- ML20009C657 + (05:56:06, 23 December 2024)
- ML20009C656 + (05:56:07, 23 December 2024)
- ML20009C655 + (05:56:09, 23 December 2024)
- 05000280/LER-1981-025-01, /01T-0:on 810710,found Recent Analysis of Loss of Main Feedwater w/3 Reactor Coolant Pumps in Operation Requires Min of 500 Gpm of Auxiliary Feedwater Flow,Contrary to Original FSAR Criteria + (05:56:51, 23 December 2024)
- 05000369/LER-1981-098-03, /03L-0:on 810521,routine Surveillance Revealed That Periodic Channel Check of Condenser Discharge Header Isolation Valve Low Flow Interlock Was Omitted from Preventive Maint Computer Data Base.Cause Unknown + (05:58:07, 23 December 2024)
- ML20009C652 + (05:58:12, 23 December 2024)
- 05000369/LER-1981-098, Forwards LER 81-098/03L-0.Detailed Event Analysis Encl + (05:58:46, 23 December 2024)
- ML20009C649 + (05:58:52, 23 December 2024)
- ML20009C647 + (05:58:54, 23 December 2024)
- ML20009C646 + (05:58:55, 23 December 2024)
- 05000280/LER-1981-023-01, /01T-0:on 810709,TE-1-422D Delta T Protection Indicated Zero.To Investigate,Technician Returned Delta T Bistables to Normal w/TE-1-422D Still Indicating Zero.Caused by Incorrectly Wired Tc & Th Resistance Temp Detectors + (05:59:36, 23 December 2024)
- ML20009C644 + (06:00:42, 23 December 2024)
- ML20009C643 + (06:00:45, 23 December 2024)
- ML20009C640 + (06:00:47, 23 December 2024)
- 05000259/LER-1981-034-03, /03L-0:on 810616,seismic Trigger Hst C Did Not Operate During Testing.Caused by Failure of Relay in Kinemetrics Model HS-3 Horizontal Seismic Trigger Due to Moisture Condensation Inside Housing.Relay Replaced + (06:01:08, 23 December 2024)
- 05000249/LER-1981-016-03, /03L-0:on 810618,water Level Instrument Surveillance Found LIS 263-57A Tripping Above Tech Spec Levels for Low Level Scram & Low Water Level Isolation. Caused by Instrument Setpoint Drift.Setpoint Adjusted + (06:01:45, 23 December 2024)
- 05000259/LER-1981-034, Forwards LER 81-034/03L-0 + (06:02:21, 23 December 2024)
- 05000280/LER-1981-038-03, /03L-0:on 810614,one Fuel Oil Flow Path to Emergency Diesel Generator Was Inoperable.Caused by Failed Control Transformer for Fuel Oil Pump EE-P-1C.Transformer, Burned Wiring & One SOV Replaced + (06:03:02, 23 December 2024)
- 05000249/LER-1981-016, Forwards LER 81-016/03L-0 + (06:04:57, 23 December 2024)
- ML20009C632 + (06:05:02, 23 December 2024)
- 05000280/LER-1981-016-03, /03L-0:on 810615,primary Sys Chloride Concentration Exceeded Tech Specs.Apparently Caused by Personnel Working on Minor Repairs to Closure Stud Hole on Reactor Vessel Flange.All Sources of Makeup Water Checked + (06:05:35, 23 December 2024)
- ML20009C628 + (06:05:39, 23 December 2024)
- ML20009C627 + (06:05:41, 23 December 2024)
- ML20009C625 + (06:05:42, 23 December 2024)
- ML20009C624 + (06:05:43, 23 December 2024)
- AECM-81-214, Responds to Generic Ltr 81-04 Re Emergency Procedures & Training for Station Blackouts.Discusses Util Assessment of Problems & Procedures &/Or Training Programs to Resolve Problems + (06:05:45, 23 December 2024)
- ML20009C622 + (06:06:18, 23 December 2024)
- ML20009C621 + (06:06:21, 23 December 2024)
- 05000304/LER-1981-013-03, /03L-0:on 810619,steam Generator 2B Level Indication 2LI-548 Found Shifting W/Start & Stops of Containment Fan Cooler 2E.Caused by Defective Transmitter Due to Bad Force Motor + (06:06:26, 23 December 2024)
- ML20009C619 + (06:06:28, 23 December 2024)
- AECM-81-249, Confirms 810713 Telcon W/Ew Chumley Requesting Extension to Allow Applicant to Finalize Corrective Actions for Deviation Noted in IE Insp Repts 50-416/80-25 & 50-417/80-15 on 801028-31,re Fire Pump.Extension Granted Until 810814 + (06:06:31, 23 December 2024)
- 05000304/LER-1981-013, Forwards LER 81-013/03L-0 + (06:06:53, 23 December 2024)
- PNO-II-81-051, on 810711,RCS Leak Occurred,Scalding One Individual & Causing Evacuation of Lower Level of Containment.Caused by Technician Valving in Instrument Manifold W/Vent Valve on Manifold Open + (06:06:58, 23 December 2024)
- ML20009C614 + (06:06:59, 23 December 2024)
- ML20009C613 + (06:07:02, 23 December 2024)
- ML20009C612 + (06:07:03, 23 December 2024)
- ML20009C610 + (06:07:05, 23 December 2024)
- IR 05000295/1981008 + (06:07:09, 23 December 2024)
- ML20009C608 + (06:07:12, 23 December 2024)
- ML20009C606 + (06:07:14, 23 December 2024)
- ML20009C603 + (06:07:16, 23 December 2024)
- ML20009C596 + (06:07:18, 23 December 2024)
- 05000321/LER-1981-059-03, /03L-0:on 810620,delta P Was Not Established within Required Time After Mode Switch Was Placed in Run Mode.Caused by Steam Supply to Vaporizer Not Being Available Due to Slow Inerting of Drywell to Less than 4% O + (06:07:21, 23 December 2024)
- ML20009C589 + (06:07:29, 23 December 2024)
- 05000315/LER-1981-020, Special LER 81-020/01T-0 Per IE Bulletin 80-24:on 810701, Pinhole Nonessential Svc Water Leak Discovered in Integral Return Header of Instrument Room Ventilation Unit Copper Cooling Coil.Caused by Imperfection During Mfg Proces + (06:07:31, 23 December 2024)
- 05000321/LER-1981-059, Forwards LER 81-059/03L-0 + (06:07:35, 23 December 2024)
- ML20009C584 + (06:07:37, 23 December 2024)
- ML20009C579 + (06:07:47, 23 December 2024)
- 05000321/LER-1981-061-03, /03L-0:on 810629,during Steady State Operation, Offgas Hydrogen Analyzers 1N62-N009A & B Were Reported Inoperative.Caused by Analyzer a Out of Calibr.Cause of B Problem Not Stated + (06:07:50, 23 December 2024)
- 05000321/LER-1981-061, Forwards LER 81-061/03L-0 + (06:07:56, 23 December 2024)
- 05000366/LER-1981-062-03, /03L-0:on 810624,core Max Fraction of Limiting Power Density Was Not Calculated & Average Power Range Monitor Gains Not Adjusted Per Tech Specs.Caused by Evaluation Program Blocked for Calibr.Personnel Counseled + (06:08:07, 23 December 2024)