Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000287/LER-1981-011-03, /03L-0:on 810518,safety-related Mechanical Snubber Was Discovered Inoperable During Visual Insp.Caused by Ball Screw Shaft of Snubber Being Slightly Scored,Prohibiting Ball Bearings from Running Smoothly.Snubber Replaced + (06:18:49, 23 December 2024)
- 05000369/LER-1981-089, Forwards LER 81-089/03L-0.Detailed Event Analysis Encl + (06:18:52, 23 December 2024)
- 05000369/LER-1981-047-03, /81-03L-0:on 810408,while in Mode 4,containment Particulate Radiation Activity Monitor EMF-38 Was Declared Inoperable Due to False High Radiation Alarm.Caused by Low Level Setting of Alarm Setpoints.Setpoints Adjusted + (06:18:54, 23 December 2024)
- 05000287/LER-1981-011, Forwards LER 81-011/03L-0.Detailed Event Analysis Encl + (06:18:59, 23 December 2024)
- 05000369/LER-1981-060-03, /03L-0:on 810420,while in Mode 3,initial Fuel Loading,Channel 1 Cold Leg Injection Accumulator 1D Tank Level Indicator Fluctuated & Failed High.Caused by Faulty Transmitter.New Transmitter Installed & Calibr + (06:19:01, 23 December 2024)
- 05000287/LER-1981-009-03, /03L-0:on 810507,containment Isolation Valve 3CS-6 Was Discovered in Intermediate Position,Resulting in Loss of Containment Integrity.Cause Undetermined.Valve 3CS-6 Verified Operable + (06:19:03, 23 December 2024)
- 05000369/LER-1981-047, Forwards LER 81-047/03L-0.Detailed Event Analysis Encl + (06:19:05, 23 December 2024)
- 05000369/LER-1981-060, Forwards LER 81-060/03L-0.Detailed Event Analysis Encl + (06:19:08, 23 December 2024)
- ML20009C102 + (06:19:10, 23 December 2024)
- 05000287/LER-1981-009, Forwards LER 81-009/03L-0.Detailed Event Analysis Encl + (06:19:12, 23 December 2024)
- 05000287/LER-1980-016-03, /03L-1:on 801123,fire Detectors String B-2 Went Into Alarm Condition.Caused by Dust Buildup in Detector. Detector Cleaned & Verified Operable + (06:19:14, 23 December 2024)
- 05000287/LER-1980-016, Forwards LER 80-016/03L-1.Detailed Event Analysis Encl + (06:19:16, 23 December 2024)
- IR 05000295/1981012 + (06:19:17, 23 December 2024)
- ML20009C092 + (06:19:19, 23 December 2024)
- ML20009C088 + (06:19:21, 23 December 2024)
- ML20009C087 + (06:19:22, 23 December 2024)
- ML20009C086 + (06:19:23, 23 December 2024)
- ML20009C085 + (06:19:24, 23 December 2024)
- ML20009C084 + (06:19:25, 23 December 2024)
- ML20009C082 + (06:19:29, 23 December 2024)
- 05000369/LER-1981-040-03, /03L-0:on 810405,while in Mode 4,initial Fuel Loading,Pressure Gauges a & D Indicated Pressure W/No Actual Pressure in Steam Lines.Caused by Faulty Transmitters. Transmitters Replaced,Tested & Calibr + (06:19:31, 23 December 2024)
- 05000369/LER-1981-040, Forwards LER 81-040/03L-0.Detailed Event Analysis Encl + (06:19:33, 23 December 2024)
- 05000369/LER-1981-087-03, /03L-0:on 810518,during Initial Fuel Loading,Flow Indicator of Gross Radioactivity Monitor (EMF-31) on Waste Water Treatment Line Was Found Not Functioning.Caused by Clogged Flow Switch & Strainer.Monitor Cleaned + (06:19:34, 23 December 2024)
- ML20009C077 + (06:19:39, 23 December 2024)
- ML20009C076 + (06:19:40, 23 December 2024)
- 05000369/LER-1981-087, Forwards LER 81-087/03L-0.Detailed Event Analysis Encl + (06:19:41, 23 December 2024)
- ML20009C072 + (06:19:42, 23 December 2024)
- ML20009C070 + (06:19:43, 23 December 2024)
- ML20009C069 + (06:19:44, 23 December 2024)
- ML20009C067 + (06:19:46, 23 December 2024)
- 05000237/LER-1981-005-03, During Local Leak Rate Testing,Measured Leakage of Single Isolation Valve Exceeded Tech Specs.Caused by Normal Deterioration of Valve Seat. Valve Replaced + (06:19:47, 23 December 2024)
- ML20009C062 + (06:19:48, 23 December 2024)
- ML20009C060 + (06:19:49, 23 December 2024)
- ML20009C059 + (06:19:50, 23 December 2024)
- ML20009C058 + (06:19:51, 23 December 2024)
- 05000237/LER-1981-005, Forwards Updated LER 81-005/03X-L.Deviation Rept Encl + (06:19:53, 23 December 2024)
- ML20009C055 + (06:19:54, 23 December 2024)
- ML20009C054 + (06:19:55, 23 December 2024)
- STC-20-006, Letter Transmitting Radiogenix Generator Guidance Revision 1 + (06:19:58, 23 December 2024)
- ML20009C051 + (06:20:01, 23 December 2024)
- ML20009C050 + (06:20:02, 23 December 2024)
- ML20009C049 + (06:20:03, 23 December 2024)
- ML20009C047 + (06:20:04, 23 December 2024)
- ML20009C046 + (06:20:05, 23 December 2024)
- ML20009C043 + (06:20:09, 23 December 2024)
- ML20009C039 + (06:20:10, 23 December 2024)
- ML20009C038 + (06:20:11, 23 December 2024)
- ML20009C036 + (06:20:12, 23 December 2024)
- PM-81-584, Forwards Monthly Operating Rept for June 1981 + (06:20:13, 23 December 2024)
- ML20009C034 + (06:20:15, 23 December 2024)
- ML20009C032 + (06:20:16, 23 December 2024)