- ML20004D663 + (16:03:00, 23 December 2024)
- 05000259/LER-1981-025, Forwards LER 81-025/01T-0 + (16:03:01, 23 December 2024)
- ML20004D659 + (16:03:04, 23 December 2024)
- 05000267/LER-1981-033, Forwards LER 81-033/03L-0.Detailed Event Analysis Encl + (16:03:10, 23 December 2024)
- 05000259/LER-1981-023-03, /03L-0:on 810510,damaged Cable Heat Tray Detector Caused False Alarm Which Could Have Masked Other Alarms. Probable Cause of Damaged Heat Detector Attributed to Cable Pulling Crew.Heat Detector Replaced & Functionally Tested + (16:03:12, 23 December 2024)
- ML20004D650 + (16:03:13, 23 December 2024)
- 05000259/LER-1981-023, Forwards LER 81-023/03L-0 + (16:03:15, 23 December 2024)
- ML20004D644 + (16:03:16, 23 December 2024)
- ML20004D643 + (16:03:20, 23 December 2024)
- TXX-3138, Final Deficiency Rept Re Violation of Piping Min Wall Thickness,Initially Reported on 790522.Revisions to Fabrication & Documents Completed.Final Stress Analyses Are Targeted for Completion Prior to Hot Functional Testing + (16:03:21, 23 December 2024)
- ML20004D640 + (16:03:24, 23 December 2024)
- 05000318/LER-1981-009-03, /03L-0:on 810330,during Normal Power Operation, Motor Operated Isolation Valve in Saltwater Sys Would Not Operate Electrically.Caused by Tripped Overload Devices on Phase a & C.Devices Reset + (16:03:25, 23 December 2024)
- 05000339/LER-1981-041-03, /03L-0:on 810512,reservoir of Snubber 2-RC-HSS-463-1 Found Empty of Fluid.Caused by Hairline Crack in Lexan Reservoir Tube.Snubber Replaced W/Spare + (16:03:27, 23 December 2024)
- 05000296/LER-1981-019-03, During Shutdown,When HPCI Sys Initiated,Upper & Lower HPCI Gland Seal Condenser Head Gaskets Were Blown.Caused by Overpressurization of Tube Side of HPCI Gland Seal Condenser.Gaskets Replaced + (16:03:29, 23 December 2024)
- ML20004D631 + (16:04:10, 23 December 2024)
- 05000318/LER-1981-009, Forwards LER 81-009/03L-0 + (16:04:11, 23 December 2024)
- 05000339/LER-1981-041, Forwards LER 81-041/03L-0 + (16:04:13, 23 December 2024)
- PNO-IV-81-014, on 810602,four Individuals Investigating Source of Unidentified Primary Sys Leakage in Containment Bldg Received Possible Overexposure of Neutrons.Exposure May Be Incorrect.Neutron TLD Calibr Is Under Investigation + (16:04:18, 23 December 2024)
- 05000317/LER-1981-003-03, /03L-0:on 810217,engineered Safety Features Actuation Sys Channel 2D 12 Steam Generator Pressure Isolator Found Out of Spec.Caused by Transmation Isolator w/non-liner Output.Isolator Replaced + (16:04:19, 23 December 2024)
- ML20004D621 + (16:04:21, 23 December 2024)
- ML20004D620 + (16:04:22, 23 December 2024)
- 05000339/LER-1981-040-03, /03L-0:on 810508,axial Flux Difference Deviated Greater than 5% from Target for 28 Penalty Minutes During Rampdown from Full Power for Scheduled Outage.Caused by Control Rods Being High in Core.Rods Inserted + (16:04:24, 23 December 2024)
- 05000317/LER-1981-003, Forwards LER 81-003/03L-0 + (16:04:26, 23 December 2024)
- 05000346/LER-1981-028-03, /03L-0:on 810505,log Review Showed That Liquid Release Had Been Made While Radiation Monitors Re 1878A & B Were Inoperable Due to Testing Date Being Exceeded.Caused by Personnel Error.Personnel Will Be Counseled + (16:04:27, 23 December 2024)
- 05000339/LER-1981-040, Forwards LER 81-040/03L-0 + (16:04:32, 23 December 2024)
- 05000346/LER-1981-028, Forwards LER 81-028/03L-0 + (16:04:34, 23 December 2024)
- ML20004D604 + (16:04:40, 23 December 2024)
- 05000339/LER-1981-038-03, /03L-0:on 810505,during Mode 1 Operation,Channel III Feedwater Flow Indication for Loop 2 Failed High.Caused by Failure of Loop Multiplier/Divider/Square Root Card.Card Replaced & Channel Recalibr & Returned to Svc + (16:04:42, 23 December 2024)
- ML20004D601 + (16:04:43, 23 December 2024)
- 05000366/LER-1981-048-03, /03L-0:on 810527,while Operating at 99% Power Control Rod Scram Accumulator 26-47 Found Inoperative.Caused by Leakage in Instrument Block Valve III of Accumulator. Accumulator Recharged Per HNP-2-1425 Procedure + (16:04:44, 23 December 2024)
- ML20004D599 + (16:04:48, 23 December 2024)
- 05000318/LER-1981-004-03, /03L-0:on 810204, While Conducting Preventive Maint,Shutdown Cooling Flow Lost.Caused by Procedure Not Containing Sufficient Info.Flow Lost Due to de-energized Vital Ac Bus Causing Valve to Shut.Procedure Revised + (16:04:49, 23 December 2024)
- 05000339/LER-1981-038, Forwards LER 81-038/03L-0 + (16:04:51, 23 December 2024)
- 05000312/LER-1981-027-03, /03L-0:on 810502,RBS Pump Breaker 3A09 Tripped When Attempting Start from Control Room.Cause Unknown.Trip Reset + (16:04:56, 23 December 2024)
- ML20004D592 + (16:04:57, 23 December 2024)
- ML20004D591 + (16:04:58, 23 December 2024)
- 05000318/LER-1981-004, Forwards LER 81-004/03L-0 + (16:04:59, 23 December 2024)
- 05000312/LER-1981-027, Forwards LER 81-027/03L-0.Detailed Event Analysis Also Submitted + (16:05:02, 23 December 2024)
- ML20004D586 + (16:05:03, 23 December 2024)
- 05000366/LER-1981-048, Forwards LER 81-048/03L-0 + (16:05:05, 23 December 2024)
- ML20004D582 + (16:05:06, 23 December 2024)
- 05000327/LER-1981-055-03, /03L-0:on 810504,waste Gas Decay Tank E Was Found to Have Oxygen Concentration of 2.025% & Hydrogen Concentration of 14.47%.Apparently Caused by Oxygen Being Drawn from Unit 2 Tanks During Preop Testing + (16:05:08, 23 December 2024)
- ML20004D580 + (16:05:09, 23 December 2024)
- 05000298/LER-1980-047-03, /03L-0:on 801117,RHR Loop a Suppression Pool Cooling Inboard Throttle Valve Found Inoperable.Caused by Key Failure Between Motor Pinion Gear & Shaft Due to Wrong Key Matl Installed.Motor,Pinion Gear & Key Replaced + (16:05:10, 23 December 2024)
- 05000254/LER-1980-031-03, /03L-0:on 801124,pressure Switch PS-1-261-30D Tripped Low During Main Steam Line Low Pressure Calibr Test. Caused by Instrument Setpoint Drift.Pressure Switch Recalibr & Tested Satisfactorily + (16:05:15, 23 December 2024)
- ML20004D576 + (16:05:17, 23 December 2024)
- ML20004D575 + (16:05:18, 23 December 2024)
- ML20004D574 + (16:05:19, 23 December 2024)
- ML20004D573 + (16:05:20, 23 December 2024)
- ML20004D571 + (16:05:21, 23 December 2024)
- 05000327/LER-1981-055, Forwards LER 81-055/03L-0 + (16:05:23, 23 December 2024)