25 December 2024)
- 05000339/LER-1980-050, Forwards LER 80-050/03L-0 + (18:59:27, 25 December 2024)
- ML19338F074 + (18:59:30, 25 December 2024)
- ML19338F072 + (18:59:33, 25 December 2024)
- 05000278/LER-1980-023-03, /03L-0:on 800908,reactor Water Cleanup Demineralizer Water Inlet Temp Switch Did Not Actuate at 200 F.Caused by Setpoint Drift.Switch Recalibr & Satisfactorily Tested + (18:59:52, 25 December 2024)
- ML19338F069 + (18:59:58, 25 December 2024)
- ML19338F067 + (18:59:59, 25 December 2024)
- 05000346/LER-1980-069, Forwards LER 80-069/03L-0 + (19:00:28, 25 December 2024)