Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- LD-81-044, Forwards Vols 1-4 of Transcript Re Independent Design Review of Sys 80 Instrumentation & Controls Safety Sys + (20:52:59, 20 December 2024)
- ML20030B473 + (20:53:01, 20 December 2024)
- IR 05000160/1981001 + (20:53:03, 20 December 2024)
- ML20030B471 + (20:53:05, 20 December 2024)
- ML20030B470 + (20:53:06, 20 December 2024)
- ML20030B469 + (20:53:07, 20 December 2024)
- 05000318/LER-1981-034-03, /03L-0:on 810709,reactor Protective Sys Channel D Hipower,Thermal Margin/Low Pressure & Axial Shape Index Trip Units Were Bypassed Due to Discrepancy in T-hot.Possibly Caused by Grit Entering Connection + (20:53:09, 20 December 2024)
- ML20030B466 + (20:53:13, 20 December 2024)
- 05000318/LER-1981-034, Forwards LER 81-034/03L-0 + (20:53:15, 20 December 2024)
- ML20030B463 + (20:53:18, 20 December 2024)
- 05000259/LER-1981-006-03, /03L-0:on 810211,while Performing SI 4.2.B-57,RHR Area Cooling Fan Temp Switch 1-TS-64-68 Failed to Operate. Caused by Switch T675A1540 Failure.Switch Replaced,Calibr & 4.2.B-57 Completed + (20:53:19, 20 December 2024)
- 05000220/LER-1981-038-04, /04T-0:on 810709,white Sucker Fish Samples Collected from 810521-0528 Found to Contain Co-60 in Concentrations Slightly Higher than Control Values.Caused by Sample Contamination During Handling or Lab Analysis + (20:53:24, 20 December 2024)
- IR 05000348/1981015 + (20:53:26, 20 December 2024)
- ML20030B459 + (20:53:27, 20 December 2024)
- 05000259/LER-1981-006, Forwards LER 81-006/03L-0 + (20:53:28, 20 December 2024)
- ML20030B456 + (20:53:30, 20 December 2024)
- ML20030B455 + (20:53:31, 20 December 2024)
- 05000220/LER-1981-037-04, /04T-0:on 810709,poultry Sample Taken 3.5 Miles South of Site on 810526 Found to Contain Co-58 & Co-60 in Concentrations Exceeding Control Values.Caused by Sample Contamination During Handling or Lab Analysis + (20:53:32, 20 December 2024)
- ML20030B452 + (20:53:34, 20 December 2024)
- 05000305/LER-1980-041-01, /01X-3:on 801216,IE Bulletin 79-01B Review Identified Three Limit Switches That Are Not Sealed Installations & May Become Submerged post-LOCA.Caused by Unclear Requirement at Date of Installation + (20:53:35, 20 December 2024)
- ML20030B450 + (20:53:37, 20 December 2024)
- 05000220/LER-1981-034-03, /03L-0:on 810709,MSIV 122 Failed Stroke Test During Surveillance Test N1-ST-V4.Caused by Test Circuit Not Operating Valve to 7% Closed Position Due to Lack of Friction Between Solenoid Sys & Piston.Piston Lubricated + (20:53:38, 20 December 2024)
- ML20030B448 + (20:53:40, 20 December 2024)
- 05000220/LER-1981-034, Forwards LER 81-034/03L-0 + (20:53:41, 20 December 2024)
- ML20030B445 + (20:53:43, 20 December 2024)
- 05000305/LER-1980-041, Forwards LER 80-041/01X-3.Detailed Event Analysis Submitted + (20:53:44, 20 December 2024)
- ML20030B442 + (20:53:46, 20 December 2024)
- ML20030B439 + (20:53:48, 20 December 2024)
- ML20030B436 + (20:53:49, 20 December 2024)
- ML20030B434 + (20:53:50, 20 December 2024)
- ML20030B432 + (20:53:51, 20 December 2024)
- ML20030B429 + (20:53:52, 20 December 2024)
- ML20030B427 + (20:53:54, 20 December 2024)
- 05000327/LER-1981-084-03, /03L-0:on 810713,discovered That RCS Water Inventory Was Not Performed within 72-h Period.Caused by Inability to Achieve Steady State Required for Inventory. Startup Operations Delayed to Perform Inventory + (20:53:55, 20 December 2024)
- 05000327/LER-1981-084, Forwards LER 81-084/03L-0 + (20:53:57, 20 December 2024)
- ML20030B423 + (20:53:59, 20 December 2024)
- ML20030B422 + (20:54:01, 20 December 2024)
- ML20030B421 + (20:54:02, 20 December 2024)
- ML20030B420 + (20:54:03, 20 December 2024)
- PNO-I-81-086, on 810811,inadvertent Gaseous Release Occurred. Initial Indication Is That Release Was from Boron Recovery Sys.Manual Value Found Partially Open,Allowing Gases to Be Vented Directly to Plant Stack + (20:54:05, 20 December 2024)
- ML20030B417 + (20:54:06, 20 December 2024)
- ML20030B416 + (20:54:08, 20 December 2024)
- ML20030B415 + (20:54:09, 20 December 2024)
- ML20030B414 + (20:54:10, 20 December 2024)
- ML20030B413 + (20:54:11, 20 December 2024)
- ML20030B412 + (20:54:12, 20 December 2024)
- ML20030B410 + (20:54:13, 20 December 2024)
- ML20030B409 + (20:54:14, 20 December 2024)
- ML20030B407 + (20:54:15, 20 December 2024)
- ML20030B400 + (20:54:16, 20 December 2024)
- ML20030B395 + (20:54:17, 20 December 2024)