Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20009A535 + (06:48:41, 23 December 2024)
- 05000267/LER-1981-034-03, /03L-0:on 810504,equipment Necessary to Terminate Release from Liquid Waste Sys & Reactor Sump Found Not Operating Properly.Caused by Plugged Sense Lines on Flow Element Associated W/Control Valve + (06:48:44, 23 December 2024)
- 05000298/LER-1981-010, Forwards LER 81-010/03L-0 + (06:48:47, 23 December 2024)
- 05000334/LER-1981-055-03, /03L-0:on 810529,during Maint Surveillance Test, High Level Alarm on Safety Injection Accumulator 1C Was Discovered Above High Limit.Caused by Instrument Drift.Trip Voltage Adjusted + (06:48:50, 23 December 2024)
- 05000267/LER-1981-034, Forwards LER 81-034/03L-0.Detailed Event Analysis Encl + (06:48:53, 23 December 2024)
- 05000267/LER-1981-032-03, /03L-0:on 810428,hot Reheat Snubber HRS-244 Found Inoperable.Caused by Empty Hydraulic Oil Reservoir Due to Leaking Elbow Fitting.Fitting Tightened,Reservoir Refilled & Snubber Returned to Svc + (06:48:55, 23 December 2024)
- 05000334/LER-1981-054-03, /03L-0:on 810527,outside Recirculation Spray PP2A Seal Water Level Low Alarm Sounded Following Surveillance Testing.Caused by Seal Package Retaining Ring Sticking & Preventing Proper Alignment.Seal Replaced & Retainer Lubed + (06:48:58, 23 December 2024)
- PNO-I-81-075, on 810706,unit Shut Down When Middle Seal of Reactor Coolant Pump 11B Failed.Seal Replacement Expected in 7 Days + (06:49:01, 23 December 2024)
- 05000267/LER-1981-032, Forwards LER 81-032/03L-0.Detailed Event Analysis Encl + (06:49:03, 23 December 2024)
- ML20009A522 + (06:49:04, 23 December 2024)
- W3P81-1566, Forwards Revision 6 to Physical Security Plan.Plan Withheld (Ref 10CFR2.790) + (06:49:09, 23 December 2024)
- ML20009A519 + (06:49:09, 23 December 2024)
- ML20009A516 + (06:49:14, 23 December 2024)
- 0CAN078102, Informs That Further Repts & Evaluations Re EPRI PWR Safety & Relief Valve Test Program Will Be Submitted Per 801215 Schedule,As Modified on 810701 + (06:49:15, 23 December 2024)
- ML20009A512 + (06:49:22, 23 December 2024)
- A810021, Forwards Response to NUREG-0737 TMI Action Plan Requirements & Meteorological Monitoring Sys Development Plan for Emergency Preparedness, Preliminary Rept Prepared by Dames & Moore Per NUREG-0654 + (06:49:23, 23 December 2024)
- 05000311/LER-1981-032-03, /03L-0:on 810603,boron Injection Tank Concentration Decreased Below Tech Spec Limits.Caused by Safety Injection Initiated by High Streamline Flow from High Level in Steam Generator 22.Tank Borated + (06:49:27, 23 December 2024)
- 05000311/LER-1981-032, Forwards LER 81-032/03L-0.Detailed Event Analysis Encl + (06:49:31, 23 December 2024)
- ML20009A502 + (06:49:33, 23 December 2024)
- ML20009A501 + (06:49:34, 23 December 2024)
- ML20009A500 + (06:49:35, 23 December 2024)
- ML20009A499 + (06:49:36, 23 December 2024)
- ML20009A497 + (06:49:37, 23 December 2024)
- ML20009A496 + (06:49:38, 23 December 2024)
- 05000333/LER-1981-049-03, /03L-0:on 810704,following Surveillance During Normal Operation,One of 16 Main Steam High Flow Instruments Did Not Respond Properly.Caused by Rust Plugging Pressure Snubber Sensing Line.Snubber Cleaned & Tested + (06:49:40, 23 December 2024)
- 05000333/LER-1981-049, Forwards LER 81-049/03L-0 + (06:49:45, 23 December 2024)
- IR 05000498/1981020 + (06:49:49, 23 December 2024)
- ML20009A488 + (06:49:50, 23 December 2024)
- ML20009A487 + (06:49:52, 23 December 2024)
- ML20009A485 + (06:49:53, 23 December 2024)
- JAFP-81-0343, Responds to NRC Re Violation Noted in IE Insp Rept 50-333/81-02.Corrective Actions:Importance of Assigning Personnel to Tasks Only When Aware of Procedures Stressed to Supervisors + (06:49:56, 23 December 2024)
- JAFP-81-0618, Suppls 810409 Response to NRC Re Violation & Noted in IE Insp Rept 50-333/81-02.Corrective Actions:Memo Issued to Licensed Personnel Reiterating Importance of Applicable Plant Procedures + (06:49:59, 23 December 2024)
- ML20009A482 + (06:49:59, 23 December 2024)
- ML20009A480 + (06:50:05, 23 December 2024)
- ML20009A479 + (06:50:05, 23 December 2024)
- 05000311/LER-1981-034-03, /03L-0:on 810603,during Refill of Boron Injection Tank,Samples Indicated Concentration Less That 20,000 Ppm. Caused by Boron Tank Not Completely Drained Prior to Refill.Tanks Borated to Between 20,000 & 22,500 Ppm + (06:50:07, 23 December 2024)
- ML20009A476 + (06:50:09, 23 December 2024)
- 05000311/LER-1981-034, Forwards LER 81-034/03L-0.Detailed Event Analysis Encl + (06:50:11, 23 December 2024)
- JAFP-81-0661, Advises That Completion of Mods to Masonry Walls Is Not Possible by 810630,per IE Bulletin 80-11.Mod of Walls in Vicinity of Emergency Diesel Generators & Electrical Bays Could Not Be Performed Simultaneously + (06:50:12, 23 December 2024)
- ML20009A472 + (06:50:14, 23 December 2024)
- 05000311/LER-1981-030-03, /03L-0:on 810530,during Startup Operations, Auxiliary Feed Pump 21 Outboard Bearing Went Into High Temp Alarm & Was Removed from Svc.Caused by Failure of Outboard Bearing & Seal Assembly.Components Replaced + (06:50:16, 23 December 2024)
- 05000311/LER-1981-030, Forwards LER 81-030/03L-0.Detailed Event Analysis Encl + (06:50:18, 23 December 2024)
- 2CAN078103, Provides Correction Re 810330 Responses to Questions on Low Temp Overpressurization Mods + (06:50:19, 23 December 2024)
- ML20009A464 + (06:50:22, 23 December 2024)
- ML20009A463 + (06:50:23, 23 December 2024)
- ML20009A460 + (06:50:27, 23 December 2024)
- 05000293/LER-1981-026-01, /01X-0:on 810707,during Engineering Analyses, Components of Standby Gas Treatment Sys Were Found to Have Insufficient Documentation to Demonstrate Operation During Loca.Documentation Acquired + (06:50:29, 23 December 2024)
- ML20009A458 + (06:50:31, 23 December 2024)
- 05000336/LER-1981-021-03, /03L-0:on 810612,w/plant at 100% Power,A & B Charging Pumps Were Declared Inoperable.Caused by Incorrect Installation of Suction & Discharge Seal Cylinder Assembly Flushing Nipple Blank Flanges.Mods Made + (06:50:33, 23 December 2024)
- 05000336/LER-1981-021, Forwards LER 81-021/03L-0.Detailed Event Analysis Encl + (06:50:36, 23 December 2024)
- ML20009A453 + (06:50:38, 23 December 2024)